Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Corrosion Inhibition Efficiencies of Polymeric Materials on Alloy Steel in Dilute Hydrochloric Acid and Sodium Hydroxide Solutions at Ambient Temperature

View through CrossRef
A corrosion control test was conducted on alloy steel, using polymeric coatings (polyurethane, bitumen (medium airing), and high-density polyethylene) in dilute HCl solutions of pH values 4, 7, and 12, respectively for acid, neutral and alkaline solutions at ambient temperature. In the study, Eighty-four coupons of alloy steel were used. The coupons were mechanized, ground, polished, etched with natal, and weighed using a digital weighing balance (Beva 206B). The mass of each coupon was recorded according to the tag number on them. Twenty-one of the coupons were coated with polyurethane, 21 coated with medium curing bitumen (MC), and 21 coated with high-density polyethylene, while 21 were left uncoated. Seven polyurethane-coated samples, bitumen coating, and uncoated coupons were suspended in dilute HCl solutions of pH values 4, 7, and 12. Every week, one sample is taken from each of the solutions, the coatings and the corrosion products were removed, and the coupons were etched with natal. Then the coupons were reweighed, and their masses were recorded in accordance with their tag number. The weight loss per unit area of the coupons, corrosion rate, and percentage corrosion inhibition efficiencies of the coatings was calculated over seven weeks. The results obtained were tabulated and represented graphically. From the results obtained, it is seen that the corrosion inhibition efficiency of polyurethane coatings is higher compared with bitumen and polyethylene. It is also seen from the graphs that the corrosion rate of the coupons is higher in acid, a little bit lower in alkaline, and much lower in neutral solution. It is also observed that the corrosion rates fall with time as the inhibition efficiency also falls with time.
Title: Corrosion Inhibition Efficiencies of Polymeric Materials on Alloy Steel in Dilute Hydrochloric Acid and Sodium Hydroxide Solutions at Ambient Temperature
Description:
A corrosion control test was conducted on alloy steel, using polymeric coatings (polyurethane, bitumen (medium airing), and high-density polyethylene) in dilute HCl solutions of pH values 4, 7, and 12, respectively for acid, neutral and alkaline solutions at ambient temperature.
In the study, Eighty-four coupons of alloy steel were used.
The coupons were mechanized, ground, polished, etched with natal, and weighed using a digital weighing balance (Beva 206B).
The mass of each coupon was recorded according to the tag number on them.
Twenty-one of the coupons were coated with polyurethane, 21 coated with medium curing bitumen (MC), and 21 coated with high-density polyethylene, while 21 were left uncoated.
Seven polyurethane-coated samples, bitumen coating, and uncoated coupons were suspended in dilute HCl solutions of pH values 4, 7, and 12.
Every week, one sample is taken from each of the solutions, the coatings and the corrosion products were removed, and the coupons were etched with natal.
Then the coupons were reweighed, and their masses were recorded in accordance with their tag number.
The weight loss per unit area of the coupons, corrosion rate, and percentage corrosion inhibition efficiencies of the coatings was calculated over seven weeks.
The results obtained were tabulated and represented graphically.
From the results obtained, it is seen that the corrosion inhibition efficiency of polyurethane coatings is higher compared with bitumen and polyethylene.
It is also seen from the graphs that the corrosion rate of the coupons is higher in acid, a little bit lower in alkaline, and much lower in neutral solution.
It is also observed that the corrosion rates fall with time as the inhibition efficiency also falls with time.

Related Results

Investigating the Effect of High Pressures and Temperatures on Corrosion Inhibition for Water-Based Muds
Investigating the Effect of High Pressures and Temperatures on Corrosion Inhibition for Water-Based Muds
Corrosion is defined as gradual degradation of metal caused by a chemical or electrochemical reaction with its environment. In oil and gas sector, components can corrode at any sta...
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Abstract Introduction Among the most frequently used anticoagulants in hematological testing are tetra-acetic acid (EDTA), sodium citrate, and sodium heparin. However, there is a n...
Spectral Analysis Of CO2 Corrosion Product Scales On 13Cr Tubing Steel
Spectral Analysis Of CO2 Corrosion Product Scales On 13Cr Tubing Steel
Abstract CO2 corrosion product scales formed on 13Cr tubing steel in autoclave and in the simulated corrosion environment of oil field are investigated in the pap...
Laboratory Studies On Alkaline Waterflooding
Laboratory Studies On Alkaline Waterflooding
Campbell, Thomas C. and Krumrine, Paul H., Members SPE-AIME, PQ Corp., Research and Development Center PQ Corp., Research and Development Center Copyright 1979, American Institute ...
Inhibition of aluminium corrosion using phthalocyanines - Experimental and computational studies
Inhibition of aluminium corrosion using phthalocyanines - Experimental and computational studies
Metal deterioration over time is a process known as corrosion, an electrochemical process, which can occur by surface chemical actions on metals by its environment. Metal corrosion...
Corrosion Of Copper-Base Alloys In A Geothermal Brine
Corrosion Of Copper-Base Alloys In A Geothermal Brine
Abstract The geothermal environment and the experimental procedures and schedules for corrosion tests of copper-base procedures and schedules for corrosion tests ...
Characterization of Biofilm Formation and Coating Degradation By Electrochemical Impedance Spectroscopy
Characterization of Biofilm Formation and Coating Degradation By Electrochemical Impedance Spectroscopy
Recent findings showed severe localized corrosion of submerged steel bridge piles in a Florida bridge and was associated with microbial activity in presence of marine foulers (Perm...
Preventive Corrosion Engineering in Crude Oil Production
Preventive Corrosion Engineering in Crude Oil Production
ABSTRACT A technique is presented that can be used to determine the produced water level in crude oil production where accelerated corrosion of steel will occur (...

Back to Top