Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Simplified VIV Response of Partially Strake-Covered Pipe Spans

View through CrossRef
A simplified method for the fatigue assessment for partially strake-covered pipeline spans is provided and calibrated so that for the bare pipe case it is consistent with the current DNVGL Recommended Practice (DNVGL-RP-F105). It is based on a Rayleigh-Ritz approximation using the first undamped mode shape. In that sense it is equivalent to a single-mode analysis using Shear7, except that it accounts for frequency-dependent added mass, and the formulation is presented in a compact and convenient non-dimensional form. The method presented may also be considered a simplification of that in Vivana in that it does not account for propagating wave effects, and is therefore named “Sivana”.Like any frequency-domain method Sivana is based on the assumption of harmonic response. This requires excitation and added mass functions that define a harmonic hydrodynamic force as a function of the harmonic motion. On the other hand, current practice by DNVGL-RP-F105 is based on a response function, which gives VIV amplitude as function of reduced velocity and the Scruton mass-damping parameter Ks. To bridge this gap, an inversion technique is developed whereby the excitation function for bare pipe is derived from the DNVGL-RP-F105 response function, such that for bare pipe the Sivana calculation will lead to the same response amplitudes as DNVGL-RP-F105. The Sivana method is illustrated by an example involving a single span with different degrees of strake coverage centered at midspan.Although the Sivana method might be considered a natural and straight-forward extension of current span assessment practice to include partial strake coverage, caution is in order for certain approximations in the DNVGL-RP-F105 response function may be less appropriate for the use in this paper, than for the use envisioned by the developers of the DNVGL guidance.
Title: Simplified VIV Response of Partially Strake-Covered Pipe Spans
Description:
A simplified method for the fatigue assessment for partially strake-covered pipeline spans is provided and calibrated so that for the bare pipe case it is consistent with the current DNVGL Recommended Practice (DNVGL-RP-F105).
It is based on a Rayleigh-Ritz approximation using the first undamped mode shape.
In that sense it is equivalent to a single-mode analysis using Shear7, except that it accounts for frequency-dependent added mass, and the formulation is presented in a compact and convenient non-dimensional form.
The method presented may also be considered a simplification of that in Vivana in that it does not account for propagating wave effects, and is therefore named “Sivana”.
Like any frequency-domain method Sivana is based on the assumption of harmonic response.
This requires excitation and added mass functions that define a harmonic hydrodynamic force as a function of the harmonic motion.
On the other hand, current practice by DNVGL-RP-F105 is based on a response function, which gives VIV amplitude as function of reduced velocity and the Scruton mass-damping parameter Ks.
To bridge this gap, an inversion technique is developed whereby the excitation function for bare pipe is derived from the DNVGL-RP-F105 response function, such that for bare pipe the Sivana calculation will lead to the same response amplitudes as DNVGL-RP-F105.
The Sivana method is illustrated by an example involving a single span with different degrees of strake coverage centered at midspan.
Although the Sivana method might be considered a natural and straight-forward extension of current span assessment practice to include partial strake coverage, caution is in order for certain approximations in the DNVGL-RP-F105 response function may be less appropriate for the use in this paper, than for the use envisioned by the developers of the DNVGL guidance.

Related Results

The Effectiveness of Helical Strakes in the Suppression of High-Mode-Number VIV
The Effectiveness of Helical Strakes in the Suppression of High-Mode-Number VIV
Abstract Triple helical strakes can play an important role in the suppression of VIV on offshore platforms. This paper will present results of two field experimen...
Advancement of Spar VIV Prediction
Advancement of Spar VIV Prediction
Abstract Vortex Induced Vibration (VIV) of spar hulls is an essential operational issue in high current environments and an important consideration for mooring an...
Pragmatic Riser VIV Analysis
Pragmatic Riser VIV Analysis
Abstract Drilling and production risers experiencing vortex-induced vibrations (VIV) may adversely impact operations in two ways: by increasing deflection due to ...
Riser VIV Axial Fatigue Analysis and Mathieu instability Mitigation
Riser VIV Axial Fatigue Analysis and Mathieu instability Mitigation
Abstract Currently, the so-called state-of-practice approaches are commonly used inriser VIV analysis. DNV RP F204 has indicated that riser axial stress fatiguedu...
Modelling and Simulation of Vortex-Induced Vibrations in Wind Turbines
Modelling and Simulation of Vortex-Induced Vibrations in Wind Turbines
This thesis investigates vortex-induced vibrations (VIV) in wind turbine towers and blades. It addresses the challenges posed by this complex aeroelastic phenomenon through two com...
Optimized Design of Pipe-in-Pipe Systems
Optimized Design of Pipe-in-Pipe Systems
Abstract Deepwater subsea developments must address the flow assurance issues and increasingly these are forming a more critical part of the design. Pipe-in-pipe ...
Cumulative Fatigue Damage of Drill Pipe in Dog-Legs
Cumulative Fatigue Damage of Drill Pipe in Dog-Legs
Abstract Rotating drill pipe passing through dog-legs suffers fatigue damage due to cyclic bending stresses. Curves of the cumulative fatigue damage incurred in e...
Consistent VIV Assessment Methodology for Unbonded Flexible Risers
Consistent VIV Assessment Methodology for Unbonded Flexible Risers
One main objective of assessing vortex-induced vibration (VIV) in deep-water (1000 m) riser design analysis is to determine the VIV fatigue damage. Whilst the VIV assessment method...

Back to Top