Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Standardizing Corneal Transplantation Records Using openEHR: Case Study

View through CrossRef
Background Corneal transplantation, also known as keratoplasty, is a widely performed surgical procedure that aims to restore vision in patients with corneal damage. The success of corneal transplantation relies on the accurate and timely management of patient information, which can be enhanced using electronic health records (EHRs). However, conventional EHRs are often fragmented and lack standardization, leading to difficulties in information access and sharing, increased medical errors, and decreased patient safety. In the wake of these problems, there is a growing demand for standardized EHRs that can ensure the accuracy and consistency of patient data across health care organizations. Objective This paper proposes the use of openEHR structures for standardizing corneal transplantation records. The main objective of this research was to improve the quality and interoperability of EHRs in corneal transplantation, making it easier for health care providers to capture, share, and analyze clinical information. Methods A series of sequential steps were carried out in this study to implement standardized clinical records using openEHR specifications. These specifications furnish a methodical approach that ascertains the development of high-quality clinical records. In broad terms, the methodology followed encompasses the conduction of meetings with health care professionals and the modeling of archetypes, templates, forms, decision rules, and work plans. Results This research resulted in a tailored solution that streamlines health care delivery and meets the needs of medical professionals involved in the corneal transplantation process while seamlessly aligning with contemporary clinical practices. The proposed solution culminated in the successful integration within a Portuguese hospital of 3 key components of openEHR specifications: forms, Decision Logic Modules, and Work Plans. A statistical analysis of data collected from May 1, 2022, to March 31, 2023, allowed for the perception of the use of the new technologies within the corneal transplantation workflow. Despite the completion rate being only 63.9% (530/830), which can be explained by external factors such as patient health and availability of donor organs, there was an overall improvement in terms of task control and follow-up of the patients’ clinical process. Conclusions This study shows that the adoption of openEHR structures represents a significant step forward in the standardization and optimization of corneal transplantation records. It offers a detailed demonstration of how to implement openEHR specifications and highlights the different advantages of standardizing EHRs in the field of corneal transplantation. Furthermore, it serves as a valuable reference for researchers and practitioners who are interested in advancing and improving the exploitation of EHRs in health care.
Title: Standardizing Corneal Transplantation Records Using openEHR: Case Study
Description:
Background Corneal transplantation, also known as keratoplasty, is a widely performed surgical procedure that aims to restore vision in patients with corneal damage.
The success of corneal transplantation relies on the accurate and timely management of patient information, which can be enhanced using electronic health records (EHRs).
However, conventional EHRs are often fragmented and lack standardization, leading to difficulties in information access and sharing, increased medical errors, and decreased patient safety.
In the wake of these problems, there is a growing demand for standardized EHRs that can ensure the accuracy and consistency of patient data across health care organizations.
Objective This paper proposes the use of openEHR structures for standardizing corneal transplantation records.
The main objective of this research was to improve the quality and interoperability of EHRs in corneal transplantation, making it easier for health care providers to capture, share, and analyze clinical information.
Methods A series of sequential steps were carried out in this study to implement standardized clinical records using openEHR specifications.
These specifications furnish a methodical approach that ascertains the development of high-quality clinical records.
In broad terms, the methodology followed encompasses the conduction of meetings with health care professionals and the modeling of archetypes, templates, forms, decision rules, and work plans.
Results This research resulted in a tailored solution that streamlines health care delivery and meets the needs of medical professionals involved in the corneal transplantation process while seamlessly aligning with contemporary clinical practices.
The proposed solution culminated in the successful integration within a Portuguese hospital of 3 key components of openEHR specifications: forms, Decision Logic Modules, and Work Plans.
A statistical analysis of data collected from May 1, 2022, to March 31, 2023, allowed for the perception of the use of the new technologies within the corneal transplantation workflow.
Despite the completion rate being only 63.
9% (530/830), which can be explained by external factors such as patient health and availability of donor organs, there was an overall improvement in terms of task control and follow-up of the patients’ clinical process.
Conclusions This study shows that the adoption of openEHR structures represents a significant step forward in the standardization and optimization of corneal transplantation records.
It offers a detailed demonstration of how to implement openEHR specifications and highlights the different advantages of standardizing EHRs in the field of corneal transplantation.
Furthermore, it serves as a valuable reference for researchers and practitioners who are interested in advancing and improving the exploitation of EHRs in health care.

Related Results

Standardizing Corneal Transplantation Records Using openEHR: Case Study (Preprint)
Standardizing Corneal Transplantation Records Using openEHR: Case Study (Preprint)
BACKGROUND Corneal transplantation, also known as keratoplasty, is a widely performed surgical procedure that aims to restore vision in patients with cornea...
CORNEAL TRANSPLANTATION
CORNEAL TRANSPLANTATION
Corneal transplantation is an ophthalmic surgery that aims to restore vision in patients with corneal diseases. Advances in transplantation techniques and in the treatment of rejec...
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
(English) The cornea is the outermost layer of the eye, essential for vision as it provides protection and contributes 80% of the eye’s refractive power. Its transparency and lack ...
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
BackgroundKeratoconus (KC) is an ectatic corneal disorder characterized by progressive corneal thinning with myopic astigmatism. Intrastromal corneal ring segments (ICRS) have been...
Effects of TGFB1 and 17 B estradiol on corneal stiffness and thickness
Effects of TGFB1 and 17 B estradiol on corneal stiffness and thickness
Background: Impaired corneal stiffness and transparency are the hallmarks of some of the leading global causes of corneal blindness diseases, such as keratoconus (KCN) which is cha...
Repeatability and reproducibility of Keratograph 5M corneal topography
Repeatability and reproducibility of Keratograph 5M corneal topography
Background Corneal topography is an important diagnostic tool and highly repeatable and reproducible topographic devices are essential in eye care practice. Placido ...

Back to Top