Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

AN EARLY VALIDATION OF IMAGE PROCESSING TECHNIQUE FOR FLATNESS MEASUREMENT

View through CrossRef
<p>An experimental validation of flatness measurement based on image processing technique has been performed.  The purpose of this study is to know the performance of the image processing technique in the flatness measurement. In addition, this technique will be used as development of current measurement technique that is performed manually. The advantage of using this method is that in the future the measurement system will run semi-automatically, so it can increase the capacity. This study is used 3 samples of optical flat with different in diameter (i.e. 25 mm, 45 mm, and 75 mm). The validation has been performed by comparing measurement results of the image processing technique and the manual technique through degree of equivalence evaluation. The error numbers based on the degree of equivalence criteria between the image processing technique and the manual technique for the flatness measurement of 25 mm, 45 mm, and 75 mm are 0.02, 0.09, and 0.11 respectively. According to those error numbers, the image processing technique measurement results is in agreement with the manual technique. Moreover, those results have validated that the image processing technique has good performance and can potentially be implemented to the flatness measurement.</p>
Title: AN EARLY VALIDATION OF IMAGE PROCESSING TECHNIQUE FOR FLATNESS MEASUREMENT
Description:
<p>An experimental validation of flatness measurement based on image processing technique has been performed.
  The purpose of this study is to know the performance of the image processing technique in the flatness measurement.
In addition, this technique will be used as development of current measurement technique that is performed manually.
The advantage of using this method is that in the future the measurement system will run semi-automatically, so it can increase the capacity.
This study is used 3 samples of optical flat with different in diameter (i.
e.
25 mm, 45 mm, and 75 mm).
The validation has been performed by comparing measurement results of the image processing technique and the manual technique through degree of equivalence evaluation.
The error numbers based on the degree of equivalence criteria between the image processing technique and the manual technique for the flatness measurement of 25 mm, 45 mm, and 75 mm are 0.
02, 0.
09, and 0.
11 respectively.
According to those error numbers, the image processing technique measurement results is in agreement with the manual technique.
Moreover, those results have validated that the image processing technique has good performance and can potentially be implemented to the flatness measurement.
</p>.

Related Results

Latest advancement in image processing techniques
Latest advancement in image processing techniques
Image processing is method of performing some operations on an image, for enhancing the image or for getting some information from that image, or for some other applications is not...
New Method of Plane to Plane Parallelism Error Measurement Based on Flatness Plane
New Method of Plane to Plane Parallelism Error Measurement Based on Flatness Plane
Measurement of parallelism error is one of important icon in the measurement of orientation tolerances. This paper presents new method of parallelism error measurement and is based...
Flatness properties of S-posets with an approach to down-closed subposets
Flatness properties of S-posets with an approach to down-closed subposets
In this paper, we investigate the notion of dc-po-flat [Formula: see text]-posets as the ones for which the associated tensor functors transfer merely down-closed embeddings (embed...
Validation in Doctoral Education: Exploring PhD Students’ Perceptions of Belonging to Scaffold Doctoral Identity Work
Validation in Doctoral Education: Exploring PhD Students’ Perceptions of Belonging to Scaffold Doctoral Identity Work
Aim/Purpose: The aim of this article is to make a case of the role of validation in doctoral education. The purpose is to detail findings from three studies which explore PhD stude...
Flatness Control Strategy Based on Delay Compensation for Cold Rolling Mill
Flatness Control Strategy Based on Delay Compensation for Cold Rolling Mill
In order to improve the feedback stability of flatness control system during the acceleration and deceleration rolling process, the structure and corresponding optimization model o...
Research and Application of Dynamic Substitution Control of Actuators in Flatness Control of Cold Rolling Mill
Research and Application of Dynamic Substitution Control of Actuators in Flatness Control of Cold Rolling Mill
AbstractThe work roll bending control has a strong ability to eliminate the symmetrical flatness defects of strip. However, if the incoming strip is coming with severe symmetrical ...
Influence of Process Parameters on Flatness During Single-Track Laser Cladding
Influence of Process Parameters on Flatness During Single-Track Laser Cladding
During the laser cladding process, poor flatness of the cladding track can cause the surface structure to be uneven or corrugated, affecting the geometrical accuracy of the workpie...
Effect of Dose Rate and Detector Speed Variation on Beam Profile Characteristic in Radiotherapy Dosimetry
Effect of Dose Rate and Detector Speed Variation on Beam Profile Characteristic in Radiotherapy Dosimetry
flatness and symmetry of the beam profile is essential in radiotherapy quality assurance because these parameters directly affect dose accuracy, treatment safety, and clinical outc...

Back to Top