Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Transient Hepatic Elastography in the Assessment of Liver Fibrosis in Patients After Liver Transplantation

View through CrossRef
Introduction and Objectives. Liver biopsy is the gold standard for assessing fibrosis and inflammation in liver transplant recipients. As this study has risks, the use of noninvasive tools has been proposed, including transient elastography, a method that needs further study in this population, which is the purpose of this research. Material and methods. Demographic and clinical data were collected retrospectively in patients who received a liver transplant, underwent liver biopsy and transient elastography less than 1 year apart. Sensitivity, specificity, diagnostic accuracy and Kappa concordance test between the two methods were determined. Results. Of 356 patients evaluated after transplantation, 45 underwent liver biopsy and transient elastography within 1 year; 60.0% were male and 75.6% had hepatitis C virus infection. At the time of transient elastography, laboratory values were: mean total bilirubin 1.5 mg/dL, alanine aminotransferase 108.1 U/L, aspartate aminotransferase, 101.6 U/L, alkaline phosphatase, 96.0 U/L and gamma-glutamyl transferase 9.0 U/L. The main indications for liver biopsy were assessment for rejection, hepatitis C virus infection or both. According to liver biopsy, 82.2% presented absent or minimal fibrosis and 75.6% had no inflammation. Acute cellular rejection was present in 20.0% of cases. A cut-off point of > 9.5 kPa was used to define advanced fibrosis, while a value < 7.5 kPa was set to indicate absent or mild fibrosis. Poor agreement was found between transient elastography and liver biopsy for these categories (Kappa 0.125, sensitivity 69.5%, specificity 66.7%) and for specific stages of fibrosis (Kappa 0.095). Conclusions. Accuracy, sensitivity and specificity were low for fibrosis staging when comparing transient elastography with liver biopsy. In liver transplant recipients, transient elastography would overestimate fibrosis, probably due to inflammation secondary to other causes.
Title: Transient Hepatic Elastography in the Assessment of Liver Fibrosis in Patients After Liver Transplantation
Description:
Introduction and Objectives.
Liver biopsy is the gold standard for assessing fibrosis and inflammation in liver transplant recipients.
As this study has risks, the use of noninvasive tools has been proposed, including transient elastography, a method that needs further study in this population, which is the purpose of this research.
Material and methods.
Demographic and clinical data were collected retrospectively in patients who received a liver transplant, underwent liver biopsy and transient elastography less than 1 year apart.
Sensitivity, specificity, diagnostic accuracy and Kappa concordance test between the two methods were determined.
Results.
Of 356 patients evaluated after transplantation, 45 underwent liver biopsy and transient elastography within 1 year; 60.
0% were male and 75.
6% had hepatitis C virus infection.
At the time of transient elastography, laboratory values were: mean total bilirubin 1.
5 mg/dL, alanine aminotransferase 108.
1 U/L, aspartate aminotransferase, 101.
6 U/L, alkaline phosphatase, 96.
0 U/L and gamma-glutamyl transferase 9.
0 U/L.
The main indications for liver biopsy were assessment for rejection, hepatitis C virus infection or both.
According to liver biopsy, 82.
2% presented absent or minimal fibrosis and 75.
6% had no inflammation.
Acute cellular rejection was present in 20.
0% of cases.
A cut-off point of > 9.
5 kPa was used to define advanced fibrosis, while a value < 7.
5 kPa was set to indicate absent or mild fibrosis.
Poor agreement was found between transient elastography and liver biopsy for these categories (Kappa 0.
125, sensitivity 69.
5%, specificity 66.
7%) and for specific stages of fibrosis (Kappa 0.
095).
Conclusions.
Accuracy, sensitivity and specificity were low for fibrosis staging when comparing transient elastography with liver biopsy.
In liver transplant recipients, transient elastography would overestimate fibrosis, probably due to inflammation secondary to other causes.

Related Results

Physical Principles of Elastography: A Primer for Radiologists
Physical Principles of Elastography: A Primer for Radiologists
AbstractElastography is the noninvasive method of qualitative and quantitative evaluation of strain and elastic modulus distribution in soft tissues. In simpler terms, elastography...
[RETRACTED] Bridport Health Reviews - Powerfully Detoxifies The Liver, Lose Liver Fat And Improve Gut Health! v1
[RETRACTED] Bridport Health Reviews - Powerfully Detoxifies The Liver, Lose Liver Fat And Improve Gut Health! v1
[RETRACTED]Product Name - Bridport Health Ingredients - Milk Thistle, Beetroot, Artichoke Extract & More. Category - Liver Support Supplement Main Benefits - Helps Protect The ...
[RETRACTED] Bridport Health Liver Support Does It Really Work v1
[RETRACTED] Bridport Health Liver Support Does It Really Work v1
[RETRACTED]Depiction • Where to Get Bottle Online –Click Here • Item Name -Bridport Health Liver • Aftereffects - No Major Side Effects • Classification - Health • Accessibility -O...
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
Background: Liver fibrosis staging plays a key role in the prognosis and management of chronic liver disease. Liver biopsy remains the reference standard for fibrosis assessment bu...
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
Liver fibrosis staging plays a key role in the prognosis and management of chronic liver disease. Liver biopsy remains the reference standard for fibrosis assessment but is limited...

Back to Top