Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Quadrature demodulation based circuit implementation of pulse stream for ultrasonic signal FRI sparse sampling

View through CrossRef
Abstract Converting ultrasonic signal to ultrasonic pulse stream is the key step of finite rate of innovation (FRI) sparse sampling. At present, ultrasonic pulse-stream-forming techniques are mainly based on digital algorithms. No hardware circuit that can achieve it has been reported. This paper proposes a new quadrature demodulation (QD) based circuit implementation method for forming an ultrasonic pulse stream. Elaborating on FRI sparse sampling theory, the process of ultrasonic signal is explained, followed by a discussion and analysis of ultrasonic pulse-stream-forming methods. In contrast to ultrasonic signal envelope extracting techniques, a quadrature demodulation method (QDM) is proposed. Simulation experiments were performed to determine its performance at various signal-to-noise ratios (SNRs). The circuit was then designed, with mixing module, oscillator, low pass filter (LPF), and root of square sum module. Finally, application experiments were carried out on pipeline sample ultrasonic flaw testing. The experimental results indicate that the QDM can accurately convert ultrasonic signal to ultrasonic pulse stream, and reverse the original signal information, such as pulse width, amplitude, and time of arrival. This technique lays the foundation for ultrasonic signal FRI sparse sampling directly with hardware circuitry.
Title: Quadrature demodulation based circuit implementation of pulse stream for ultrasonic signal FRI sparse sampling
Description:
Abstract Converting ultrasonic signal to ultrasonic pulse stream is the key step of finite rate of innovation (FRI) sparse sampling.
At present, ultrasonic pulse-stream-forming techniques are mainly based on digital algorithms.
No hardware circuit that can achieve it has been reported.
This paper proposes a new quadrature demodulation (QD) based circuit implementation method for forming an ultrasonic pulse stream.
Elaborating on FRI sparse sampling theory, the process of ultrasonic signal is explained, followed by a discussion and analysis of ultrasonic pulse-stream-forming methods.
In contrast to ultrasonic signal envelope extracting techniques, a quadrature demodulation method (QDM) is proposed.
Simulation experiments were performed to determine its performance at various signal-to-noise ratios (SNRs).
The circuit was then designed, with mixing module, oscillator, low pass filter (LPF), and root of square sum module.
Finally, application experiments were carried out on pipeline sample ultrasonic flaw testing.
The experimental results indicate that the QDM can accurately convert ultrasonic signal to ultrasonic pulse stream, and reverse the original signal information, such as pulse width, amplitude, and time of arrival.
This technique lays the foundation for ultrasonic signal FRI sparse sampling directly with hardware circuitry.

Related Results

Method for Estimating and Compensating the Phase Imbalance of Quadrature Signal Components
Method for Estimating and Compensating the Phase Imbalance of Quadrature Signal Components
Currently, methods of direct modulation using complex signals are widely used. A complex signal consists of in-phase I (In-phase) and quadrature Q (Quadrature) components. When a s...
FRI-based sparse sampling for ultrasonic array signals based on pulse-positive sequence delay synthesis
FRI-based sparse sampling for ultrasonic array signals based on pulse-positive sequence delay synthesis
Abstract Ultrasonic transducer arrays have been widely applied to nondestructive testing due to their high testing efficiency and abundant echo information regard...
Development and validation of animal models for fracture-related infection
Development and validation of animal models for fracture-related infection
Fracture-related infections (FRIs) are a challenging complication in orthopaedics for all people and systems involved. The incidence of these infections is considerably high, parti...
High-Precision Continuous FBG Interrogator based on an AWG
High-Precision Continuous FBG Interrogator based on an AWG
Abstract Although arrayed waveguide gratings (AWGs) are widely used in fibre Bragg grating (FBG) demodulation systems, their applications in real environments have been lim...
An MLP-Based Demodulation Method for eLoran Ninth-Pulse Signals
An MLP-Based Demodulation Method for eLoran Ninth-Pulse Signals
As a crucial long-range positioning, navigation, and timing (PNT) system, eLoran will utilize the ninth pulse to broadcast differential data. However, conventional demodulation met...
Fracture-Related Infection of the Proximal Femur – Diagnostics and Treatment
Fracture-Related Infection of the Proximal Femur – Diagnostics and Treatment
Purpose With the aging population and rising life expectancy the incidence of trauma-related injuries, particularly proximal femur fractures, is expected to inc...
Lahar simulation using Laharz_py program for the Mt. Halla volcano, Jeju, Korea
Lahar simulation using Laharz_py program for the Mt. Halla volcano, Jeju, Korea
This study using Laharz_py program, was performed schematic prediction on the impact area of lahar hazards at the Mt. Halla volcano, Jeju island volcanic field, Korea. In order to ...