Electrochemical Noise Measurements of Sustained Microbially Influenced Pitting Corrosion in a Laboratory Flow Loop System

View through CrossRef
Abstract Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean-square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period. The PSD analysis results consistently demonstrated that the trends of PNL and CNL contain information that can be used to differentiate between SLP and general corrosion mechanisms. The degree of linear slope in the low-frequency portion of the PSD analysis was correlated with the SLP process. Laboratory metal coupons as well as commercial corrosion probes were tested to ensure the reproducibility and consistency of the results. The on-line monitoring capability of this new ENA method was evaluated in a bench-scale flow-loop system, which simulated microbially influenced corrosion (MIC) activity. The conditions in the test flow-loop system were controlled by the addition of microbes and different substrates to favor accelerated corrosion. The ENA results demonstrated that this in-situ corrosion monitoring system could effectively identify SLP corrosion associated with MIC, compared to a more uniform general corrosion mechanism. A reduction in SLP activity could be clearly detected by the ENA monitoring system when a corrosion inhibitor was added into one of the test loops during the corrosion testing.
Title: Electrochemical Noise Measurements of Sustained Microbially Influenced Pitting Corrosion in a Laboratory Flow Loop System
Description:
Abstract Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion.
We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques.
The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trend of the corrosion current noise level (CNL) and potential noise level (PNL).
Each CNL and PNL data point was calculated from the root-mean-square value of the ac components of current and potential fluctuation signals, which were measured simultaneously during a short time period.
The PSD analysis results consistently demonstrated that the trends of PNL and CNL contain information that can be used to differentiate between SLP and general corrosion mechanisms.
The degree of linear slope in the low-frequency portion of the PSD analysis was correlated with the SLP process.
Laboratory metal coupons as well as commercial corrosion probes were tested to ensure the reproducibility and consistency of the results.
The on-line monitoring capability of this new ENA method was evaluated in a bench-scale flow-loop system, which simulated microbially influenced corrosion (MIC) activity.
The conditions in the test flow-loop system were controlled by the addition of microbes and different substrates to favor accelerated corrosion.
The ENA results demonstrated that this in-situ corrosion monitoring system could effectively identify SLP corrosion associated with MIC, compared to a more uniform general corrosion mechanism.
A reduction in SLP activity could be clearly detected by the ENA monitoring system when a corrosion inhibitor was added into one of the test loops during the corrosion testing.

Related Results

Investigating the Effect of High Pressures and Temperatures on Corrosion Inhibition for Water-Based Muds
Investigating the Effect of High Pressures and Temperatures on Corrosion Inhibition for Water-Based Muds
Corrosion is defined as gradual degradation of metal caused by a chemical or electrochemical reaction with its environment. In oil and gas sector, components can corrode at any sta...
Integration of Localized Internal Pitting Corrosion and Flow Models
Integration of Localized Internal Pitting Corrosion and Flow Models
Abstract A model was previously developed to predict internal pitting corrosion of oil and gas pipelines. The model considers the influence of temperature, total pre...
Environmental, Processing, and Fabrication Factors Affecting Pitting Corrosion of SS316L
Environmental, Processing, and Fabrication Factors Affecting Pitting Corrosion of SS316L
The maintenance and repair of the storage canister for spent nuclear fuel are of importance to safely maintaining the national strategic fuel supply chain. End-of-life storage is a...
Comparison Between Electrochemical Noise and Electrochemical Frequency Modulation Measurements during Pitting Corrosion
Comparison Between Electrochemical Noise and Electrochemical Frequency Modulation Measurements during Pitting Corrosion
The electrochemical noise (EN) and electrochemical frequency modulation (EFM) techniques have been compared for their use to detect pitting corrosion. To do this, experiments on di...
Environmental History of Oceanic Noise Pollution
Environmental History of Oceanic Noise Pollution
The concept of “ocean noise” precedes the concept of “ocean noise pollution” by about half a century. Those seeking a body of scholarly literature on ocean noise as an environmenta...
Study Pitting Corrosion of P110 Steel by Electrochemical Frequency Modulation Technique and Coupled Multielectrode Array Sensor
Study Pitting Corrosion of P110 Steel by Electrochemical Frequency Modulation Technique and Coupled Multielectrode Array Sensor
By using the electrochemical frequency modulation (EFM) technique, coupled multielectrode array sensor (CMAS), and other corrosion research techniques, the pitting corrosion behavi...
Characterization of Biofilm Formation and Coating Degradation By Electrochemical Impedance Spectroscopy
Characterization of Biofilm Formation and Coating Degradation By Electrochemical Impedance Spectroscopy
Recent findings showed severe localized corrosion of submerged steel bridge piles in a Florida bridge and was associated with microbial activity in presence of marine foulers (Perm...
Corrosion Monitoring by Electrochemical Noise Probes in a Purified Terephthalic Acid Production Plant
Corrosion Monitoring by Electrochemical Noise Probes in a Purified Terephthalic Acid Production Plant
Abstract An on-line electrochemical noise corrosion-monitoring program was commissioned in a Purified Terephthalic Acid (PTA) production plant. The program was initi...