Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Biotin interference in immunoassay: a review for the laboratory scientist

View through CrossRef
The recent FDA Biotin (Vitamin B7): Safety Communication – May Interfere with Lab Tests and A statement from the ACB Scientific Committee regarding biotin/vitamin B7 interference in immunoassays have raised into the laboratory consciousness the need to understand and to manage the issues around biotin interference with some immunoassays and to provide education and advice to health-care providers. In patients who are prescribed biotin or take biotin supplements, biotin has the potential to cause falsely low or falsely high results in immunoassays using streptavidin–biotin binding as part of the assay methodology. Streptavidin–biotin binding is used by many manufacturers; some manufacturers use it for most of their immunoassays, some for a few of their immunoassays and some manufacturers do not use this assay format at all. The direction and magnitude of interference and the concentration of biotin which affects an assay are highly variable and assay specific. There have been many papers and case reports published recently of biotin interference in immunoassay, and biotin interference is probably one of the most difficult types of inference to detect and to obviate. This review will assess the currently available information on this topic and review the steps the laboratory can take to reduce the risk of incorrect patient results being reported.
Title: Biotin interference in immunoassay: a review for the laboratory scientist
Description:
The recent FDA Biotin (Vitamin B7): Safety Communication – May Interfere with Lab Tests and A statement from the ACB Scientific Committee regarding biotin/vitamin B7 interference in immunoassays have raised into the laboratory consciousness the need to understand and to manage the issues around biotin interference with some immunoassays and to provide education and advice to health-care providers.
In patients who are prescribed biotin or take biotin supplements, biotin has the potential to cause falsely low or falsely high results in immunoassays using streptavidin–biotin binding as part of the assay methodology.
Streptavidin–biotin binding is used by many manufacturers; some manufacturers use it for most of their immunoassays, some for a few of their immunoassays and some manufacturers do not use this assay format at all.
The direction and magnitude of interference and the concentration of biotin which affects an assay are highly variable and assay specific.
There have been many papers and case reports published recently of biotin interference in immunoassay, and biotin interference is probably one of the most difficult types of inference to detect and to obviate.
This review will assess the currently available information on this topic and review the steps the laboratory can take to reduce the risk of incorrect patient results being reported.

Related Results

Biotin interference with laboratory test results
Biotin interference with laboratory test results
Introduction: Biotin interference in laboratory tests is a growing concern, particularly due to the widespread use of biotin not only as a therapeutic agent but also as a supplemen...
Application of Thiamine-Biotin Conjugate for Serum Thiamine Levels Measurement
Application of Thiamine-Biotin Conjugate for Serum Thiamine Levels Measurement
ABSTRAK Tiamin berfungsi sebagai koenzim untuk beberapa enzim yang terlibat dalam metabolisme karbohidrat. Mengingat pentingnya peran tiamin, maka dilakukan pengembangan tekn...
The Molecular Environment Modulates CO2 Liberation from Carboxy-Biotin
The Molecular Environment Modulates CO2 Liberation from Carboxy-Biotin
Carboxy-biotin serves as a coenzyme in certain carboxylases, exhibiting the remark- able capability to transfer a carboxy group to specific substrates. This process is made possibl...
7337 High Parathyroid Hormone (PTH) Due To Immunoassay Interference
7337 High Parathyroid Hormone (PTH) Due To Immunoassay Interference
Abstract Disclosure: V.A. Mendpara: None. A.J. McShane: None. L.Z. Khan: None. Background: PTH levels are not always accurate. This case illustrates i...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical activi...
Immunoassay Interference on Thyroid Function Tests During Treatment with Nivolumab
Immunoassay Interference on Thyroid Function Tests During Treatment with Nivolumab
Background: Immune checkpoint inhibitors (ICIs) are associated with several endocrine side effects. In particular, the use of programmed cell death protein-1 (P...

Back to Top