Exergy Analysis on an Innovative Vapor-Compression Ejector Heat Pump Water Heater

View through CrossRef
Abstract Ejector-driven systems are thermally operated and capable of utilizing excess thermal energy to aid in boosting the overall efficiency of the system. Traditionally, ejectors have been implemented into systems for cooling purposes, however, recent studies have demonstrated their potential to increase the efficiency in heat pump systems. In this study a theoretical model is developed, its performance is modeled, and an exergy analysis is performed on an innovative vapor compression ejector heat pump (VCEHP) for the purposes of water heating. The analysis is performed assuming the evaporator temperature of 6.5 °C, and a low temperature evaporator (LTE) temperature of 20 °C, for condenser outlet temperature range of 40–60 °C, with R134a acting as the working fluid. The ejector model incorporated was compared to previous experimental studies utilizing R134a, and the predicted coefficient of performance (COP) and back pressures to within 4.01%. The results of the VCEHP are compared to that of a traditional vapor compression heat pump (VCHP) water heater. The theoretical results have shown that the incorporation of the ejector can lead to a 22.78% increase in the system heating COP.
Title: Exergy Analysis on an Innovative Vapor-Compression Ejector Heat Pump Water Heater
Description:
Abstract Ejector-driven systems are thermally operated and capable of utilizing excess thermal energy to aid in boosting the overall efficiency of the system.
Traditionally, ejectors have been implemented into systems for cooling purposes, however, recent studies have demonstrated their potential to increase the efficiency in heat pump systems.
In this study a theoretical model is developed, its performance is modeled, and an exergy analysis is performed on an innovative vapor compression ejector heat pump (VCEHP) for the purposes of water heating.
The analysis is performed assuming the evaporator temperature of 6.
5 °C, and a low temperature evaporator (LTE) temperature of 20 °C, for condenser outlet temperature range of 40–60 °C, with R134a acting as the working fluid.
The ejector model incorporated was compared to previous experimental studies utilizing R134a, and the predicted coefficient of performance (COP) and back pressures to within 4.
01%.
The results of the VCEHP are compared to that of a traditional vapor compression heat pump (VCHP) water heater.
The theoretical results have shown that the incorporation of the ejector can lead to a 22.
78% increase in the system heating COP.

Related Results

Exergy Efficiency and COP Improvement of a CO2 Transcritical Heat Pump System by Replacing an Expansion Valve with a Tesla Turbine
Exergy Efficiency and COP Improvement of a CO2 Transcritical Heat Pump System by Replacing an Expansion Valve with a Tesla Turbine
The heat pump system has been widely used in residential and commercial applications due to its attractive advantages of high energy efficiency, reliability, and environmental impa...
OPTIMAL DESIGN OF EJECTOR BELT SEEDLING COLLECTING MECHANISM BASED ON EDEM
OPTIMAL DESIGN OF EJECTOR BELT SEEDLING COLLECTING MECHANISM BASED ON EDEM
In the seedling extraction mechanism of the ejection type, because the ejector rod is in direct contact with the seedling substrate, the fragmentation rate of the seedling is high,...
The Differential Impact of Various Injection Pressures on the Exergy of a Diesel Engine Using Biodiesel-Diesel Fuel Blends
The Differential Impact of Various Injection Pressures on the Exergy of a Diesel Engine Using Biodiesel-Diesel Fuel Blends
Contrary to energy, exergy may be destroyed due to irreversibility. Exergy analysis can be used to reveal the location, and amount of energy losses of engines. Despite the importan...
Using Exergy-Based Metrics in Assessing Sustainability of Fossil-Fueled Thermal Energy Systems
Using Exergy-Based Metrics in Assessing Sustainability of Fossil-Fueled Thermal Energy Systems
This chapter examines the importance of exergy-based parameters like exergy efficiency, environmental compatibility, sustainability index, depletion number, and improvement potenti...
Theoretical analysis and experimental investigation of ejector heat pumps and its water heating applications
Theoretical analysis and experimental investigation of ejector heat pumps and its water heating applications
This dissertation presents both theoretical and experimental work on ejector heat pump (EHP) systems and its water heating applications. The main goal is to improve performance, id...
Exergy in School?
Exergy in School?
Students at all levels of physics instruction have difficulties dealing with energy, work and heat in general and, in particular, with the concepts of efficiency and ideal heat eng...
Exergy Flows inside a One Phase Ejector for Refrigeration Systems
Exergy Flows inside a One Phase Ejector for Refrigeration Systems
The evaluation of the thermodynamic performance of the mutual transformation of different kinds of exergy linked to the intensive thermodynamic parameters of the flow inside the ej...
Operation Rule of Steam Ejector and Influence Analysis of Ejection Position
Operation Rule of Steam Ejector and Influence Analysis of Ejection Position
In order to analyze the operation rule of steam ejector used in sewage treatment field, this paper established the mathematical model of steam ejector, simulated the internal flow ...

Back to Top