Deep learning based spectral extrapolation for dual‐source, dual‐energy x‐ray computed tomography
View through CrossRef
PurposeData completion is commonly employed in dual‐source, dual‐energy computed tomography (CT) when physical or hardware constraints limit the field of view (FoV) covered by one of two imaging chains. Practically, dual‐energy data completion is accomplished by estimating missing projection data based on the imaging chain with the full FoV and then by appropriately truncating the analytical reconstruction of the data with the smaller FoV. While this approach works well in many clinical applications, there are applications which would benefit from spectral contrast estimates over the larger FoV (spectral extrapolation)—e.g. model‐based iterative reconstruction, contrast‐enhanced abdominal imaging of large patients, interior tomography, and combined temporal and spectral imaging.MethodsTo document the fidelity of spectral extrapolation and to prototype a deep learning algorithm to perform it, we assembled a data set of 50 dual‐source, dual‐energy abdominal x‐ray CT scans (acquired at Duke University Medical Center with 5 Siemens Flash scanners; chain A: 50 cm FoV, 100 kV; chain B: 33 cm FoV, 140 kV + Sn; helical pitch: 0.8). Data sets were reconstructed using ReconCT (v14.1, Siemens Healthineers): 768 × 768 pixels per slice, 50 cm FoV, 0.75 mm slice thickness, “Dual‐Energy ‐ WFBP” reconstruction mode with dual‐source data completion. A hybrid architecture consisting of a learned piecewise linear transfer function (PLTF) and a convolutional neural network (CNN) was trained using 40 scans (five scans reserved for validation, five for testing). The PLTF learned to map chain A spectral contrast to chain B spectral contrast voxel‐wise, performing an image domain analog of dual‐source data completion with approximate spectral reweighting. The CNN with its U‐net structure then learned to improve the accuracy of chain B contrast estimates by copying chain A structural information, by encoding prior chain A, chain B contrast relationships, and by generalizing feature‐contrast associations. Training was supervised, using data from within the 33‐cm chain B FoV to optimize and assess network performance.ResultsExtrapolation performance on the testing data confirmed our network's robustness and ability to generalize to unseen data from different patients, yielding maximum extrapolation errors of 26 HU following the PLTF and 7.5 HU following the CNN (averaged per target organ). Degradation of network performance when applied to a geometrically simple phantom confirmed our method's reliance on feature‐contrast relationships in correctly inferring spectral contrast. Integrating our image domain spectral extrapolation network into a standard dual‐source, dual‐energy processing pipeline for Siemens Flash scanner data yielded spectral CT data with adequate fidelity for the generation of both 50 keV monochromatic images and material decomposition images over a 30‐cm FoV for chain B when only 20 cm of chain B data were available for spectral extrapolation.ConclusionsEven with a moderate amount of training data, deep learning methods are capable of robustly inferring spectral contrast from feature‐contrast relationships in spectral CT data, leading to spectral extrapolation performance well beyond what may be expected at face value. Future work reconciling spectral extrapolation results with original projection data is expected to further improve results in outlying and pathological cases.
Title: Deep learning based spectral extrapolation for dual‐source, dual‐energy x‐ray computed tomography
Description:
PurposeData completion is commonly employed in dual‐source, dual‐energy computed tomography (CT) when physical or hardware constraints limit the field of view (FoV) covered by one of two imaging chains.
Practically, dual‐energy data completion is accomplished by estimating missing projection data based on the imaging chain with the full FoV and then by appropriately truncating the analytical reconstruction of the data with the smaller FoV.
While this approach works well in many clinical applications, there are applications which would benefit from spectral contrast estimates over the larger FoV (spectral extrapolation)—e.
g.
model‐based iterative reconstruction, contrast‐enhanced abdominal imaging of large patients, interior tomography, and combined temporal and spectral imaging.
MethodsTo document the fidelity of spectral extrapolation and to prototype a deep learning algorithm to perform it, we assembled a data set of 50 dual‐source, dual‐energy abdominal x‐ray CT scans (acquired at Duke University Medical Center with 5 Siemens Flash scanners; chain A: 50 cm FoV, 100 kV; chain B: 33 cm FoV, 140 kV + Sn; helical pitch: 0.
8).
Data sets were reconstructed using ReconCT (v14.
1, Siemens Healthineers): 768 × 768 pixels per slice, 50 cm FoV, 0.
75 mm slice thickness, “Dual‐Energy ‐ WFBP” reconstruction mode with dual‐source data completion.
A hybrid architecture consisting of a learned piecewise linear transfer function (PLTF) and a convolutional neural network (CNN) was trained using 40 scans (five scans reserved for validation, five for testing).
The PLTF learned to map chain A spectral contrast to chain B spectral contrast voxel‐wise, performing an image domain analog of dual‐source data completion with approximate spectral reweighting.
The CNN with its U‐net structure then learned to improve the accuracy of chain B contrast estimates by copying chain A structural information, by encoding prior chain A, chain B contrast relationships, and by generalizing feature‐contrast associations.
Training was supervised, using data from within the 33‐cm chain B FoV to optimize and assess network performance.
ResultsExtrapolation performance on the testing data confirmed our network's robustness and ability to generalize to unseen data from different patients, yielding maximum extrapolation errors of 26 HU following the PLTF and 7.
5 HU following the CNN (averaged per target organ).
Degradation of network performance when applied to a geometrically simple phantom confirmed our method's reliance on feature‐contrast relationships in correctly inferring spectral contrast.
Integrating our image domain spectral extrapolation network into a standard dual‐source, dual‐energy processing pipeline for Siemens Flash scanner data yielded spectral CT data with adequate fidelity for the generation of both 50 keV monochromatic images and material decomposition images over a 30‐cm FoV for chain B when only 20 cm of chain B data were available for spectral extrapolation.
ConclusionsEven with a moderate amount of training data, deep learning methods are capable of robustly inferring spectral contrast from feature‐contrast relationships in spectral CT data, leading to spectral extrapolation performance well beyond what may be expected at face value.
Future work reconciling spectral extrapolation results with original projection data is expected to further improve results in outlying and pathological cases.
Related Results
Feasibility of energy-resolved angiography
Feasibility of energy-resolved angiography
<p dir="ltr">Cardiovascular disease (CVD) is the leading cause of death globally, with coronary heart disease being one of the most common types of CVD. Two-dimensional x-ray...
Feasibility of energy-resolved angiography
Feasibility of energy-resolved angiography
<p dir="ltr">Cardiovascular disease (CVD) is the leading cause of death globally, with coronary heart disease being one of the most common types of CVD. Two-dimensional x-ray...
CREATING LEARNING MEDIA IN TEACHING ENGLISH AT SMP MUHAMMADIYAH 2 PAGELARAN ACADEMIC YEAR 2020/2021
CREATING LEARNING MEDIA IN TEACHING ENGLISH AT SMP MUHAMMADIYAH 2 PAGELARAN ACADEMIC YEAR 2020/2021
The pandemic Covid-19 currently demands teachers to be able to use technology in teaching and learning process. But in reality there are still many teachers who have not been able ...
Using dual-energy CT to discriminate sediment facies in a varved sequence 
Using dual-energy CT to discriminate sediment facies in a varved sequence 
The attenuation of X-ray is influenced by the density (electron density, ρe) and the elemental composition (effective atomic number, Zeff) of the object being imaged. The ...
The Application of S‐transform Spectrum Decomposition Technique in Extraction of Weak Seismic Signals
The Application of S‐transform Spectrum Decomposition Technique in Extraction of Weak Seismic Signals
AbstractIn processing of deep seismic reflection data, when the frequency band difference between the weak useful signal and noise both from the deep subsurface is very small and h...
Selection of Injectable Drug Product Composition using Machine Learning Models (Preprint)
Selection of Injectable Drug Product Composition using Machine Learning Models (Preprint)
BACKGROUND
As of July 2020, a Web of Science search of “machine learning (ML)” nested within the search of “pharmacokinetics or pharmacodynamics” yielded over 100...
A method of calibrating effective area of focusing X-ray detector by using normal spectrum of Crab pulsar
A method of calibrating effective area of focusing X-ray detector by using normal spectrum of Crab pulsar
X-ray detector is a core component for X-ray astronomical observation and pulsar navigation.The on-orbit observation performance of X-ray detector will change gradually,owing to th...
Exceptional X-ray activity in BL Lacertae
Exceptional X-ray activity in BL Lacertae
BL Lacertae is a unique blazar for which the X-ray band can cover either the synchrotron or the inverse Compton, or both parts of the broadband spectral energy distribution. In the...