Opposite evolution on voltage and thickness from paroxysmal to persistent AF

View through CrossRef
Abstract Background There is a controversy about correlation between voltage and thickness in the atrial myocardium and their evolution from paroxysmal to persistent atrial fibrillation (AF). Purpose This is an observational study to compare voltage and thickness of different areas on the left atrium in paroxysmal and persistent atrial fibrillation. Methods Twenty-one patients underwent atrial fibrillation ablation. Points with electrical information from an electroanatiomical map in sinus rhythym were acquiered during the ablation procedure covering the whole atrial surface. CT was acquired in all patients before the procedure and endo- and epicardium from the atrium was segmented for the atrial thickness calculation. All the points from the electromecanical map were projected on the thickness map to have both information on the same location. 3D atrium was segmented in 5 areas for the analysis: Lateral, Anterior, Septal, Inferior-Posterior and Superior-Posterior (Figure 1). Voltage and thickness values among different areas and between AF type were compared. Results 11 paroxysmal and 10 persistent AF patients were analyzed acquiring 452±207 points per patient and 1897±750 points per area. There was no linear correlation between voltage and thickness comparing all the patients nor among different areas nor between AF type (R<0.2 in all cases). Regarding paroxysmal AF patients, septum showed significatly lower voltage compared with the other segments, posterior, lateral, anterior and roof (1.3±1.4, 2±1.8, 2±1.6, 1.7±1.5, 2±1.6, P<0.001). Posterior segment showed the highest voltage. The thickness analysis showed the septum segment as thinner segment and lateral as thicker segment (1.3±1.5,1.7±0.8, P<0.001) (Figure 2). Regarding persisten AF patients: septum showed significatly lower voltage compared with the other segments, posterior, lateral, anterior and roof who shows higher voltage (1±0.8*, 1.5±1.2, 1.9±1.7, 1.5±1.4, 2±1.6) (Figure 2). The thickness analysis showed the anterior segment as thinner segment and lateral as the thickest segment (1.6±0.8, 1.9±0.9 (P<0.001), different like on paroxysmal AF population. Comparing voltage and thicknes between paroxysmal and persistent AF, all the segments on persistent population showed lower voltage values, with significant differences on septal, posterior and anterior walls (1±0.8 vs 1.3±1.4, 1.5±1.2 vs 2±1.8, 1.5±1.4 vs 1.7±1.5, P<0.001). On the other hand, all segments on persistent population showed statisticaly signignificant thicker myocardium in camparison with paroxysmal population (Figure 2). Conclusions According to our findings, there is no linear correlation between voltage and thickness. Persistent AF atria show thicker walls but with lower voltages in comparison with paroxysmal AF atria. Funding Acknowledgement Type of funding sources: None.
Title: Opposite evolution on voltage and thickness from paroxysmal to persistent AF
Description:
Abstract Background There is a controversy about correlation between voltage and thickness in the atrial myocardium and their evolution from paroxysmal to persistent atrial fibrillation (AF).
Purpose This is an observational study to compare voltage and thickness of different areas on the left atrium in paroxysmal and persistent atrial fibrillation.
Methods Twenty-one patients underwent atrial fibrillation ablation.
Points with electrical information from an electroanatiomical map in sinus rhythym were acquiered during the ablation procedure covering the whole atrial surface.
CT was acquired in all patients before the procedure and endo- and epicardium from the atrium was segmented for the atrial thickness calculation.
All the points from the electromecanical map were projected on the thickness map to have both information on the same location.
3D atrium was segmented in 5 areas for the analysis: Lateral, Anterior, Septal, Inferior-Posterior and Superior-Posterior (Figure 1).
Voltage and thickness values among different areas and between AF type were compared.
Results 11 paroxysmal and 10 persistent AF patients were analyzed acquiring 452±207 points per patient and 1897±750 points per area.
There was no linear correlation between voltage and thickness comparing all the patients nor among different areas nor between AF type (R<0.
2 in all cases).
Regarding paroxysmal AF patients, septum showed significatly lower voltage compared with the other segments, posterior, lateral, anterior and roof (1.
3±1.
4, 2±1.
8, 2±1.
6, 1.
7±1.
5, 2±1.
6, P<0.
001).
Posterior segment showed the highest voltage.
The thickness analysis showed the septum segment as thinner segment and lateral as thicker segment (1.
3±1.
5,1.
7±0.
8, P<0.
001) (Figure 2).
Regarding persisten AF patients: septum showed significatly lower voltage compared with the other segments, posterior, lateral, anterior and roof who shows higher voltage (1±0.
8*, 1.
5±1.
2, 1.
9±1.
7, 1.
5±1.
4, 2±1.
6) (Figure 2).
The thickness analysis showed the anterior segment as thinner segment and lateral as the thickest segment (1.
6±0.
8, 1.
9±0.
9 (P<0.
001), different like on paroxysmal AF population.
Comparing voltage and thicknes between paroxysmal and persistent AF, all the segments on persistent population showed lower voltage values, with significant differences on septal, posterior and anterior walls (1±0.
8 vs 1.
3±1.
4, 1.
5±1.
2 vs 2±1.
8, 1.
5±1.
4 vs 1.
7±1.
5, P<0.
001).
On the other hand, all segments on persistent population showed statisticaly signignificant thicker myocardium in camparison with paroxysmal population (Figure 2).
Conclusions According to our findings, there is no linear correlation between voltage and thickness.
Persistent AF atria show thicker walls but with lower voltages in comparison with paroxysmal AF atria.
Funding Acknowledgement Type of funding sources: None.

Related Results

Modelado de un Recuperador Dinámico de Tensión para el Mejoramiento de la Calidad de la Onda de Tensión
Modelado de un Recuperador Dinámico de Tensión para el Mejoramiento de la Calidad de la Onda de Tensión
[1]          R. C. Dugan, H. W. Beaty, y S. Santoso, Electrical Power Systems Quality, Third edition. Tata McGraw Hill Education, 2012.[2]          J. Arrilaga y N. R. Watson, Powe...
Incidence of Benign Paroxysmal Positional Vertigo and Course of Treatment Following Mild Head Trauma—Is It Worth Looking For?
Incidence of Benign Paroxysmal Positional Vertigo and Course of Treatment Following Mild Head Trauma—Is It Worth Looking For?
BACKGROUND: This study aimed to identify the incidence of benign paroxysmal positional vertigo following head trauma. METHODS: This study is a prospective cross-sectional study. In...
Exercise capacity and paroxysmal atrial fibrillation in patients with hypertrophic cardiomyopathy
Exercise capacity and paroxysmal atrial fibrillation in patients with hypertrophic cardiomyopathy
Background Atrial fibrillation (AF) is the most common arrhythmia among patients with hypertrophic cardiomyopathy (HCM). The relationship between paroxysmal AF an...
Angiotensin receptor-neprilysin inhibitor delays progression from paroxysmal to persistent atrial fibrillation
Angiotensin receptor-neprilysin inhibitor delays progression from paroxysmal to persistent atrial fibrillation
AbstractProgression from paroxysmal to persistent atrial fibrillation (AF) is linked to adverse clinical outcomes. The present study sought to clarify whether angiotensin receptor-...
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Buck-boost Converter is the device with the function to convert DC Voltage input to the setpoint DC Voltage output. Buck-boost converter can be used for regulating unstable voltage...
Control and modulation of modular multilevel converters
Control and modulation of modular multilevel converters
The integration of renewable energy sources in the electrical grid is reducing our dependence on fossil fuels. However, to ensure feasibility and reliability of distributed energy ...

Back to Top