Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Fabrication and evaluation of an oxygen microelectrode applicable to environmental engineering and science

View through CrossRef
This paper introduces the fabrication procedure and evaluation method of an oxygen microelectrode applicable to environmental engineering and science research. The theory and development of an oxygen microelectrode technique are introduced. The fabrication procedure of a combined oxygen microelectrode with small-tip diameter (15–20 μμm) is described in detail. This microelectrode was then evaluated by subjecting it to a polarization voltage of –0.8 V and calibrating against known dissolved oxygen concentrations from zero to air saturation. The results of the evaluation demonstrated that the fabrication procedure reported in this paper was successful. This microelectrode had a fast response time (<2 s), stable reading with good calibration linearity (R2 = 1), low residual current signal (6 pA), and low stirring effect (4%). No electromagnetic interference was observed when this combined oxygen microelectrode was used under both laboratory and field conditions. The combined oxygen microelectrode fabricated using this procedure can be used for in situ measurement of dissolved oxygen in wastewater biofilms under field conditions. Key words: microelectrode, microsensor, oxygen, fabrication, polarization, calibration, biofilm, wastewater.
Title: Fabrication and evaluation of an oxygen microelectrode applicable to environmental engineering and science
Description:
This paper introduces the fabrication procedure and evaluation method of an oxygen microelectrode applicable to environmental engineering and science research.
The theory and development of an oxygen microelectrode technique are introduced.
The fabrication procedure of a combined oxygen microelectrode with small-tip diameter (15–20 μμm) is described in detail.
This microelectrode was then evaluated by subjecting it to a polarization voltage of –0.
8 V and calibrating against known dissolved oxygen concentrations from zero to air saturation.
The results of the evaluation demonstrated that the fabrication procedure reported in this paper was successful.
This microelectrode had a fast response time (<2 s), stable reading with good calibration linearity (R2 = 1), low residual current signal (6 pA), and low stirring effect (4%).
No electromagnetic interference was observed when this combined oxygen microelectrode was used under both laboratory and field conditions.
The combined oxygen microelectrode fabricated using this procedure can be used for in situ measurement of dissolved oxygen in wastewater biofilms under field conditions.
Key words: microelectrode, microsensor, oxygen, fabrication, polarization, calibration, biofilm, wastewater.

Related Results

High Concentration Oxygen and Hypercapnia in Respiratory Disease
High Concentration Oxygen and Hypercapnia in Respiratory Disease
<p>Oxygen-induced elevations in arterial carbon dioxide tension have been demonstrated in patients with chronic obstructive pulmonary disease (COPD), asthma, pneumonia, obesi...
Simulation on the Microelectrode of Cell Electrofusion Chip
Simulation on the Microelectrode of Cell Electrofusion Chip
The process of cell electrofusion including cell alignment, cell electroporation cell electrofusion. Cell manipulation mainly related to the electric field gradient and electropor...
Closed-Loop Oxygen Control
Closed-Loop Oxygen Control
<p>Guidelines recommend that oxygen should be titrated to achieve a target oxygen saturation (SpO2 ) range in acutely unwell patients, a concept colloquially known as “swimmi...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
A Tapered Aluminium Microelectrode Array for Improvement of Dielectrophoresis-Based Particle Manipulation
A Tapered Aluminium Microelectrode Array for Improvement of Dielectrophoresis-Based Particle Manipulation
In this work, the dielectrophoretic force (FDEP) response of Aluminium Microelectrode Arrays with tapered profile is investigated through experimental measurements and numerical si...
Nanostructured porous silicon scaffolds for enhanced biocompatibility of multichannel microelectrodes
Nanostructured porous silicon scaffolds for enhanced biocompatibility of multichannel microelectrodes
Many different types of microelectrodes have been developed for use as a direct Brain-Machine Interface (BMI) to chronically record single- neuron action potentials from ensembles ...
Clinical Audit: Oxygen Prescription with Target Saturations in Post Anesthesia Care Unit
Clinical Audit: Oxygen Prescription with Target Saturations in Post Anesthesia Care Unit
Background: Supplemental oxygen therapy is commonly administered to the majority of postoperative surgical patients in order to prevent hypoxemia, which is one of the most common a...
AI Engineering: A Strategic Research Framework to Benefit Society
AI Engineering: A Strategic Research Framework to Benefit Society
The strategic convergence of artificial intelligence (AI) and engineering, envisioned as AI Engineering, represents a generational opportunity to supercharge engineering for the be...

Back to Top