Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis

View through CrossRef
Abstract Background Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate of complications. In this study, we designed a new type of cannulated screws called degradable magnesium alloy bionic cannulated screws (DMBCS) and our aim was to compare the biomechanical properties of DMBCS, the traditionally used titanium alloy bionic cannulated screws (TBCS) and titanium alloy cannulated screws (TTCS). Methods A proximal femur model was established based on CT data of a lower extremity from a voluntary healthy man. Garden type III femoral neck fracture was constructed and fixed with DMBCS, TBCS, and TTCS, respectively. Biomechanical effect which three type of CS models have on femoral neck fracture was evaluated and compared using von Mises stress distribution and displacement. Results In the normal model, the maximum stress value of cortical bone and cancellous bone was 76.18 and 6.82 MPa, and the maximum displacement was 5.52 mm. Under 3 different fracture healing status, the stress peak value of the cortical bone and cancellous bone in the DMBCS fixation model was lower than that in the TTCS and TBCS fixation, while the maximum displacement of DMBCS fixation model was slightly higher than that of TTCS and TBCS fixation models. As the fracture heals, stress peak value of the screws and cortical bone of intact models are decreasing, while stress peak value of cancellous bone is increasing initially and then decreasing. Conclusions The DMBCS exhibits the superior biomechanical performance than TTCS and TBCS, whose fixation model is closest to the normal model in stress distribution. DMBCS is expected to reduce the rates of post-operative complications with traditional internal fixation and provide practical guidance for the structural design of CS for clinical applications.
Title: Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
Description:
Abstract Background Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate of complications.
In this study, we designed a new type of cannulated screws called degradable magnesium alloy bionic cannulated screws (DMBCS) and our aim was to compare the biomechanical properties of DMBCS, the traditionally used titanium alloy bionic cannulated screws (TBCS) and titanium alloy cannulated screws (TTCS).
Methods A proximal femur model was established based on CT data of a lower extremity from a voluntary healthy man.
Garden type III femoral neck fracture was constructed and fixed with DMBCS, TBCS, and TTCS, respectively.
Biomechanical effect which three type of CS models have on femoral neck fracture was evaluated and compared using von Mises stress distribution and displacement.
Results In the normal model, the maximum stress value of cortical bone and cancellous bone was 76.
18 and 6.
82 MPa, and the maximum displacement was 5.
52 mm.
Under 3 different fracture healing status, the stress peak value of the cortical bone and cancellous bone in the DMBCS fixation model was lower than that in the TTCS and TBCS fixation, while the maximum displacement of DMBCS fixation model was slightly higher than that of TTCS and TBCS fixation models.
As the fracture heals, stress peak value of the screws and cortical bone of intact models are decreasing, while stress peak value of cancellous bone is increasing initially and then decreasing.
Conclusions The DMBCS exhibits the superior biomechanical performance than TTCS and TBCS, whose fixation model is closest to the normal model in stress distribution.
DMBCS is expected to reduce the rates of post-operative complications with traditional internal fixation and provide practical guidance for the structural design of CS for clinical applications.

Related Results

Safe range of femoral neck system insertion and the risk of perforation
Safe range of femoral neck system insertion and the risk of perforation
Abstract Background Internal fixation of the femoral neck carries a risk of perforation due to the presence of the isthmus of the femoral neck. At present, there are few s...
Precision reduction of femoral neck fractures: A novel strategy based on the femoral neck fracture morphology
Precision reduction of femoral neck fractures: A novel strategy based on the femoral neck fracture morphology
Abstract Background In femoral neck fractures the secondary damage caused by repeated multiple reductions needs to be prevented. Accordingly, the aim of this study was to a...
Angiographic evaluation of femoral bifurcation in Chinese population
Angiographic evaluation of femoral bifurcation in Chinese population
Objective Common femoral artery (CFA) access has been proved to be safe with lower risk of complications in percutaneous catheterisation. The femoral head can be ...

Back to Top