Javascript must be enabled to continue!
A high intensity H2+ multicusp ion source for the isotope decay-at-rest experiment, IsoDAR
View through CrossRef
The Isotope Decay-At-Rest (IsoDAR) experimental program aims to decisively test the sterile neutrino hypothesis. In essence, it is a novel cyclotron based neutrino factory that will improve the frontiers in both high-intensity cyclotrons and electron flavor anti-neutrino sources. By using a source in which the usual H− ions are replaced with the more tightly bound H2+ ions, we can negate the effects of Lorentz stripping in a cyclotron, reduce the overall perveance due to the space-charge effect, and deliver twice the number of protons per nuclei on target. To produce the H2+, we are currently developing a dedicated multicusp ion source, MIST-1 (generation-1 Multicusp Ion Source Technologies at MIT), and a low-energy beam transport system for the IsoDAR cyclotron. This will increase the overall H2+ current leading up to the cyclotron and improve the emittance of the beam injected into the cyclotron.
Title: A high intensity H2+ multicusp ion source for the isotope decay-at-rest experiment, IsoDAR
Description:
The Isotope Decay-At-Rest (IsoDAR) experimental program aims to decisively test the sterile neutrino hypothesis.
In essence, it is a novel cyclotron based neutrino factory that will improve the frontiers in both high-intensity cyclotrons and electron flavor anti-neutrino sources.
By using a source in which the usual H− ions are replaced with the more tightly bound H2+ ions, we can negate the effects of Lorentz stripping in a cyclotron, reduce the overall perveance due to the space-charge effect, and deliver twice the number of protons per nuclei on target.
To produce the H2+, we are currently developing a dedicated multicusp ion source, MIST-1 (generation-1 Multicusp Ion Source Technologies at MIT), and a low-energy beam transport system for the IsoDAR cyclotron.
This will increase the overall H2+ current leading up to the cyclotron and improve the emittance of the beam injected into the cyclotron.
Related Results
7
th
International Symposium on Enabling Technologies for Life Sciences (ETP)
7
th
International Symposium on Enabling Technologies for Life Sciences (ETP)
The seventh in the series of ETP Symposia (see
Rapid Communications in Mass Spectrometry
2012,
26
, ...
Resolving the Hf-Nd paradox of early Earth crust-mantle evolution
Resolving the Hf-Nd paradox of early Earth crust-mantle evolution
<p>One of the fundamental tenets of geochemistry is that the Earth&#8217;s crust has been extracted from the mantle creating a crustal reservoir enriched&...
3D simulation optimization and design of multicusp ion source
3D simulation optimization and design of multicusp ion source
In this paper, a permanent magnet of multicusp ion source is calculated in theory, using the binary collision model to deal with coulomb collision between electrons. Collision betw...
Preliminary design of a RFQ direct injection scheme for the IsoDAR high intensity H2+ cyclotron
Preliminary design of a RFQ direct injection scheme for the IsoDAR high intensity H2+ cyclotron
IsoDAR (Isotope Decay-At-Rest) is a novel experiment designed to measure neutrino oscillations through ν̄e disappearance, thus providing a definitive search for sterile neutrinos. ...
Chemical pre-intercalation synthesis approach for novel layered cathode materials for Li-ion and beyond Li-ion batteries
Chemical pre-intercalation synthesis approach for novel layered cathode materials for Li-ion and beyond Li-ion batteries
Beyond-lithium ion (BLI) alkali ion-based batteries are rising in interest among researchers because of their utilization of more abundant, cost-effective charge carriers, includin...
Development of series H− multicusp ion source at China Institute of Atomic Energy
Development of series H− multicusp ion source at China Institute of Atomic Energy
The development of H− multicusp ion sources has been carried out at China Institute of Atomic Energy (CIAE) for more than ten years. The first H− ion source with 5.2 mA was made in...
Evaluation of decay times in coupled spaces: Bayesian decay model selection
Evaluation of decay times in coupled spaces: Bayesian decay model selection
This paper applies Bayesian probability theory to determination of the decay times in coupled spaces. A previous paper [N. Xiang and P. M. Goggans, J. Acoust. Soc. Am. 110, 1415–14...
Axisymmetric antidynamo theorems in compressible non-uniform conducting fluids
Axisymmetric antidynamo theorems in compressible non-uniform conducting fluids
Abstract
This paper considers magnetic fields generated by dynamo action in electrically conducting fluids under axisymmetric but otherwise very general non-stead...

