Collapse of an RC Building Under Construction with a Flat Slab System: Reasons, Calculations, and FE Simulations

View through CrossRef
The using of flat slab systems is a common structural solution for residential and commercial buildings as they are a cost-effective structural solution that simplifies and speeds up the construction phase. However, the flat slab systems have complex behavior, particularly in the slab–column connection zones, because of punching shear. Therefore, to prevent brittle flat slab collapse because of punching shear, there are some conditions which must be met in regulations such as Eurocode 2, American Concrete Institute’s Code, and Türkiye Building Earthquake Code—2018. Flat slab collapses because of punching shear can be caused by deficiencies in the design phase as well as deficiencies in the construction phase. The purpose of this study is to investigate the causes of flat slab collapses due to punching shear, focusing on whether these failures arise from design or construction deficiencies. The study highlights the importance of adhering to regulations to prevent brittle flat slab collapses. A case study of an actual building collapse due to punching shear was conducted. Theoretical punching shear strength was calculated based on the Türkiye Building Earthquake Code—2018. A finite element model of the collapsed part of the building was created, and collapse mechanism simulations were performed. It was examined whether the punching collapse mechanism was caused by deficiencies in the design or the construction phase. The findings revealed the critical role of proper design phases and construction practices in ensuring structural integrity.
Title: Collapse of an RC Building Under Construction with a Flat Slab System: Reasons, Calculations, and FE Simulations
Description:
The using of flat slab systems is a common structural solution for residential and commercial buildings as they are a cost-effective structural solution that simplifies and speeds up the construction phase.
However, the flat slab systems have complex behavior, particularly in the slab–column connection zones, because of punching shear.
Therefore, to prevent brittle flat slab collapse because of punching shear, there are some conditions which must be met in regulations such as Eurocode 2, American Concrete Institute’s Code, and Türkiye Building Earthquake Code—2018.
Flat slab collapses because of punching shear can be caused by deficiencies in the design phase as well as deficiencies in the construction phase.
The purpose of this study is to investigate the causes of flat slab collapses due to punching shear, focusing on whether these failures arise from design or construction deficiencies.
The study highlights the importance of adhering to regulations to prevent brittle flat slab collapses.
A case study of an actual building collapse due to punching shear was conducted.
Theoretical punching shear strength was calculated based on the Türkiye Building Earthquake Code—2018.
A finite element model of the collapsed part of the building was created, and collapse mechanism simulations were performed.
It was examined whether the punching collapse mechanism was caused by deficiencies in the design or the construction phase.
The findings revealed the critical role of proper design phases and construction practices in ensuring structural integrity.

Related Results

Seismic Response Optimization of RC Slabs: Influence of Opening Location, Size, and Geometry on Structural Performance
Seismic Response Optimization of RC Slabs: Influence of Opening Location, Size, and Geometry on Structural Performance
In this research, the influence of the location, area and shape of the openings on the seismic behavior and performance of the concrete slab roof was evaluated and studied using th...
A Comparative Study of Flat Slab and Waffle Slab Structure for Efficiency of Convention Building Slab System
A Comparative Study of Flat Slab and Waffle Slab Structure for Efficiency of Convention Building Slab System
In the world of construction, aesthetic has become an important factor that must be considered. The aesthetic elements consist of wholeness, prominence and balance. However, aesthe...
Detached Tonga slab in the mantle transition zone imaged by stress variations of deep-focus earthquakes
Detached Tonga slab in the mantle transition zone imaged by stress variations of deep-focus earthquakes
Tonga is a part of Tonga-Kermadec, the 2,550 km long subduction system in SW Pacific. It represents a convergent plate boundary and the outcome of the Pacific plate submerging unde...
Comparative Study of and Voided Slab System and Conventional RCC Slab
Comparative Study of and Voided Slab System and Conventional RCC Slab
This paper presents the flexural capacities of R.C.two-way hollow flat slabs with plastic voids. Recently, various types of slab systems which can reduce the self-weight of slabs h...
Study on the influencing factors and evolution of loess bank collapse with physical modelling
Study on the influencing factors and evolution of loess bank collapse with physical modelling
Abstract Background Reservoir bank collapse in loess areas may lead to the siltation of reservoir and bank retreat. Therefore, the study of reservoi...
EXPERIMENTAL RESEARCH ON REINFORCED CONCRETE SLABS WITH LOADS FROM COLUMN PLACED ON THE SLAB
EXPERIMENTAL RESEARCH ON REINFORCED CONCRETE SLABS WITH LOADS FROM COLUMN PLACED ON THE SLAB
Slabs made of reinforced concrete often get subjected to loads that are distributed uniformly across the whole surface of the slab. On the other hand, there are situations in which...
COMBINED SLAB-PILE FOUNDATION
COMBINED SLAB-PILE FOUNDATION
Solid reinforced concrete slab foundations are commonly employed in the construction of multi-story frame and panel buildings on natural grounds, as well as in industrial structure...