Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Evaluation of biocompatibility of Commercial Pure Titanium / Bioactive Glass Ceramic Functionally Graded Material as Dental Implant Material In-Vivo study

View through CrossRef
Background: the ultimate goal of modern implantology is fine and fast osseointegration which is a major factor influencing the success of dental implantation, and the optimum circumstances of it the biointegration which is the occurrence of continuity of ceramic implant to bone without intervening space.   Material and method: Two groups of cylindrical implant specimens were prepared from functionally graded material and commercial pure titanium. Each group composed of 40 implant specimens.  The femur of 20 white male New Zealand rabbits, were chosen as implantation sites.  Push out test was performed to measure bone bonding strength between implant specimen and bone after 2 and 4 weeks healing periods (10 rabbits for each periods). For each time interval 20 implant specimens for each group, which implanted in rabbits. Histological study for evaluation of tissue response and histomorphometric analysis was performed for measurement of new bone area at two time intervals. Result: the results of push out force and new bone formation area appeared that mean values of functionally graded material implant specimens were a statistically highly significant more than that of commercial pure titanium implant specimens after 2 weeks and 4 weeks of implantation. In histological examination, there was an active osteoid tissue around functionally graded material implants and hematopoietic tissues around commercial pure titanium implants after 2 weeks, and there was an osteoid maturation with observation of reversal lines around functionally graded material implants and new bone formation with osteocyte around commercial pure titanium implants after 4 weeks of implantation.
Al-Mustansiriyah University - College of Dentistry
Title: Evaluation of biocompatibility of Commercial Pure Titanium / Bioactive Glass Ceramic Functionally Graded Material as Dental Implant Material In-Vivo study
Description:
Background: the ultimate goal of modern implantology is fine and fast osseointegration which is a major factor influencing the success of dental implantation, and the optimum circumstances of it the biointegration which is the occurrence of continuity of ceramic implant to bone without intervening space.
  Material and method: Two groups of cylindrical implant specimens were prepared from functionally graded material and commercial pure titanium.
Each group composed of 40 implant specimens.
  The femur of 20 white male New Zealand rabbits, were chosen as implantation sites.
  Push out test was performed to measure bone bonding strength between implant specimen and bone after 2 and 4 weeks healing periods (10 rabbits for each periods).
For each time interval 20 implant specimens for each group, which implanted in rabbits.
Histological study for evaluation of tissue response and histomorphometric analysis was performed for measurement of new bone area at two time intervals.
Result: the results of push out force and new bone formation area appeared that mean values of functionally graded material implant specimens were a statistically highly significant more than that of commercial pure titanium implant specimens after 2 weeks and 4 weeks of implantation.
In histological examination, there was an active osteoid tissue around functionally graded material implants and hematopoietic tissues around commercial pure titanium implants after 2 weeks, and there was an osteoid maturation with observation of reversal lines around functionally graded material implants and new bone formation with osteocyte around commercial pure titanium implants after 4 weeks of implantation.

Related Results

Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Root fractures are relatively uncommon compared to other types of dental traumas. It is sometimes extremely difficult for practitioners to decide what should be done and which appr...
Guest Editorial
Guest Editorial
Dental caries is one of the major health problems in Indonesia. Data from Indonesian Basic Health Research in 2013, 2015 and 2018 showed a consistent increase in the prevalence of ...
Nonlinear Vibration of a Functionally Graded Nanobeam Based on the Nonlocal Strain Gradient Theory considering Thickness Effect
Nonlinear Vibration of a Functionally Graded Nanobeam Based on the Nonlocal Strain Gradient Theory considering Thickness Effect
In this work, a nonlocal strain gradient beam model considering the thickness effect is developed to study the nonlinear vibration response of a functionally graded nanobeam. The g...
Preparation of Bioactive Hydroxyapatite on Pure Titanium
Preparation of Bioactive Hydroxyapatite on Pure Titanium
In this study, a hydroxyapatite (HA) was coated on a pure titanium surface by means of a complex oxidation and hydrothermal treatment. First an anodic oxidation was done on the tit...