Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Development And Validation Of N-Nitroso Atomoxetine Impurity (Ndsri) Determination Method In Atomoxetine Hydrochloride With Uflc-Ms/Ms (Esi).

View through CrossRef
Now a day’s nitrosamine impurities major concern for the pharmaceutical industries due to the cancer-causing potential, they can impact on health risk, recall the products and withdrawals, process modification, financial and operational impact. Multiple regulatory authority requirements for Pharmaceuticals for Human Use has established guidelines for nitrosamine impurities, which classify them as a cohort of concern (CoC) and present potential genotoxic risks. Therefore, controlling these impurities at lower levels during the quantification process in active pharmaceutical ingredients (API) and products is crucial to ensure safe human consumption. This research paper presented a simple, fast, and trace-level quantification by LC-ESI-MS-MS analytical method for N-Nitroso atomoxetine (NDSRI) in atomoxetine hydrochloride with a LOQ of 0.02 ppm and LOD 0.006 ppm. Chromatographic separation is achieved using HPLC column Kromasil 100-5C8 (250 mm x 4.6 mm x 5µ) and mobile phase A 1mL formic acid in water and mobile phase B acetonitrile. Gradient mode with 0.8 ml/min using a total run time of 23 min. Multiple reaction monitoring (MRM) with Electron Spray Ionization (ESI) is used to identification and quantify NDSRI in a positive mode and validate regulatory guidelines. MS diverter valve to avoid MS contamination from API. Validated method is specific, linear in the range of 0.02 ppm – 0.27 ppm with regression coefficient >0.99, Accurate & Precise. A triplicate sample preparation is used to establish method recoveries, which are found to be satisfactory within the range of 70% to 130%. The N-Nitroso atomoxetine impurity in atomoxetine hydrochloride can be regularly detected using this method
Title: Development And Validation Of N-Nitroso Atomoxetine Impurity (Ndsri) Determination Method In Atomoxetine Hydrochloride With Uflc-Ms/Ms (Esi).
Description:
Now a day’s nitrosamine impurities major concern for the pharmaceutical industries due to the cancer-causing potential, they can impact on health risk, recall the products and withdrawals, process modification, financial and operational impact.
Multiple regulatory authority requirements for Pharmaceuticals for Human Use has established guidelines for nitrosamine impurities, which classify them as a cohort of concern (CoC) and present potential genotoxic risks.
Therefore, controlling these impurities at lower levels during the quantification process in active pharmaceutical ingredients (API) and products is crucial to ensure safe human consumption.
This research paper presented a simple, fast, and trace-level quantification by LC-ESI-MS-MS analytical method for N-Nitroso atomoxetine (NDSRI) in atomoxetine hydrochloride with a LOQ of 0.
02 ppm and LOD 0.
006 ppm.
Chromatographic separation is achieved using HPLC column Kromasil 100-5C8 (250 mm x 4.
6 mm x 5µ) and mobile phase A 1mL formic acid in water and mobile phase B acetonitrile.
Gradient mode with 0.
8 ml/min using a total run time of 23 min.
Multiple reaction monitoring (MRM) with Electron Spray Ionization (ESI) is used to identification and quantify NDSRI in a positive mode and validate regulatory guidelines.
MS diverter valve to avoid MS contamination from API.
Validated method is specific, linear in the range of 0.
02 ppm – 0.
27 ppm with regression coefficient >0.
99, Accurate & Precise.
A triplicate sample preparation is used to establish method recoveries, which are found to be satisfactory within the range of 70% to 130%.
The N-Nitroso atomoxetine impurity in atomoxetine hydrochloride can be regularly detected using this method.

Related Results

7 th International Symposium on Enabling Technologies for Life Sciences (ETP)
7 th International Symposium on Enabling Technologies for Life Sciences (ETP)
The seventh in the series of ETP Symposia (see Rapid Communications in Mass Spectrometry 2012, 26 , ...
Transition from Methylphenidate to Atomoxetine: reasons for switching and clinical outcome
Transition from Methylphenidate to Atomoxetine: reasons for switching and clinical outcome
AimsAttention Deficit Hyperactivity Disorder (ADHD) is a behavior disorder originating in childhood comprising of a constellation of features including inattention, impulsivity, an...
A digitized impurity database analysis method for determining the impurity profiles of gatifloxacin in bulk materials and injections
A digitized impurity database analysis method for determining the impurity profiles of gatifloxacin in bulk materials and injections
HPLC has become the most important analytical technique for impurity profiling in order to assure the quality of pharmaceutical products. Although HPLC is considered as a well-esta...
Atomoxetine, but not paroxetine, blocks norepinephrine reuptake in depressed patientss
Atomoxetine, but not paroxetine, blocks norepinephrine reuptake in depressed patientss
Purpose: Paroxetine is a potent serotonin (5-HT) reuptake inhibitor. However, a purported norepinephrine (NE) reuptake blockade action remains to be established. Atomoxetine is a p...
Abstract 4138514: From Treatment to Trigger: A Case of Atomoxetine-Induced Brugada Pattern
Abstract 4138514: From Treatment to Trigger: A Case of Atomoxetine-Induced Brugada Pattern
Introduction: Brugada syndrome is an inherited cardiac disorder characterized by specific ECG patterns, notably the coved-type ST-segment elevation in the right precord...
VALIDATED CHIRAL RP-UFLC METHOD FOR THE QUANTIFICATION OF CHLORTHALIDONE IN BULK AND PHARMACEUTICAL DOSAGE FORM
VALIDATED CHIRAL RP-UFLC METHOD FOR THE QUANTIFICATION OF CHLORTHALIDONE IN BULK AND PHARMACEUTICAL DOSAGE FORM
Objective: Development and validation of new, simple and reliable enantioselective reverse phase ultra-fast liquid chromatography (RP-UFLC) method for quantification of chlorthalid...

Back to Top