Diagnostic performance of electrical cardiometry (ICON®) parameters in predicting fluid responsiveness in critically ill pediatric patients

View through CrossRef
Background  Fluid resuscitation with appropriate and adequate amounts is very important in treating critically ill children, so reliable hemodynamic monitoring methods are needed to prevent fluid overload. Contractility index (ICON) is a novel, non-invasive index of left ventricular (LV) function, and contractility related to the electrical cardiometry device (ICON®). ICON® offers a non-invasive hemodynamic monitoring method to assess volume status, but its validity in predicting fluid response in the Indonesian pediatric population remains unknown. Objective To determine the diagnostic performance of ICON-derived parameters, especially change of cardiac output (ΔCO) and change in contractility index (ΔICON), in predicting fluid response, using change of stroke volume (ΔSV)  as a reference standard. Methods A cross-sectional study was conducted in pediatric emergency and intensive care settings. Children aged 1 month to 18 years requiring fluid resuscitation were included. Hemodynamic parameters were measured using ICON® before and after a 10 mL/kg fluid bolus of crystalloid. Fluid responsiveness was defined as a >10% increase in ΔSV. Changes in parameters were analyzed using paired statistical tests. ROC analysis was used to assess the diagnostic accuracy of CO and ICON. Results Sixty-three subjects were analyzed. Significant median changes were observed after fluid bolus administration based on pre- and post-bolus comparison in change of heart rate (ΔHR: –8 bpm, P<0.001), change of systolic blood pressure (ΔSBP: +3 mmHg, P=0.042), change of diastolic blood pressure (ΔDBP: +2 mmHg, P=0.012), change of mean arterial pressure (ΔMAP: +0.67 mmHg, P=0.009). The ROC analysis showed that CO had the highest AUC (0.878), with a cut-off of 5.35%, sensitivity of 78.3%, and specificity of 87.2%. The ICON showed moderate accuracy (AUC 0.757), with a 0.45% cut-off, 69.6% sensitivity, and 71.8% specificity. Conclusion Electrical cardiometry (ICON®) demonstrated measurable changes in objective hemodynamic parameters following fluid bolus administration in critically ill children. Among ICON-derived parameters, a 5.35% increase in CO showed the best predictive performance for fluid responsiveness, while ICON showed moderate diagnostic value. These findings support the clinical utility of electrical cardiometry as a non-invasive tool to guide volume management in pediatric critical care.
Title: Diagnostic performance of electrical cardiometry (ICON®) parameters in predicting fluid responsiveness in critically ill pediatric patients
Description:
Background  Fluid resuscitation with appropriate and adequate amounts is very important in treating critically ill children, so reliable hemodynamic monitoring methods are needed to prevent fluid overload.
Contractility index (ICON) is a novel, non-invasive index of left ventricular (LV) function, and contractility related to the electrical cardiometry device (ICON®).
ICON® offers a non-invasive hemodynamic monitoring method to assess volume status, but its validity in predicting fluid response in the Indonesian pediatric population remains unknown.
Objective To determine the diagnostic performance of ICON-derived parameters, especially change of cardiac output (ΔCO) and change in contractility index (ΔICON), in predicting fluid response, using change of stroke volume (ΔSV)  as a reference standard.
Methods A cross-sectional study was conducted in pediatric emergency and intensive care settings.
Children aged 1 month to 18 years requiring fluid resuscitation were included.
Hemodynamic parameters were measured using ICON® before and after a 10 mL/kg fluid bolus of crystalloid.
Fluid responsiveness was defined as a >10% increase in ΔSV.
Changes in parameters were analyzed using paired statistical tests.
ROC analysis was used to assess the diagnostic accuracy of CO and ICON.
Results Sixty-three subjects were analyzed.
Significant median changes were observed after fluid bolus administration based on pre- and post-bolus comparison in change of heart rate (ΔHR: –8 bpm, P<0.
001), change of systolic blood pressure (ΔSBP: +3 mmHg, P=0.
042), change of diastolic blood pressure (ΔDBP: +2 mmHg, P=0.
012), change of mean arterial pressure (ΔMAP: +0.
67 mmHg, P=0.
009).
The ROC analysis showed that CO had the highest AUC (0.
878), with a cut-off of 5.
35%, sensitivity of 78.
3%, and specificity of 87.
2%.
The ICON showed moderate accuracy (AUC 0.
757), with a 0.
45% cut-off, 69.
6% sensitivity, and 71.
8% specificity.
Conclusion Electrical cardiometry (ICON®) demonstrated measurable changes in objective hemodynamic parameters following fluid bolus administration in critically ill children.
Among ICON-derived parameters, a 5.
35% increase in CO showed the best predictive performance for fluid responsiveness, while ICON showed moderate diagnostic value.
These findings support the clinical utility of electrical cardiometry as a non-invasive tool to guide volume management in pediatric critical care.

Related Results

Pediatric Pilonidal Sinus Disease: A Single-Center Cohort Study of Clinical and Surgical Outcomes
Pediatric Pilonidal Sinus Disease: A Single-Center Cohort Study of Clinical and Surgical Outcomes
Abstract Introduction: Pilonidal sinus disease is increasingly recognized in the pediatric population, yet evidence on its clinical characteristics and surgical outcomes in childre...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
BACKGROUND: A workforce analysis was conducted to predict whether the projected future supply of pediatric anesthesiologists is balanced with the requirements o...
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
BACKGROUND: The geographic relationship between pediatric anesthesiologists and the pediatric population has potentially important clinical and policy implicati...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Dynamic parameters for fluid responsiveness in mechanically ventilated children: A systematic review
Dynamic parameters for fluid responsiveness in mechanically ventilated children: A systematic review
ObjectiveFluid administration is the initial step of treatment of unstable pediatric patients. Evaluation of fluid responsiveness is crucial in mechanically ventilated children to ...
Suffering of Patients with Neurogenic Thoracic Outlet Syndrome (TOS); The First Qualitative study in TOS
Suffering of Patients with Neurogenic Thoracic Outlet Syndrome (TOS); The First Qualitative study in TOS
Abstract Background Diagnosis of neurogenic thoracic outlet syndrome (nTOS) is hindered by symptom overlap with cervical radiculopathy, carpal tunnel syndrome, or psychosomatic dis...

Back to Top