In vitro comparative study of the surface properties of materials for removable prosthetic bases

View through CrossRef
Objectives: This work aimed to evaluate and compare the surface roughness, contact angle, and C. albicans adhesion in three materials for removable denture bases: polymethylmethacrylate and the thermoplastic resins polypropylene and polyolefin. Methods: Nine samples were manufactured, three of each material (n=3): polypropylene, polyolefin, and polymethylmethacrylate (control group). The thermoplastic resins were fabricated by injection technique and the polymethylmethacrylate by compression technique. After laboratory polishing, the surface roughness (Ra and Rz) was assessed with the 3D optical roughness meter NPFLEX, and the contact angle was measured with the optical tensiometer Contact angle system OCA15. C. albicans adhesion was assessed through colony- forming unit assays (n=9). ANOVA and Kruskal-Wallis tests were done to compare groups, considering a significance level of 0.05. Results: All values obtained for the control group were lower than those obtained for the thermoplastic resins. Statistically significant differences were found: for Ra between polypropylene (0.15±0.072 μm) and polymethylmethacrylate (0.03±0.006 μm) (p=0.045); for the contact angle between the three groups (p<0.001) – polymethylmethacrylate (26.57±6.719°), polypropylene (57.57±11.098°), and polyolefin (69.06±8.955°); and for C. albicans adhesion between polymethylmethacrylate and polypropylene (p=0.007) and polymethylmethacrylate and polyolefin (p=0.013). Conclusions: In the tested conditions and for the materials assessed, polymethylmethacrylate showed the lowest roughness, contact angle, and C. albicans adhesion, thus exhibiting better properties for removable denture bases than the thermoplastic materials.
Title: In vitro comparative study of the surface properties of materials for removable prosthetic bases
Description:
Objectives: This work aimed to evaluate and compare the surface roughness, contact angle, and C.
albicans adhesion in three materials for removable denture bases: polymethylmethacrylate and the thermoplastic resins polypropylene and polyolefin.
Methods: Nine samples were manufactured, three of each material (n=3): polypropylene, polyolefin, and polymethylmethacrylate (control group).
The thermoplastic resins were fabricated by injection technique and the polymethylmethacrylate by compression technique.
After laboratory polishing, the surface roughness (Ra and Rz) was assessed with the 3D optical roughness meter NPFLEX, and the contact angle was measured with the optical tensiometer Contact angle system OCA15.
C.
albicans adhesion was assessed through colony- forming unit assays (n=9).
ANOVA and Kruskal-Wallis tests were done to compare groups, considering a significance level of 0.
05.
Results: All values obtained for the control group were lower than those obtained for the thermoplastic resins.
Statistically significant differences were found: for Ra between polypropylene (0.
15±0.
072 μm) and polymethylmethacrylate (0.
03±0.
006 μm) (p=0.
045); for the contact angle between the three groups (p<0.
001) – polymethylmethacrylate (26.
57±6.
719°), polypropylene (57.
57±11.
098°), and polyolefin (69.
06±8.
955°); and for C.
albicans adhesion between polymethylmethacrylate and polypropylene (p=0.
007) and polymethylmethacrylate and polyolefin (p=0.
013).
Conclusions: In the tested conditions and for the materials assessed, polymethylmethacrylate showed the lowest roughness, contact angle, and C.
albicans adhesion, thus exhibiting better properties for removable denture bases than the thermoplastic materials.

Related Results

Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Current Awareness of Removable Prosthodontics in Dentists at King Abdulaziz University
Current Awareness of Removable Prosthodontics in Dentists at King Abdulaziz University
Background: Removable prosthodontics is a branch of prosthodontics that requires a high level of knowledge and great skills. This include the basic and advanced understanding of va...
Morphologic alterations in the mucosa of the denture site in patients with full removable dentures from acrylic plastics
Morphologic alterations in the mucosa of the denture site in patients with full removable dentures from acrylic plastics
Relevance. Currently, many new agents have appeared on the market for users of removable dentures to improve adhesion, i.e. fixation and stabilization of dentures. It is important ...
Study on friction behavior at the interface between prosthetic socket and liner
Study on friction behavior at the interface between prosthetic socket and liner
Purpose: The friction characteristics at the interface between prosthetic socket and liner have an important influence on the walking function and wearing comfort of amputees. The ...
Treatment of partial mandibular edentious patients using a partially removable prostheses with extracoronal attachments
Treatment of partial mandibular edentious patients using a partially removable prostheses with extracoronal attachments
The management of uni- or bi-terminal edentulous cases in patients who cannot undergo implant-prosthetic treatment is complex and challenging, often requiring a multidisciplinary a...
Selection of Treatment Method for Repeated Removable Denture Prosthetics
Selection of Treatment Method for Repeated Removable Denture Prosthetics
Abstract. The majority of patients do not adhere to the recommended use periods for removable prosthetic appliances and seek repeated prosthetic treatment only when the condition o...
Pendampingan dan Evaluasi Produk Kaki Prostetik bagi Kelainan Kongenital Kaki di Atas Lutut (Above Knee Prosthesis)
Pendampingan dan Evaluasi Produk Kaki Prostetik bagi Kelainan Kongenital Kaki di Atas Lutut (Above Knee Prosthesis)
A prosthetic leg is a lower extremity movement aid in assisting the mobility of persons with physical disabilities. A prosthetic leg is used to replace a missing leg, either due to...

Back to Top