Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Transformerless DSTATCOM Based on Cross-Switched Multilevel Inverter for Grid Voltage Regulation

View through CrossRef
In this paper, a transformerless distribution static synchronous compensator (DSTATCOM) based on the cross-switched (CS) multilevel inverter (CSMLI) is introduced. In comparison with the well-known cascaded h-bridge (CHB) topology, CS inverter produces higher number of voltage levels using fewer number of power components. Since CS inverter produces ac side voltage with high quality and has the ability to work at high voltage and power levels, the proposed CS-DSTATCOM is directly connected to the distribution grid without the need for a transformer. In the proposed CS-DSTATCOM, all the dc sources are replaced with dc capacitors. In this paper, an effective voltage balancing control scheme is proposed to keep the capacitors voltages balanced in the CS structure. The control scheme balances the capacitors voltages in two levels, i.e., inter-cell and within-cell level. On the other hand, the over-voltage and under-voltage phenomena are of the most common power quality (PQ) issues in distribution grids. The proposed DSTATCOM is able to cope with these issues by exchanging reactive power with the grid. Applying the CSMLI in the DSTATCOM structure as well as the capacitors voltage balancing methods are the main novelties of the paper. Also, the capacitors values are considered to be different (which is unavoidable in practice) while their voltages are balanced using the proposed voltage balancing methods. In this paper, a CS-DSTATCOM has been designed for 11 kV distribution grid and several simulation results are provided in the MATLAB/Simulink environment which validate the feasibility and performance of the proposed CS-DSTATCOM.
Title: A Transformerless DSTATCOM Based on Cross-Switched Multilevel Inverter for Grid Voltage Regulation
Description:
In this paper, a transformerless distribution static synchronous compensator (DSTATCOM) based on the cross-switched (CS) multilevel inverter (CSMLI) is introduced.
In comparison with the well-known cascaded h-bridge (CHB) topology, CS inverter produces higher number of voltage levels using fewer number of power components.
Since CS inverter produces ac side voltage with high quality and has the ability to work at high voltage and power levels, the proposed CS-DSTATCOM is directly connected to the distribution grid without the need for a transformer.
In the proposed CS-DSTATCOM, all the dc sources are replaced with dc capacitors.
In this paper, an effective voltage balancing control scheme is proposed to keep the capacitors voltages balanced in the CS structure.
The control scheme balances the capacitors voltages in two levels, i.
e.
, inter-cell and within-cell level.
On the other hand, the over-voltage and under-voltage phenomena are of the most common power quality (PQ) issues in distribution grids.
The proposed DSTATCOM is able to cope with these issues by exchanging reactive power with the grid.
Applying the CSMLI in the DSTATCOM structure as well as the capacitors voltage balancing methods are the main novelties of the paper.
Also, the capacitors values are considered to be different (which is unavoidable in practice) while their voltages are balanced using the proposed voltage balancing methods.
In this paper, a CS-DSTATCOM has been designed for 11 kV distribution grid and several simulation results are provided in the MATLAB/Simulink environment which validate the feasibility and performance of the proposed CS-DSTATCOM.

Related Results

KONTESTASI TASAWUF SUNNÎ DAN TASAWUF FALSAFÎ DI NUSANTARA
KONTESTASI TASAWUF SUNNÎ DAN TASAWUF FALSAFÎ DI NUSANTARA
<p>This article scrutinizes the history of Islamic development in Nusantara between 15th to 18th centuries, which has been colored from theological mysticism thought. Uniquel...
CONJUNTURA
CONJUNTURA
<!--[if gte mso 9]><xml> <o:DocumentProperties> <o:Revision>0</o:Revision> <o:TotalTime>0</o:TotalTime> <o:Pages>1</o:Pages> &...
Modelling and fault ride-through control of grid supporting inverter-based microgrid
Modelling and fault ride-through control of grid supporting inverter-based microgrid
This thesis is focused on modeling and fault ride-through control, local load power delivery, and grid power exchange of power electronic interfaced Distributed Energy Resources (D...
Performance Evaluation of DSTATCOM for 180 km 33 kV Feeder from Shinyanga to Bariadi in Tanzania
Performance Evaluation of DSTATCOM for 180 km 33 kV Feeder from Shinyanga to Bariadi in Tanzania
This article presents the performance evaluation of distribution static compensators (DSTATCOM) for the 180 km 33 kV line from Shinyanga to Bariadi in Tanzania. First, the voltage ...
Real-time mode of operation data analysis to catch the thread-tip denotes the failure cause of the grid-tie PV central inverter
Real-time mode of operation data analysis to catch the thread-tip denotes the failure cause of the grid-tie PV central inverter
AbstractThe inverter is considered the core of the PV power plant. The inverter’s failure leads to generation loss and decreases plant availability. So, it is required to investiga...

Back to Top