Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
View through CrossRef
Abstract
Background
Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate of complications. In this study, we designed a new type of cannulated screws called degradable magnesium alloy bionic cannulated screws (DMBCS) and our aim was to compare the biomechanical properties of DMBCS, the traditionally used titanium alloy bionic cannulated screws (TBCS) and titanium alloy cannulated screws (TTCS).
Methods
A proximal femur model was established based on CT data of a lower extremity from a voluntary healthy man. Garden type III femoral neck fracture was constructed and fixed with DMBCS, TBCS, and TTCS, respectively. Biomechanical effect which three type of CS models have on femoral neck fracture was evaluated and compared using von Mises stress distribution and displacement.
Results
In the normal model, the maximum stress value of cortical bone and cancellous bone was 76.18 and 6.82 MPa, and the maximum displacement was 5.52 mm. Under 3 different fracture healing status, the stress peak value of the cortical bone and cancellous bone in the DMBCS fixation model was lower than that in the TTCS and TBCS fixation, while the maximum displacement of DMBCS fixation model was slightly higher than that of TTCS and TBCS fixation models. As the fracture heals, stress peak value of the screws and cortical bone of intact models are decreasing, while stress peak value of cancellous bone is increasing initially and then decreasing.
Conclusions
The DMBCS exhibits the superior biomechanical performance than TTCS and TBCS, whose fixation model is closest to the normal model in stress distribution. DMBCS is expected to reduce the rates of post-operative complications with traditional internal fixation and provide practical guidance for the structural design of CS for clinical applications.
Springer Science and Business Media LLC
Title: Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
Description:
Abstract
Background
Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate of complications.
In this study, we designed a new type of cannulated screws called degradable magnesium alloy bionic cannulated screws (DMBCS) and our aim was to compare the biomechanical properties of DMBCS, the traditionally used titanium alloy bionic cannulated screws (TBCS) and titanium alloy cannulated screws (TTCS).
Methods
A proximal femur model was established based on CT data of a lower extremity from a voluntary healthy man.
Garden type III femoral neck fracture was constructed and fixed with DMBCS, TBCS, and TTCS, respectively.
Biomechanical effect which three type of CS models have on femoral neck fracture was evaluated and compared using von Mises stress distribution and displacement.
Results
In the normal model, the maximum stress value of cortical bone and cancellous bone was 76.
18 and 6.
82 MPa, and the maximum displacement was 5.
52 mm.
Under 3 different fracture healing status, the stress peak value of the cortical bone and cancellous bone in the DMBCS fixation model was lower than that in the TTCS and TBCS fixation, while the maximum displacement of DMBCS fixation model was slightly higher than that of TTCS and TBCS fixation models.
As the fracture heals, stress peak value of the screws and cortical bone of intact models are decreasing, while stress peak value of cancellous bone is increasing initially and then decreasing.
Conclusions
The DMBCS exhibits the superior biomechanical performance than TTCS and TBCS, whose fixation model is closest to the normal model in stress distribution.
DMBCS is expected to reduce the rates of post-operative complications with traditional internal fixation and provide practical guidance for the structural design of CS for clinical applications.
Related Results
FEMORAL NECK FRACTURES, EPIDEMIOLOGY, ANATOMICAL DESCRIPTION, MECHANISM OF ACTION, CLASSIFICATION, CLINICAL EVALUATION, IMAGING EVALUATION, TREATMENT AND COMPLICATIONS
FEMORAL NECK FRACTURES, EPIDEMIOLOGY, ANATOMICAL DESCRIPTION, MECHANISM OF ACTION, CLASSIFICATION, CLINICAL EVALUATION, IMAGING EVALUATION, TREATMENT AND COMPLICATIONS
Introduction: Femoral neck fractures (FNF) are frequent and devastating injuries in orthopedics and traumatology. It usually has several therapeutic options depending on the type o...
Comparison of Femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
Comparison of Femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
Abstract
Objective: The purpose of this study was to compare the biomechanical and clinical results of two surgical methods for the treatment of vertical femoral neck fract...
Design, Manufacturing and Characterization of Biodegradable Bone Screw from PLA Prepared by Fused Deposition Modelling (FDM) 3D Printing Technique
Design, Manufacturing and Characterization of Biodegradable Bone Screw from PLA Prepared by Fused Deposition Modelling (FDM) 3D Printing Technique
Biopolymers are utilized extensively in the medical field. The production of biodegradable bone screws for bone implants utilizing biopolymer materials is one of the advances devel...
Safe range of femoral neck system insertion and the risk of perforation
Safe range of femoral neck system insertion and the risk of perforation
Abstract
Background
Internal fixation of the femoral neck carries a risk of perforation due to the presence of the isthmus of the femoral neck. At present, there are few s...
A comparative study of early functional outcomes in undisplaced neck of femur fracture treated with partially threaded and fully threaded cannulated screw fixation in patients above 60 years age
A comparative study of early functional outcomes in undisplaced neck of femur fracture treated with partially threaded and fully threaded cannulated screw fixation in patients above 60 years age
Objective: To compare the partially threaded versus fully threaded cannulated screw fixation methods in stable neck of femur fracture in terms of early functional outcomes in patie...
Study on the method of using absorbable screws combined with cannulated screws to treat calcaneal fractures using talar calcaneal distraction technique
Study on the method of using absorbable screws combined with cannulated screws to treat calcaneal fractures using talar calcaneal distraction technique
Abstract
Background: For intra-articular fractures with displaced posterior articular surface of calcaneus, more and more studies have shown that surgical treatment has bet...
Precision reduction of femoral neck fractures: A novel strategy based on the femoral neck fracture morphology
Precision reduction of femoral neck fractures: A novel strategy based on the femoral neck fracture morphology
Abstract
Background
In femoral neck fractures the secondary damage caused by repeated multiple reductions needs to be prevented. Accordingly, the aim of this study was to a...
Angiographic evaluation of femoral bifurcation in Chinese population
Angiographic evaluation of femoral bifurcation in Chinese population
Objective
Common femoral artery (CFA) access has been proved to be safe with lower risk of complications in percutaneous catheterisation. The femoral head can be ...