Javascript must be enabled to continue!
A Detailed Experimental Study on The Flexural Behaviour of Concrete Filled Steel Tube Beams
View through CrossRef
Concrete filled steel tubes (CFST) member have many advantages compared with the ordinary structural member made of steel or reinforced concrete. One of the main advantages is the interaction between the steel tube and concrete. Concrete delays the steel tube’s local buckling, whereas the steel tube confines the concrete and thereby increases the concrete’s strength. CFSTs are economical and permit rapid construction because the steel tube serves as formwork and reinforcement to the concrete fill, negating the need for either. The deformation capacity of the system is increased by the combined action of the concrete fill with the thin, ductile steel tube. The concrete fill significantly increases inelastic deformation capacity and the compressive stiffness and load capacity of the CFST member. In building construction concrete filled steel tubes are very widely used for columns in combination with steel or reinforced concrete beam. In this work totally 9 specimens were tested out of which 3 specimens were empty steel tubes and remaining 6 specimens were concrete filled with different bonding techniques. As it is prefabricated time consumption will be less in construction practice and due to confinement more ductility is expected which is very useful in earthquake resistant structures. Load carrying capacity of CFST almost doubled in comparison with empty steel tubes. Ultimate load carrying capacity of concrete filled steel tube beams almost doubled compared to empty steel tubes. Compared to empty steel tubes, strength increase of 67.19%, 97.48% and 114.84% was observed in normal CFST, CFST with sand blasting and CFST with diagonal shear connector beams respectively. Average ultimate load of EST was 105.66kN whereas average load of CFSTB, CFSTBWSB and CFSTBWDSC was 176.66, 208.66 and 227kN respectively. The maximum load was taken by the specimen CFSTBWDSC – 03 which was 231kN, it may be because of presence of diagonal shear connector inside the tube.
Title: A Detailed Experimental Study on The Flexural Behaviour of Concrete Filled Steel Tube Beams
Description:
Concrete filled steel tubes (CFST) member have many advantages compared with the ordinary structural member made of steel or reinforced concrete.
One of the main advantages is the interaction between the steel tube and concrete.
Concrete delays the steel tube’s local buckling, whereas the steel tube confines the concrete and thereby increases the concrete’s strength.
CFSTs are economical and permit rapid construction because the steel tube serves as formwork and reinforcement to the concrete fill, negating the need for either.
The deformation capacity of the system is increased by the combined action of the concrete fill with the thin, ductile steel tube.
The concrete fill significantly increases inelastic deformation capacity and the compressive stiffness and load capacity of the CFST member.
In building construction concrete filled steel tubes are very widely used for columns in combination with steel or reinforced concrete beam.
In this work totally 9 specimens were tested out of which 3 specimens were empty steel tubes and remaining 6 specimens were concrete filled with different bonding techniques.
As it is prefabricated time consumption will be less in construction practice and due to confinement more ductility is expected which is very useful in earthquake resistant structures.
Load carrying capacity of CFST almost doubled in comparison with empty steel tubes.
Ultimate load carrying capacity of concrete filled steel tube beams almost doubled compared to empty steel tubes.
Compared to empty steel tubes, strength increase of 67.
19%, 97.
48% and 114.
84% was observed in normal CFST, CFST with sand blasting and CFST with diagonal shear connector beams respectively.
Average ultimate load of EST was 105.
66kN whereas average load of CFSTB, CFSTBWSB and CFSTBWDSC was 176.
66, 208.
66 and 227kN respectively.
The maximum load was taken by the specimen CFSTBWDSC – 03 which was 231kN, it may be because of presence of diagonal shear connector inside the tube.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Dynamic Characteristics Analysis of Three-Layer Steel–Concrete Composite Beams
Dynamic Characteristics Analysis of Three-Layer Steel–Concrete Composite Beams
The dynamic behavior of three-layer composite beams, consisting of concrete slabs and steel beams, is influenced by the structural configuration of each layer as well as the shear ...
Aportaciones al estudio del comportamiento a flexión de estructuras de acero inoxidable
Aportaciones al estudio del comportamiento a flexión de estructuras de acero inoxidable
L'acer inoxidable està essent utilitzat de manera creixent en els últims anys als sectors de la indústria i de l'arquitectura gràcies a la seva resistència a la corrosió, facilitat...
Experimental study and computational analysis of structural performance of reinforced geopolymer concrete beams
Experimental study and computational analysis of structural performance of reinforced geopolymer concrete beams
PurposeIn this study, the aim is to explore the effects of geopolymer concrete (GPC) strength and reinforcement ratio on the flexural performance of reinforced GPC beams. Furthermo...
Strengthening and Characterization of Existing Reinforced Concrete Beams for Flexure by Effective Utilization of External Steel Elements
Strengthening and Characterization of Existing Reinforced Concrete Beams for Flexure by Effective Utilization of External Steel Elements
Strengthening of structural members is a common practice around the world that may arise due to deterioration of concrete with age or upgradation of design code. This paper aims to...
Shear Stresses of Hollow Lightweight Concrete Beams Made with Wood Waste
Shear Stresses of Hollow Lightweight Concrete Beams Made with Wood Waste
Hollow Lightweight Concrete (HLC) beams are gaining popularity due to low cost and low weight as compared with the Solid Lightweight Concrete (SLC) beams. HLC and SLC beams decreas...
Effect of steel fiber on the shear behavior of reinforced recycled aggregate concrete beams
Effect of steel fiber on the shear behavior of reinforced recycled aggregate concrete beams
AbstractIn this research, the influence of using steel fibers on the shear action of reinforced concrete beams, made of recycled concrete aggregate (RCA), was investigated through ...
Experimental investigation of concrete-filled and bare 6082-T6 aluminium alloy tubes under in-plane bending
Experimental investigation of concrete-filled and bare 6082-T6 aluminium alloy tubes under in-plane bending
The application of aluminium alloys in construction sector is increasing owing to their excellent corrosion resistance, light weight and attractive appearance. However, one of the ...

