Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

iCover as Bridging Stent Graft in Fenestrated Endovascular Aortic Aneurysm Repair

View through CrossRef
Background: Complex endovascular repair with fenestrated or branched stent grafts is a common approach for treating various types of aortic aneurysms. Bridging stent grafts (BSs) are crucial in connecting aortic endoprosthesis to target vessels, yet current options have demonstrated significant complications. Objective: This retrospective single-center study evaluates the initial outcomes and durability of the iCover stent graft (iCover-SG) when used as a BS in fenestrated endovascular aneurysm repair (FEVAR). Methods: Retrospective analysis screened procedures for complex aortic aneurysms between August 2021 and January 2024. Patients who underwent FEVAR with iCover-SG as BS were included. Primary and secondary endpoints focused on freedom from iCover-SG-related target vessel instability, technical success, and postoperative outcomes. Results: Within the cohort of 28 patients, 94 iCover-SGs were used as BS, supplying 87 target vessels. The freedom from iCover-SG-related target vessel instability throughout the study reached 94% (82/87). Technical success rates were notably high, with primary success achieved in 94% of cases and secondary success in 99%. Over the follow-up duration, there were instances necessitating reintervention related to iCover-SG, including 4 cases of endoleak, 2 cases of T1cEL, and 2 cases of T3cEL. In-hospital mortality was 7% (n=4), with 2 cases attributed to intraoperative complications. Importantly, no deaths were directly attributed to iCover-SG-related issues. Conclusion: The iCover-SG demonstrates promising initial outcomes as a BS in FEVAR, with high technical success rates and satisfactory rates of target vessel instability. Continued monitoring and further studies are warranted to assess long-term durability and outcomes. Clinical Impact This study shows that the iCover stent graft achieves satisfactory technical success and target vessel stability in the short- and mid-term when used as a bridging stent graft in FEVAR procedures. Its successful integration into clinical practice broadens the range of available options, providing clinicians with more versatile tools for managing complex endovascular aortic aneurysms. This expanded selection of bridging stent grafts allows for more personalised treatment strategies, improving procedural precision and patient outcomes. The iCover stent graft’s reliable performance highlights its potential as a valuable addition to current endovascular techniques, ultimately enhancing patient care in challenging cases.
Title: iCover as Bridging Stent Graft in Fenestrated Endovascular Aortic Aneurysm Repair
Description:
Background: Complex endovascular repair with fenestrated or branched stent grafts is a common approach for treating various types of aortic aneurysms.
Bridging stent grafts (BSs) are crucial in connecting aortic endoprosthesis to target vessels, yet current options have demonstrated significant complications.
Objective: This retrospective single-center study evaluates the initial outcomes and durability of the iCover stent graft (iCover-SG) when used as a BS in fenestrated endovascular aneurysm repair (FEVAR).
Methods: Retrospective analysis screened procedures for complex aortic aneurysms between August 2021 and January 2024.
Patients who underwent FEVAR with iCover-SG as BS were included.
Primary and secondary endpoints focused on freedom from iCover-SG-related target vessel instability, technical success, and postoperative outcomes.
Results: Within the cohort of 28 patients, 94 iCover-SGs were used as BS, supplying 87 target vessels.
The freedom from iCover-SG-related target vessel instability throughout the study reached 94% (82/87).
Technical success rates were notably high, with primary success achieved in 94% of cases and secondary success in 99%.
Over the follow-up duration, there were instances necessitating reintervention related to iCover-SG, including 4 cases of endoleak, 2 cases of T1cEL, and 2 cases of T3cEL.
In-hospital mortality was 7% (n=4), with 2 cases attributed to intraoperative complications.
Importantly, no deaths were directly attributed to iCover-SG-related issues.
Conclusion: The iCover-SG demonstrates promising initial outcomes as a BS in FEVAR, with high technical success rates and satisfactory rates of target vessel instability.
Continued monitoring and further studies are warranted to assess long-term durability and outcomes.
Clinical Impact This study shows that the iCover stent graft achieves satisfactory technical success and target vessel stability in the short- and mid-term when used as a bridging stent graft in FEVAR procedures.
Its successful integration into clinical practice broadens the range of available options, providing clinicians with more versatile tools for managing complex endovascular aortic aneurysms.
This expanded selection of bridging stent grafts allows for more personalised treatment strategies, improving procedural precision and patient outcomes.
The iCover stent graft’s reliable performance highlights its potential as a valuable addition to current endovascular techniques, ultimately enhancing patient care in challenging cases.

Related Results

Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Background: This study aims to identify pararenal aortic diameter changes following endovascular aortic repair and to investigate the effects of suprarenal fixation on renal functi...
Endovascular Surgery of Descending Thoracic Aorta Involved in T4 Lung Tumor
Endovascular Surgery of Descending Thoracic Aorta Involved in T4 Lung Tumor
Purpose: Surgical treatment of primary lung T4 tumors is controversial especially when the cancer invades the mediastinal structures or the descending thoracic aorta. Conventional ...
Recent Patents of Stent Grafts for Intravascular Aortic Repair
Recent Patents of Stent Grafts for Intravascular Aortic Repair
Introduction: Endovascular aortic repair involves the placement of stents through minimally invasive methods to seal rupture sites near the aortic inflow tract, thereby preventing ...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia. ...
Diseases of the Aorta
Diseases of the Aorta
This review covers the major presentations affecting the aorta: aortic aneurysms (abdominal aortic aneurysms and thoracic aortic aneurysms), acute aortic syndromes (including aorti...

Back to Top