Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Use of laser flaremetry to measure aqueous humor protein concentration in dogs

View through CrossRef
Summary The blood-aqueous barrier in dogs is compromised by uveitis, surgery, and limbal paracentesis. Breakdown of the blood-aqueous barrier allows protein into the aqueous humor and results in mild to severe inflammation. Diagnosis of protein in the aqueous humor is traditionally a subjective measurement. Laser flaremetry was used for noninvasive quantitation of aqueous humor protein concentration in dogs. Flaremetry data were compared with aqueous humor protein concentrations obtained from aqueous humor paracentesis and slit-lamp flare evaluations. Results from clinically normal eyes and those with uveitis and cataracts were compared. Subjective evaluations of flare were correlated with a range of flaremetry readings and aqueous humor protein concentrations. Clinically normal eyes had a range of flaremetry readings of 1.4 to 7.0 photon counts (PC)/ms, with a mean of 3.8 PC/ ms. Corresponding aqueous humor protein concentrations ranged from 5 to 28 mg/dl, with a mean of 15.1 mg/dl. Eyes with uveitis or cataracts had a range of flaremetry readings of 4.9 to 245.5 PC/ms and a range of aqueous protein concentrations of 13 to 729 mg/dl. Flaremetry readings accurately and sensitively measured total protein concentrations in the aqueous humor of dogs.
Title: Use of laser flaremetry to measure aqueous humor protein concentration in dogs
Description:
Summary The blood-aqueous barrier in dogs is compromised by uveitis, surgery, and limbal paracentesis.
Breakdown of the blood-aqueous barrier allows protein into the aqueous humor and results in mild to severe inflammation.
Diagnosis of protein in the aqueous humor is traditionally a subjective measurement.
Laser flaremetry was used for noninvasive quantitation of aqueous humor protein concentration in dogs.
Flaremetry data were compared with aqueous humor protein concentrations obtained from aqueous humor paracentesis and slit-lamp flare evaluations.
Results from clinically normal eyes and those with uveitis and cataracts were compared.
Subjective evaluations of flare were correlated with a range of flaremetry readings and aqueous humor protein concentrations.
Clinically normal eyes had a range of flaremetry readings of 1.
4 to 7.
0 photon counts (PC)/ms, with a mean of 3.
8 PC/ ms.
Corresponding aqueous humor protein concentrations ranged from 5 to 28 mg/dl, with a mean of 15.
1 mg/dl.
Eyes with uveitis or cataracts had a range of flaremetry readings of 4.
9 to 245.
5 PC/ms and a range of aqueous protein concentrations of 13 to 729 mg/dl.
Flaremetry readings accurately and sensitively measured total protein concentrations in the aqueous humor of dogs.

Related Results

Jewish Humor
Jewish Humor
Jewish humor is a vast field of Jewish studies that includes many aspects, including different periods, different types, different contents, and a variety of languages in different...
Effects of Affiliative and Aggressive Humor On Creative Thinking
Effects of Affiliative and Aggressive Humor On Creative Thinking
Previous correlational studies suggest that negative humor style such as aggressive humor style is negatively and positive humor style such as affiliative humor style is positively...
REPRESENTASI BAHASA HUMOR DALAM ACARA LAPOR PAK! TRANS7
REPRESENTASI BAHASA HUMOR DALAM ACARA LAPOR PAK! TRANS7
ABSTRAK Penelitian ini bertujuan untuk mendeskripsikan bentuk dan fungsi bahasa humor dalam acara Lapor Pak!  Trans7. Jenis penelitian yang digunakan dalam penelitian ini adalah pe...
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
In order to increase the accuracy of precise orbit determination for a single satellite or satellites in LEO formation, we propose using a LEO-to-GNSS laser interferometer, what we...
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Abstract Laser light has a number of spectacular properties that make it useful for analytical spectrometry. One is that it has a high directionality (i.e. i...
Vascular endothelial growth factor in diabetic and nondiabetic canine cataract patients
Vascular endothelial growth factor in diabetic and nondiabetic canine cataract patients
AbstractObjective To measure vascular endothelial growth factor (VEGF) levels in aqueous humor, serum, and plasma in diabetic and nondiabetic cataractous dogs.Methods Canine VEGF w...
Humor in public health messaging
Humor in public health messaging
<p>While humor has been extensively studied in commercial marketing, there is less known about how humor functions in the context of a public health campaign. This dissertati...
Humor convergence based on humor type: a quantitative study of L2 humor responses
Humor convergence based on humor type: a quantitative study of L2 humor responses
Abstract Humor convergence, or responding to humor by adding a similar jocular response, is presumed to lead to positive affect and affiliation among interlocutors. ...

Back to Top