Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Study To Compare The Accuracy Of Interpupillary Distance Measured Using Interpupillary Distance Ruler With That Of Neidek Autorefractometer

View through CrossRef
The purpose of this study is to compare the accuracy of interpupillary  distance (IPD) measured using an Interpupillary distance (IPD) ruler with that of a needed auto refractometer. The validity of both the test are compared and normal data for each individual were established. To assess the accuracy of Interpupillary distance measured using IPD ruler with that of Neidek auto refractometer. The IPD is a very cardial measurement that had to be calculated for patients with spectacle corrections before selecting frames. A cross-sectional study involving 150 subjects was conducted in the OPD of the Department of Ophthalmology in a Medical college in Chennai. Interpupillary distances had been measured using the IPD ruler and the Neidek auto refractometer, during a period of 3 months.IPD measurements from 150 subjects were obtained using IPD ruler and Neidek auto refractometer. From the study, it was found that there is a no significant difference between the IPD measured using IPD ruler with that of Neidek auto refractometer.  IPD measured using IPD ruler is accurate to the IPD measured using Neidek auto refractometer.
Title: A Study To Compare The Accuracy Of Interpupillary Distance Measured Using Interpupillary Distance Ruler With That Of Neidek Autorefractometer
Description:
The purpose of this study is to compare the accuracy of interpupillary  distance (IPD) measured using an Interpupillary distance (IPD) ruler with that of a needed auto refractometer.
The validity of both the test are compared and normal data for each individual were established.
To assess the accuracy of Interpupillary distance measured using IPD ruler with that of Neidek auto refractometer.
The IPD is a very cardial measurement that had to be calculated for patients with spectacle corrections before selecting frames.
A cross-sectional study involving 150 subjects was conducted in the OPD of the Department of Ophthalmology in a Medical college in Chennai.
Interpupillary distances had been measured using the IPD ruler and the Neidek auto refractometer, during a period of 3 months.
IPD measurements from 150 subjects were obtained using IPD ruler and Neidek auto refractometer.
From the study, it was found that there is a no significant difference between the IPD measured using IPD ruler with that of Neidek auto refractometer.
  IPD measured using IPD ruler is accurate to the IPD measured using Neidek auto refractometer.

Related Results

Correlation Between Interpupillary Distance and Reaction Time Among Male and Female Kabaddi Players
Correlation Between Interpupillary Distance and Reaction Time Among Male and Female Kabaddi Players
Keywords: Interpupillary Distance, Reaction Time, Kabaddi Players, Sports Vision, Motor Response  Introduction“Efficient eye movements help athletes gather precise visual cues from...
Levitating Control System of Maglev Ruler Based on Active Disturbance Rejection Controller
Levitating Control System of Maglev Ruler Based on Active Disturbance Rejection Controller
The autonomous displacement and displacement measurement functions of the maglev ruler are performed by the mover core. The stability of the four magnetic field in air gaps and the...
O TITULATURAMA KRALjA MILUTINA
O TITULATURAMA KRALjA MILUTINA
The shortest titulature would consist of the ruler's name and title. Broader ones contained territorial indicators – namely lands ruled by the ruler, the ruler's byname and formula...
Legalist philosophy, Chinese
Legalist philosophy, Chinese
Legalist philosophy constitutes one of the three dominant streams of Chinese philosophy along with Confucian and Daoist philosophies. It aims to establish objective, impartial and ...
Title of Lithuanian Ruler Vytautas: When did Vytautas Start to Title Himself as the Grand Duke?
Title of Lithuanian Ruler Vytautas: When did Vytautas Start to Title Himself as the Grand Duke?
Lithuanian ruler until the Krėva union used to have different titles. Although, in a variety of names, the title of the Lithuanian ruler was superior to those of the ruling dynasty...
METODE CEK ANTARA RULER CALIBRATOR UNTUK JAMINAN MUTU INTERNAL KALIBRASI
METODE CEK ANTARA RULER CALIBRATOR UNTUK JAMINAN MUTU INTERNAL KALIBRASI
Abstrak-- Salah satu standar panjang yang ada di laboratorium kalibrasi adalah ruler calibrator yang digunakan untuk mengkalibrasi alat ukur besaran panjang konvensional yaitu beru...
The Image of a Christian Ruler in Baroque Sermons: Wladyslaw Vasa
The Image of a Christian Ruler in Baroque Sermons: Wladyslaw Vasa
Building on five occasional sermons in Polish dedicated to Wladislaw Vasa (1595–1648), King of Poland and Grand Duke of Lithuania, by Jesuit Jakub Olszewski (1585–1634), Dominican ...

Back to Top