Clinical performance of subcutaneous vs. transvenous implantable defibrillator in patients with ischemic cardiomyopathy: data from Monaldi Rhythm Registry

View through CrossRef
IntroductionSubcutaneous ICD (S-ICD) is an alternative to a transvenous implantable cardioverter-defibrillator (TV-ICD) system in selected patients not in need of pacing or resynchronization. Currently, little is known about the effectiveness and safety of S-ICD in patients with ischemic cardiomyopathy (ICM). The aim of our study was to describe the clinical features and the drivers of S-ICD implantation among patients with ICM, as well as the clinical performance of S-ICD vs. TV-ICD among this subset of patients during a long-term follow-up.Materials and methodsAll ICM patients with both S-ICD and TV-ICD implanted and followed at Monaldi Hospital from January 1, 2015, to January 1, 2024, were evaluated; among them, only ICD recipients with no pacing indication were included. We collected clinical and anamnestic characteristics, as well as ICD inappropriate therapies, ICD-related complications and infections.ResultsA total of 243 ICM patients (mean age 63.0 ± 11.0, male 86.0%) implanted with TV-ICD (n: 129, 53.1%) and S-ICD (n: 114, 46.9%) followed at our center for a median follow-up of 66.9 [39.4–96.4] months were included in the study. Kaplan–Meier analysis revealed no significant difference in the risk of inappropriate ICD therapies (log-rank p = 0.137) or ICD-related complications (log-rank p = 0.055) between S-ICD and TV-ICD groups. TV-ICD patients showed a significantly higher risk of ICD-related infections compared to those in the S-ICD group (log-rank p = 0.048). At multivariate logistic regression analysis, the only independent predictors of S-ICD implantation were female sex [OR: 52.62; p < 0.001] and primary prevention [OR: 17.60; p < 0.001].ConclusionsAmong patients with ICM not in need of pacing or resynchronization (CRT), the decision to implant an S-ICD was primarily influenced by female gender and primary prevention indications. No significant differences in inappropriate ICD therapies and complications were found; in contrast, the S-ICD group showed a numerically reduced risk of ICD-related infections.
Title: Clinical performance of subcutaneous vs. transvenous implantable defibrillator in patients with ischemic cardiomyopathy: data from Monaldi Rhythm Registry
Description:
IntroductionSubcutaneous ICD (S-ICD) is an alternative to a transvenous implantable cardioverter-defibrillator (TV-ICD) system in selected patients not in need of pacing or resynchronization.
Currently, little is known about the effectiveness and safety of S-ICD in patients with ischemic cardiomyopathy (ICM).
The aim of our study was to describe the clinical features and the drivers of S-ICD implantation among patients with ICM, as well as the clinical performance of S-ICD vs.
TV-ICD among this subset of patients during a long-term follow-up.
Materials and methodsAll ICM patients with both S-ICD and TV-ICD implanted and followed at Monaldi Hospital from January 1, 2015, to January 1, 2024, were evaluated; among them, only ICD recipients with no pacing indication were included.
We collected clinical and anamnestic characteristics, as well as ICD inappropriate therapies, ICD-related complications and infections.
ResultsA total of 243 ICM patients (mean age 63.
0 ± 11.
0, male 86.
0%) implanted with TV-ICD (n: 129, 53.
1%) and S-ICD (n: 114, 46.
9%) followed at our center for a median follow-up of 66.
9 [39.
4–96.
4] months were included in the study.
Kaplan–Meier analysis revealed no significant difference in the risk of inappropriate ICD therapies (log-rank p = 0.
137) or ICD-related complications (log-rank p = 0.
055) between S-ICD and TV-ICD groups.
TV-ICD patients showed a significantly higher risk of ICD-related infections compared to those in the S-ICD group (log-rank p = 0.
048).
At multivariate logistic regression analysis, the only independent predictors of S-ICD implantation were female sex [OR: 52.
62; p < 0.
001] and primary prevention [OR: 17.
60; p < 0.
001].
ConclusionsAmong patients with ICM not in need of pacing or resynchronization (CRT), the decision to implant an S-ICD was primarily influenced by female gender and primary prevention indications.
No significant differences in inappropriate ICD therapies and complications were found; in contrast, the S-ICD group showed a numerically reduced risk of ICD-related infections.

Related Results

Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Abstract 9276: Subcutaneous and Transvenous Defibrillator in Arrhythmogenic Right Ventricular Cardiomyopathy
Abstract 9276: Subcutaneous and Transvenous Defibrillator in Arrhythmogenic Right Ventricular Cardiomyopathy
Introduction: There is limited evidence guiding the selection between subcutaneous and transvenous ICD in patients with arrhythmogenic right ventricular cardiomyopathy ...
The effects of age on quality of life in implantable cardioverter defibrillator recipients
The effects of age on quality of life in implantable cardioverter defibrillator recipients
Background.  The implantable cardioverter defibrillator shows superiority over conventional pharmacological therapy. The implantable cardioverter defibrillator has been implanted w...
A Case of Takotsubo Cardiomyopathy Following Postpartum Hemorrhage in a Patient with Concurrent Influenza A
A Case of Takotsubo Cardiomyopathy Following Postpartum Hemorrhage in a Patient with Concurrent Influenza A
Background Takotsubo cardiomyopathy, also known as stress cardiomyopathy and broken heart syndrome, is a transient, non-ischemic cardiomyopathy marked by revers...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract Introduction Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Peri-Infarct Quantification by Cardiac Magnetic Resonance to Predict Outcomes in Ischemic Cardiomyopathy
Peri-Infarct Quantification by Cardiac Magnetic Resonance to Predict Outcomes in Ischemic Cardiomyopathy
Background: In ischemic cardiomyopathy, cardiac magnetic resonance assessment of the peri-infarct zone, a potential substrate for arrhythmogenesis, may serve as a novel...

Back to Top