The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study

View through CrossRef
Face scanners promise wide applications in medicine and dentistry, including facial recognition, capturing facial emotions, facial cosmetic planning and surgery, and maxillofacial rehabilitation. Higher accuracy improves the quality of the data recorded from the face scanner, which ultimately, will improve the outcome. Although there are various face scanners available on the market, there is no evidence of a suitable face scanner for practical applications. The aim of this in vitro study was to analyze the face scans obtained from four scanners; EinScan Pro (EP), EinScan Pro 2X Plus (EP+) (Shining 3D Tech. Co., Ltd. Hangzhou, China), iPhone X (IPX) (Apple Store, Cupertino, CA, USA), and Planmeca ProMax 3D Mid (PM) (Planmeca USA, Inc. IL, USA), and to compare scans obtained from various scanners with the control (measured from Vernier caliper). This should help to identify the appropriate scanner for face scanning. A master face model was created and printed from polylactic acid using the resolution of 200 microns on x, y, and z axes and designed in Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). The face models were 3D scanned with four scanners, five times, according to the manufacturer’s recommendations; EinScan Pro (Shining 3D Tech. Co., Ltd. Hangzhou, China), EinScan Pro 2X Plus (Shining 3D Tech. Co., Ltd. Hangzhou, China) using Shining Software, iPhone X (Apple Store, Cupertino, CA, USA) using Bellus3D Face Application (Bellus3D, version 1.6.2, Bellus3D, Inc. Campbell, CA, USA), and Planmeca ProMax 3D Mid (PM) (Planmeca USA, Inc. IL, USA). Scan data files were saved as stereolithography (STL) files for the measurements. From the STL files, digital face models are created in the computer using Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). Various measurements were measured five times from the reference points in three axes (x, y, and z) using a digital Vernier caliper (VC) (Mitutoyo 150 mm Digital Caliper, Mitutoyo Co., Kanagawa, Japan), and the mean was calculated, which was used as the control. Measurements were measured on the digital face models of EP, EP+, IPX, and PM using Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). The descriptive statistics were done from SPSS version 20 (IBM Company, Chicago, USA). One-way ANOVA with post hoc using Scheffe was done to analyze the differences between the control and the scans (EP, EP+, IPX, and PM). The significance level was set at p = 0.05. EP+ showed the highest accuracy. EP showed medium accuracy and some lesser accuracy (accurate until 10 mm of length), but IPX and PM showed the least accuracy. EP+ showed accuracy in measuring the 2 mm of depth (diameter 6 mm). All other scanners (EP, IPX, and PM) showed less accuracy in measuring depth. Finally, the accuracy of an optical scan is dependent on the technology used by each scanner. It is recommended to use EP+ for face scanning.
Title: The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study
Description:
Face scanners promise wide applications in medicine and dentistry, including facial recognition, capturing facial emotions, facial cosmetic planning and surgery, and maxillofacial rehabilitation.
Higher accuracy improves the quality of the data recorded from the face scanner, which ultimately, will improve the outcome.
Although there are various face scanners available on the market, there is no evidence of a suitable face scanner for practical applications.
The aim of this in vitro study was to analyze the face scans obtained from four scanners; EinScan Pro (EP), EinScan Pro 2X Plus (EP+) (Shining 3D Tech.
Co.
, Ltd.
Hangzhou, China), iPhone X (IPX) (Apple Store, Cupertino, CA, USA), and Planmeca ProMax 3D Mid (PM) (Planmeca USA, Inc.
IL, USA), and to compare scans obtained from various scanners with the control (measured from Vernier caliper).
This should help to identify the appropriate scanner for face scanning.
A master face model was created and printed from polylactic acid using the resolution of 200 microns on x, y, and z axes and designed in Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA).
The face models were 3D scanned with four scanners, five times, according to the manufacturer’s recommendations; EinScan Pro (Shining 3D Tech.
Co.
, Ltd.
Hangzhou, China), EinScan Pro 2X Plus (Shining 3D Tech.
Co.
, Ltd.
Hangzhou, China) using Shining Software, iPhone X (Apple Store, Cupertino, CA, USA) using Bellus3D Face Application (Bellus3D, version 1.
6.
2, Bellus3D, Inc.
Campbell, CA, USA), and Planmeca ProMax 3D Mid (PM) (Planmeca USA, Inc.
IL, USA).
Scan data files were saved as stereolithography (STL) files for the measurements.
From the STL files, digital face models are created in the computer using Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA).
Various measurements were measured five times from the reference points in three axes (x, y, and z) using a digital Vernier caliper (VC) (Mitutoyo 150 mm Digital Caliper, Mitutoyo Co.
, Kanagawa, Japan), and the mean was calculated, which was used as the control.
Measurements were measured on the digital face models of EP, EP+, IPX, and PM using Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA).
The descriptive statistics were done from SPSS version 20 (IBM Company, Chicago, USA).
One-way ANOVA with post hoc using Scheffe was done to analyze the differences between the control and the scans (EP, EP+, IPX, and PM).
The significance level was set at p = 0.
05.
EP+ showed the highest accuracy.
EP showed medium accuracy and some lesser accuracy (accurate until 10 mm of length), but IPX and PM showed the least accuracy.
EP+ showed accuracy in measuring the 2 mm of depth (diameter 6 mm).
All other scanners (EP, IPX, and PM) showed less accuracy in measuring depth.
Finally, the accuracy of an optical scan is dependent on the technology used by each scanner.
It is recommended to use EP+ for face scanning.

Related Results

ACCURACY AND PRECISION OF SIX DIGITAL SCANNERS IN FULL ARCH MAXILLARY SCANS: AN IN VITRO COMPARATIVE STUDY
ACCURACY AND PRECISION OF SIX DIGITAL SCANNERS IN FULL ARCH MAXILLARY SCANS: AN IN VITRO COMPARATIVE STUDY
The objective of this study is to evaluate the accuracy and precision of full arch maxillary digital scans produced by six digital scanners. Materials and Methods: A standard model...
Access Denied
Access Denied
Introduction As social-distancing mandates in response to COVID-19 restricted in-person data collection methods such as participant observation and interviews, researchers turned t...
Comparative study of clinical indication-based DRLs with anatomical region-based DRLs in adult patients CT-scans in Yaounde - Cameroon.
Comparative study of clinical indication-based DRLs with anatomical region-based DRLs in adult patients CT-scans in Yaounde - Cameroon.
Background : CT-scan is the major source of population exposure in diagnostic x-rays radiology. DRLs is one of the main optimization tools, initially established by anatomical regi...
Comparative Evaluation of Digital Accuracy Among Three Intraoral Scanners for Posterior Implant and Tooth Scans
Comparative Evaluation of Digital Accuracy Among Three Intraoral Scanners for Posterior Implant and Tooth Scans
Aim: This study evaluates the digital accuracy of posterior implant scans and contralateral molar tooth scans obtained with three different intraoral scanners. Materials and Method...
Comparative evaluation of the accuracy of the dental arch display using modern intraoral three-dimensional scanners
Comparative evaluation of the accuracy of the dental arch display using modern intraoral three-dimensional scanners
BACKGROUND: At present, modern dentists used dental intraoral three-dimensional (3D) scanners routinely in their daily work. Obtaining an optical 3D image of the teeth and dentitio...
The influence of micro influencers and digital marketing on product purchasing decisions at tiktok shop in bengkulu city
The influence of micro influencers and digital marketing on product purchasing decisions at tiktok shop in bengkulu city
THE INFLUENCE OF MICRO-INFLUENCERS AND DIGITAL MARKETING ON PURCHASE DECISIONS OF TIKTOK SHOP CUSTOMERS IN BENGKULU CITY Andhes Tiani Putri, Meylaty F   12Faculty Of Economic E...
Comparison of Accuracy of Current Ten Intraoral Scanners
Comparison of Accuracy of Current Ten Intraoral Scanners
There have been various developments in intraoral 3D scanning technology. This study is aimed at investigating the accuracy of 10 scanners developed from 2015 to 2020. A maxillary ...

Back to Top