Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Stiff Guidewires in Endourology: What Is Stiffness?

View through CrossRef
Introduction: The aim of this study is to perform a literature review of stiff guidewires used in urology and to investigate if there is an official definition for stiffness (shaft rigidity) of wires. Materials and Methods: A literature search was performed for all English language articles in MEDLINE and Scopus databases, Google Scholar, and the official websites of international companies. Guidewires from different companies were included. Results: We analyzed 14 different stiff guidewires from the companies, Boston Scientific, Coloplast, Cook Medical, Olympus, Terumo, Rocamed, and Bard Urological, according to their characteristics. We found no concrete data regarding their stiffness on the official websites. In addition, there were a few published studies about the Amplatz Super Stiff guidewire (Boston Scientific), ZIPwire™ Stiff Nitinol Hydrophilic guidewire (Boston Scientific), HiWire Stiff Nitinol Core Wire Guide (Cook Medical), Amplatz Fixed Core Wire Guide (Cook Medical), and NiCore™ Nitinol Guidewire–Stiff (Bard Urological), whereas there were no available data for the majority of stiff guidewires. Conclusions: Stiff guidewires are listed in catalogs of companies without any information regarding their classification. They are only divided into stiff and standard versions without knowing the differences between them. The companies and their manufacturers should adopt a common method to calculate and define the stiffness of each guidewire.
Title: Stiff Guidewires in Endourology: What Is Stiffness?
Description:
Introduction: The aim of this study is to perform a literature review of stiff guidewires used in urology and to investigate if there is an official definition for stiffness (shaft rigidity) of wires.
Materials and Methods: A literature search was performed for all English language articles in MEDLINE and Scopus databases, Google Scholar, and the official websites of international companies.
Guidewires from different companies were included.
Results: We analyzed 14 different stiff guidewires from the companies, Boston Scientific, Coloplast, Cook Medical, Olympus, Terumo, Rocamed, and Bard Urological, according to their characteristics.
We found no concrete data regarding their stiffness on the official websites.
In addition, there were a few published studies about the Amplatz Super Stiff guidewire (Boston Scientific), ZIPwire™ Stiff Nitinol Hydrophilic guidewire (Boston Scientific), HiWire Stiff Nitinol Core Wire Guide (Cook Medical), Amplatz Fixed Core Wire Guide (Cook Medical), and NiCore™ Nitinol Guidewire–Stiff (Bard Urological), whereas there were no available data for the majority of stiff guidewires.
Conclusions: Stiff guidewires are listed in catalogs of companies without any information regarding their classification.
They are only divided into stiff and standard versions without knowing the differences between them.
The companies and their manufacturers should adopt a common method to calculate and define the stiffness of each guidewire.

Related Results

Endourology Fellowship: More Than a Stone’s Throw Away for Women
Endourology Fellowship: More Than a Stone’s Throw Away for Women
Objective: To characterize the trends in female representation in the endourology fellowship match compared with the urology residency match. ...
Quantitative parameters of the kinetics and kinematics of the iatrogenic crouch gait pattern
Quantitative parameters of the kinetics and kinematics of the iatrogenic crouch gait pattern
The pattern of pathological crouch gait in patients with spastic paralysis is characteristic of diplegic forms and in natural development manifests itself usually after the age of ...
Interview: Bhaskar Somani
Interview: Bhaskar Somani
What led you to pursue a career in surgical urology? Was there a particular person or event that inspired you? As a junior doctor in training, I enjoyed all aspects of surgery, hav...
Abstract 1099: Mapping matrix mechanics in 3D to study the role of stiffness in breast tumor progression.
Abstract 1099: Mapping matrix mechanics in 3D to study the role of stiffness in breast tumor progression.
Abstract Introduction Evidence suggests that the Extra Cellular Matrix (ECM) stiffness may be a driving factor in tumor progression and may sensitize ...
NUMERICAL DESIGN OF STEERABLE GUIDEWIRES
NUMERICAL DESIGN OF STEERABLE GUIDEWIRES
Biomedical devices are an integral part of the medical industry nowadays. With the increase in cases of heart disease, catheterization procedures are becoming more frequent. Small-...
Comparing the Safety and Effectiveness of Dedicated Radiofrequency Transseptal Wires to Electrified Metal Guidewires
Comparing the Safety and Effectiveness of Dedicated Radiofrequency Transseptal Wires to Electrified Metal Guidewires
Application of electrocautery to a metal guidewire can be used to perform transseptal puncture (TSP). Dedicated radiofrequency guidewires (RF) may represent a better alternative. T...
Stiffness regulation by reflex action in the normal human hand
Stiffness regulation by reflex action in the normal human hand
1. The torque and electromyographic (EMG) responses to stretch of the first dorsal interosseous muscle (externally imposed joint rotation) were recorded in five normal human subjec...