Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Influence of displacement ventilation on the distribution of pollutant concentrations in livestock housing

View through CrossRef
Abstract Under replacement ventilation conditions, a simplified physical model of a tall space (livestock house) was established using ProSim software, and the relevant boundary conditions were set. The airflow size and direction distribution under different air supply and exhaust airflow conditions were obtained by slicing, and the simulation results showed that appropriately increasing the air supply and exhaust airflow helps to increase the pollutant emission rate so that pollutants can be discharged in time, but when the air supply and exhaust airflow were increased to a certain extent, these will cause the airflow vortex phenomenon near the pollutant source, which will enhance the mixing effect of pollutants and surrounding air, making up the pollutant concentration also. The study found that when the indoor air supply and exhaust air volume is increased by 45 times/h, the replacement ventilation effect is optimal and the indoor pollutant concentration is the lowest.
Title: Influence of displacement ventilation on the distribution of pollutant concentrations in livestock housing
Description:
Abstract Under replacement ventilation conditions, a simplified physical model of a tall space (livestock house) was established using ProSim software, and the relevant boundary conditions were set.
The airflow size and direction distribution under different air supply and exhaust airflow conditions were obtained by slicing, and the simulation results showed that appropriately increasing the air supply and exhaust airflow helps to increase the pollutant emission rate so that pollutants can be discharged in time, but when the air supply and exhaust airflow were increased to a certain extent, these will cause the airflow vortex phenomenon near the pollutant source, which will enhance the mixing effect of pollutants and surrounding air, making up the pollutant concentration also.
The study found that when the indoor air supply and exhaust air volume is increased by 45 times/h, the replacement ventilation effect is optimal and the indoor pollutant concentration is the lowest.

Related Results

An analysis on housing affordability in Malaysian housing markets and the home buyers’ preference
An analysis on housing affordability in Malaysian housing markets and the home buyers’ preference
Purpose This paper aims to investigate the housing preference and housing affordability in Malaysian housing markets. There is a lack of research on the gap betwe...
Housing Discourse: Historical development, epistemological gap and sociological modeling
Housing Discourse: Historical development, epistemological gap and sociological modeling
<p>Housing issue is essentially major social issue. Even though housing is vital for individual life and social life, the attention given to its theorization and epistemologi...
Housing Discourse: Historical development, epistemological gap and sociological modeling
Housing Discourse: Historical development, epistemological gap and sociological modeling
<p>Housing issue is essentially major social issue. Even though housing is vital for individual life and social life, the attention given to its theorization and epistemologi...
Espais comuns als edificis col·lectius d’habitatge social
Espais comuns als edificis col·lectius d’habitatge social
Purpose of the research: The research aims to explore the chances of improving environmental conditions for users of collective housing buildings by developing common areas as plac...
Problems and Improvements to Special Supply System of Housing
Problems and Improvements to Special Supply System of Housing
In order to solve the housing problem, Korea enacted a related legal system and implemented a system for the purpose of quantitative supply of housing. However, according to the se...
SOCIAL HOUSING IN UKRAINE: CHALLENGES AND PROSPECTS
SOCIAL HOUSING IN UKRAINE: CHALLENGES AND PROSPECTS
Background. The concept of social housing is a recent one, but as an idea, it dates back to the First Industrial Revolution. The modern definition of social housing, while varying ...
Ventilation in university classrooms during the COVID-19 pandemic
Ventilation in university classrooms during the COVID-19 pandemic
The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) virus has caused a pandemic, forcing schools and universities to stop in-person classes. For universities to allow ...
Challenges facing housing affordability in Beijing in the twenty‐first century
Challenges facing housing affordability in Beijing in the twenty‐first century
PurposeThe purpose of this paper is analyse to what extent the high price had led to low levels of housing affordability in the period 2002‐2006 in Beijing. Due to the importance o...

Back to Top