Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effect of light intensity on linear shrinkage of photo‐activated composite resins during setting

View through CrossRef
summary  The purpose of this investigation was to examine the effects of light intensity on linear shrinkage of photo‐activated composite resins during setting. The materials used were four commercially available photo‐activated composite resins. Three light‐irradiation instruments were selected and prepared so as to obtain four light intensities (200, 480, 800 and 1600 mW cm−2). The linear shrinkage during setting was examined 10 min after light irradiation using a trial balance plastometer, and the specimen thickness was 2·0 mm for all materials. The depth of cure was examined according to the test method described in the International Organization for Standardization (ISO/FDIS 4049: 2000(E)). In measuring the linear shrinkage 60 s from the start of light irradiation for 10 s, there was a significant correlation (r = 0·89–0·94) between the amount of linear shrinkage and the light intensity: an increase in light intensity produced a greater linear shrinkage. Furthermore, there was a significant correlation (r = 0·92–1·0) between the linear shrinkage and the irradiation time: an increase in irradiation time resulted in a greater linear shrinkage. Values of the depth of cure ranged from 1·69 to 3·75 mm.
Title: Effect of light intensity on linear shrinkage of photo‐activated composite resins during setting
Description:
summary  The purpose of this investigation was to examine the effects of light intensity on linear shrinkage of photo‐activated composite resins during setting.
The materials used were four commercially available photo‐activated composite resins.
Three light‐irradiation instruments were selected and prepared so as to obtain four light intensities (200, 480, 800 and 1600 mW cm−2).
The linear shrinkage during setting was examined 10 min after light irradiation using a trial balance plastometer, and the specimen thickness was 2·0 mm for all materials.
The depth of cure was examined according to the test method described in the International Organization for Standardization (ISO/FDIS 4049: 2000(E)).
In measuring the linear shrinkage 60 s from the start of light irradiation for 10 s, there was a significant correlation (r = 0·89–0·94) between the amount of linear shrinkage and the light intensity: an increase in light intensity produced a greater linear shrinkage.
Furthermore, there was a significant correlation (r = 0·92–1·0) between the linear shrinkage and the irradiation time: an increase in irradiation time resulted in a greater linear shrinkage.
Values of the depth of cure ranged from 1·69 to 3·75 mm.

Related Results

Investigation on temperature shrinkage characteristics of the combined structure in asphalt pavement
Investigation on temperature shrinkage characteristics of the combined structure in asphalt pavement
The temperature shrinkage of materials primarily causes transverse cracking. Current research mainly focuses on the temperature shrinkage of single materials. This work aims to ana...
Mathematical Modelling of Heat and Mass Transfer during Jackfruit Drying Considering Shrinkage
Mathematical Modelling of Heat and Mass Transfer during Jackfruit Drying Considering Shrinkage
Shrinkage is an obvious phenomenon that occurs when drying plant-based food materials, and it has a crucial influence on heat–mass transfer mechanisms, energy consumption in drying...
Hydrocarbon Resins
Hydrocarbon Resins
AbstractHydrocarbon resins are low molecular weight thermoplastic polymers synthesized via the polymerization of coal‐tar fractions, cracked petroleum distillates, terpenes, or pur...
Miscellaneous Organic Polymers
Miscellaneous Organic Polymers
AbstractPolymers are advanced materials composed of many repeating monomer units; organic polymers are polymers that essentially contain carbon atoms in the backbone. Significant v...
Shrinkage of Renal Tissue after Impregnation via the Cold Biodur Plastination Technique
Shrinkage of Renal Tissue after Impregnation via the Cold Biodur Plastination Technique
AbstractThorough dehydration is a key for good plastination and invariably it leads to shrinkage. Shrinkage during plastination has been studied to lesser extent. Shrinkage was stu...
Specifying Shrinkage Limited Cement (Type SL)
Specifying Shrinkage Limited Cement (Type SL)
Abstract The Australian Standard AS 3972 specifies the maximum limit of 750 microstrain for the 28-day mortar drying shrinkage of samples prepared with shrinkage lim...

Back to Top