Javascript must be enabled to continue!
Effect of HEMA-Containing and HEMA-Free Adhesives on the Integrity of Deep Proximal Margin Restorations
View through CrossRef
ABSTRACT
Objective:
Resin composite restorations in deep subgingival cavities involving cementum margins often exhibit early adhesive debonding and marginal failure. Conventional resin adhesive systems are prone to hydrolysis in these situations. However, evidence on the optimal adhesive systems for deep margins is limited. Therefore, this study evaluated the effect of HEMA-containing and HEMA-free adhesives in deep proximal margin restorations after simulated long-term aging.
Methods and Materials:
Class II box-only cavities were prepared on the distal surfaces of 48 extracted upper premolars, with the gingival margins placed 2 mm apical to the cemento-enamel junction. The teeth were randomly divided into three study groups (n = 16) based on the type of adhesive system: two-step HEMA-containing, two-step HEMA-free, and one-step HEMA-containing. Cavities were restored using a preheated nanohybrid resin composite and cured using a polywave LED light at 1200 mW/cm
2
. Each group was subdivided into an immediate subgroup (n = 8), in which teeth were examined after 24 hours, and a delayed subgroup (n = 8), in which teeth were examined after an aging process comprising 10,000 thermal cycles (5-55°C). Resin composite/cementum interfaces were evaluated quantitatively by scanning electron microscopy at 200× magnification. Marginal integrity was statistically analyzed by the percentage of continuous margin (%CM).
Results:
The Kruskal-Wallis test revealed that the two-step HEMA-containing and two-step HEMA-free adhesive systems showed significantly better marginal integrity than the one-step HEMA-containing system for both the immediate and aged groups (all
p
< 0.005). A Wilcoxon rank-sum test showed that the aging process affected the one-step HEMA-containing adhesive system (
p
= 0.002), but not the two-step systems (
p
< 0.05).
Conclusion:
Two-step adhesive systems had better performance at cementum margins than the one-step adhesive system. The presence of HEMA in the two-step adhesive did not degrade marginal quality compared to the two-step HEMA-free adhesive systems.
Title: Effect of HEMA-Containing and HEMA-Free Adhesives on the Integrity of Deep Proximal Margin Restorations
Description:
ABSTRACT
Objective:
Resin composite restorations in deep subgingival cavities involving cementum margins often exhibit early adhesive debonding and marginal failure.
Conventional resin adhesive systems are prone to hydrolysis in these situations.
However, evidence on the optimal adhesive systems for deep margins is limited.
Therefore, this study evaluated the effect of HEMA-containing and HEMA-free adhesives in deep proximal margin restorations after simulated long-term aging.
Methods and Materials:
Class II box-only cavities were prepared on the distal surfaces of 48 extracted upper premolars, with the gingival margins placed 2 mm apical to the cemento-enamel junction.
The teeth were randomly divided into three study groups (n = 16) based on the type of adhesive system: two-step HEMA-containing, two-step HEMA-free, and one-step HEMA-containing.
Cavities were restored using a preheated nanohybrid resin composite and cured using a polywave LED light at 1200 mW/cm
2
.
Each group was subdivided into an immediate subgroup (n = 8), in which teeth were examined after 24 hours, and a delayed subgroup (n = 8), in which teeth were examined after an aging process comprising 10,000 thermal cycles (5-55°C).
Resin composite/cementum interfaces were evaluated quantitatively by scanning electron microscopy at 200× magnification.
Marginal integrity was statistically analyzed by the percentage of continuous margin (%CM).
Results:
The Kruskal-Wallis test revealed that the two-step HEMA-containing and two-step HEMA-free adhesive systems showed significantly better marginal integrity than the one-step HEMA-containing system for both the immediate and aged groups (all
p
< 0.
005).
A Wilcoxon rank-sum test showed that the aging process affected the one-step HEMA-containing adhesive system (
p
= 0.
002), but not the two-step systems (
p
< 0.
05).
Conclusion:
Two-step adhesive systems had better performance at cementum margins than the one-step adhesive system.
The presence of HEMA in the two-step adhesive did not degrade marginal quality compared to the two-step HEMA-free adhesive systems.
Related Results
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Abstract
Funding Acknowledgements
Type of funding sources: None.
INTRODUCTION Patients with heart failure (HF)...
Primary PCI: a reasonable treatment for STEMI care during the COVID-19 pandemic
Primary PCI: a reasonable treatment for STEMI care during the COVID-19 pandemic
Abstract
Funding Acknowledgements
Type of funding sources: None.
Introduction
...
HEMA-free versus HEMA-containing adhesive systems: a systematic review
HEMA-free versus HEMA-containing adhesive systems: a systematic review
Abstract
Background
Hydrophilic monomer 2-hydroxyethyl methacrylate (HEMA)-free adhesive systems are gaining increasing popularity nowadays. Alt...
2‐Hydroxyethyl methacrylate (HEMA): A clinical review of contact allergy and allergic contact dermatitis. Part 2. Cross‐ and co‐sensitization, other skin reactions to HEMA, position of HEMA among (meth)acrylates, sensitivity as screening agent, presence o
2‐Hydroxyethyl methacrylate (HEMA): A clinical review of contact allergy and allergic contact dermatitis. Part 2. Cross‐ and co‐sensitization, other skin reactions to HEMA, position of HEMA among (meth)acrylates, sensitivity as screening agent, presence o
AbstractThis is the second part of a literature review of the clinical aspects of contact allergy to and allergic contact dermatitis from 2‐hydroxyethyl methacrylate (HEMA). Topics...
Comparison of Shear Bond Strength Between HEMA-Based and Non-HEMA Bonding Agents on Dentin Surface
Comparison of Shear Bond Strength Between HEMA-Based and Non-HEMA Bonding Agents on Dentin Surface
Background: Resin composite restorative materials have become increasingly popular in dental practice in recent decades due to their esthetic properties that meet patient demands. ...
Six-year Clinical Evaluation of Packable Composite Restorations
Six-year Clinical Evaluation of Packable Composite Restorations
SUMMARY
Objective: For decades, resin composites have been used with increasing frequency as posterior restorative materials, because of the demand for aesthetic restoratio...
Moisture Sensitive Adhesives and Flooring Adhesive Failures
Moisture Sensitive Adhesives and Flooring Adhesive Failures
Over the last decade, changes in environmental government regulations have necessitated the reformulation of many historically durable adhesives used in the application of flooring...
Radiographic Secondary Caries Prevalence in Teeth with Clinically Defective Restorations
Radiographic Secondary Caries Prevalence in Teeth with Clinically Defective Restorations
Decisions to replace existing restorations are often based on clinical findings of margin discrepancies and other restoration defects. Previous studies have suggested that such fin...

