Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Multimodal MR Imaging for quantification of brain lipid in mice at 9.4T

View through CrossRef
ABSTRACT Background Advanced MR imaging techniques like steady state Nuclear Overhauser enhancement (ssNOE), transient NOE (tNOE), and myelin water fraction (MWF) provide a non-invasive way to assess the biochemical and structural integrity of brain tissue. Their sensitivity to endogenous lipids and macromolecules allows for the early detection of neuropathological changes, making them valuable tools in studying brain health and disease progression. In this study, we systematically evaluate the repeatability and sensitivity of NOE MTR , tNOE, and MWF for quantifying lipid and myelin content in the brains of wild-type (WT) mice, correlating the results with immunohistochemistry (IHC). Methods Five 6-month-old C57BL6/J mice were imaged using 3D-NOE, and four mice underwent imaging with 2D tNOE and MWF across four repeated sessions using a 9.4T Scanner. For ssNOE imaging, CEST-weighted images at 56 frequency offsets were acquired using B 1rms of 1.0 μT and 3s saturation duration. For tNOE, 52 offsets were acquired with a hyperbolic secant inversion pulse (bandwidth = 400Hz, duration = 44ms) and a mixing time of 200ms. For MWF, a multi-echo spin-echo (MESE) sequence was acquired with 40 evenly spaced echoes from 5.5ms to 200ms. For both ssNOE and tNOE, B 0 correction was performed using WASSR. Repeatability was quantified using intra- and inter-subject coefficients of variation (COV%). Pearson correlation was performed to see the association between imaging matrices and IHC measures, Luxol fast blue (LFB) stained sections, and myelin basic protein (MBP). Results All techniques demonstrated high repeatability across the whole brain (WB) and selected regions of interest (ROIs). Whole-brain intra-subject COV% for NOE MTR ranged from 1.92% to 3.40%, with corresponding inter-subject COVs of 1.50%. tNOE exhibited improved intra-subject repeatability with COVs ranging from 0.75% to 5.57%, but a reduced inter-subject COV of 2.97%. MWF imaging showed the highest stability overall, with an intra-subject COV ranging from 0.47% to 2.03% and an inter-subject COV of 0.75%. Visually, tNOE offers superior contrast in myelin-rich areas compared to NOE MTR and MWF imaging, showing greater sensitivity to myelinated regions. tNOE strongly correlates with histological markers: r = 0.83 with MBP staining and r = 0.72 with LFB staining (both p < 0.001). MWF and NOE MTR showed correlations with MBP (r = 0.63 and r = 0.57, respectively). Conclusion NOE MTR , tNOE, and MWF imaging are reliable and repeatable methods for quantifying macromolecules in the brain. Among these, tNOE emerges as the most sensitive for detecting myelin lipids as confirmed by histological validation. These findings highlight the translational potential of tNOE for studying demyelinating disorders and neurodegenerative diseases.
Title: Multimodal MR Imaging for quantification of brain lipid in mice at 9.4T
Description:
ABSTRACT Background Advanced MR imaging techniques like steady state Nuclear Overhauser enhancement (ssNOE), transient NOE (tNOE), and myelin water fraction (MWF) provide a non-invasive way to assess the biochemical and structural integrity of brain tissue.
Their sensitivity to endogenous lipids and macromolecules allows for the early detection of neuropathological changes, making them valuable tools in studying brain health and disease progression.
In this study, we systematically evaluate the repeatability and sensitivity of NOE MTR , tNOE, and MWF for quantifying lipid and myelin content in the brains of wild-type (WT) mice, correlating the results with immunohistochemistry (IHC).
Methods Five 6-month-old C57BL6/J mice were imaged using 3D-NOE, and four mice underwent imaging with 2D tNOE and MWF across four repeated sessions using a 9.
4T Scanner.
For ssNOE imaging, CEST-weighted images at 56 frequency offsets were acquired using B 1rms of 1.
0 μT and 3s saturation duration.
For tNOE, 52 offsets were acquired with a hyperbolic secant inversion pulse (bandwidth = 400Hz, duration = 44ms) and a mixing time of 200ms.
For MWF, a multi-echo spin-echo (MESE) sequence was acquired with 40 evenly spaced echoes from 5.
5ms to 200ms.
For both ssNOE and tNOE, B 0 correction was performed using WASSR.
Repeatability was quantified using intra- and inter-subject coefficients of variation (COV%).
Pearson correlation was performed to see the association between imaging matrices and IHC measures, Luxol fast blue (LFB) stained sections, and myelin basic protein (MBP).
Results All techniques demonstrated high repeatability across the whole brain (WB) and selected regions of interest (ROIs).
Whole-brain intra-subject COV% for NOE MTR ranged from 1.
92% to 3.
40%, with corresponding inter-subject COVs of 1.
50%.
tNOE exhibited improved intra-subject repeatability with COVs ranging from 0.
75% to 5.
57%, but a reduced inter-subject COV of 2.
97%.
MWF imaging showed the highest stability overall, with an intra-subject COV ranging from 0.
47% to 2.
03% and an inter-subject COV of 0.
75%.
Visually, tNOE offers superior contrast in myelin-rich areas compared to NOE MTR and MWF imaging, showing greater sensitivity to myelinated regions.
tNOE strongly correlates with histological markers: r = 0.
83 with MBP staining and r = 0.
72 with LFB staining (both p < 0.
001).
MWF and NOE MTR showed correlations with MBP (r = 0.
63 and r = 0.
57, respectively).
Conclusion NOE MTR , tNOE, and MWF imaging are reliable and repeatable methods for quantifying macromolecules in the brain.
Among these, tNOE emerges as the most sensitive for detecting myelin lipids as confirmed by histological validation.
These findings highlight the translational potential of tNOE for studying demyelinating disorders and neurodegenerative diseases.

Related Results

Brain Organoids, the Path Forward?
Brain Organoids, the Path Forward?
Photo by Maxim Berg on Unsplash INTRODUCTION The brain is one of the most foundational parts of being human, and we are still learning about what makes humans unique. Advancements ...
[RETRACTED] Gro-X Brain Reviews - Is Gro-X Brain A Scam? v1
[RETRACTED] Gro-X Brain Reviews - Is Gro-X Brain A Scam? v1
[RETRACTED]➢Item Name - Gro-X Brain➢ Creation - Natural Organic Compound➢ Incidental Effects - NA➢ Accessibility - Online➢ Rating - ⭐⭐⭐⭐⭐➢ Click Here To Visit - Official Website - ...
Renal tubular (pro)renin receptor deletion does not protect against kidney injury in db/db mice
Renal tubular (pro)renin receptor deletion does not protect against kidney injury in db/db mice
Background: The (pro)renin receptor (PRR) is a multifunctional protein implicated in blood pressure regulation and kidney fibrosis. Previous studies report enhanced PRR expression ...
GW24-e2259 Evaluation of atherosclerosis in low density lipoprotein receptor defect mice by ultrasound biomicroscopy
GW24-e2259 Evaluation of atherosclerosis in low density lipoprotein receptor defect mice by ultrasound biomicroscopy
Objectives Low density lipoprotein receptor defect mice model by transgenetic technology was used to detect atherosclerosis by Ultrasound Biology (UBM). And evalu...
Characterization of Hematopoiesis in Tp53 R172H Mutant Mice
Characterization of Hematopoiesis in Tp53 R172H Mutant Mice
Abstract In a cohort of 150 patients with myelodysplastic syndrome (MDS), the most common adult myeloid malignancy, missense mutations in TP53 were more common than ...
Supplementary Data from Targeted BiTE Expression by an Oncolytic Vector Augments Therapeutic Efficacy Against Solid Tumors
Supplementary Data from Targeted BiTE Expression by an Oncolytic Vector Augments Therapeutic Efficacy Against Solid Tumors
<p>Supplementary Methods, Supplementary Figures S1-S15 Fig. S1. Purification and binding specificity of MV-encoded BiTEs. (A) Purification of MV-expressed BiTEs. Vero cells w...
Effects of Disruption of The Plasminogen Gene on Thrombosis, Growth, and Health in Mice
Effects of Disruption of The Plasminogen Gene on Thrombosis, Growth, and Health in Mice
Background Circumstantial evidence suggests that the plasminogen/plasmin system plays a role in many biological processes, including hemostasis, cell migration, and dev...
Multimodal Emotion Recognition and Human Computer Interaction for AI-Driven Mental Health Support (Preprint)
Multimodal Emotion Recognition and Human Computer Interaction for AI-Driven Mental Health Support (Preprint)
BACKGROUND Mental health has become one of the most urgent global health issues of the twenty-first century. The World Health Organization (WHO) reports tha...

Back to Top