Comparative study of the temperature-sensitive materials for D-shaped optical fiber-based temperature sensor

View through CrossRef
Optical fiber-based surface plasmon resonance (SPR) sensors provide exceptional sensitivity, a compact design, and the capability for remote monitoring, making them ideal for advanced detection systems. Temperature-responsive liquids such as chloroform, chloroform-ethanol mixtures, and ethanol-glycerol mixtures hold significant potential in biomedical optical fiber sensors due to their ability to react to temperature changes. These liquids exhibit significant refractive index (n) changes with temperature (T), quantified by the thermo-optic coefficient (dn/dT), enabling precise, non-invasive, and real-time temperature monitoring. This study explores the incorporation of different temperature-sensitive analytes into a D-shaped double-channel optical fiber for a wide range of temperature sensing in a single sensing platform. The double-channel sensor employs gold as the plasmonic material and channel 1 is filled with a fluid having a constant refractive index of 1.33, while channel 2 is filled with temperature-sensitive liquids. The refractive index of channel 2 is modeled as the base refractive index adjusted by the product of dn/dT and the temperature difference relative to a reference. Sensitivity analyses span temperatures from 283.15 °K (10°C) to 343.15 °K (70°C), addressing biomedical and industrial sensing applications. The findings indicate that chloroform and mixtures of chloroform with ethanol demonstrate exceptional sensitivity as temperature-sensitive analytes. Chloroform achieves a maximum refractive index sensitivity of 429.82 nm/RIU in the RI range of 1.33–1.45 and temperature sensitivity of 5 nm/°K. A 50:50 chloroform-ethanol mixture enhances refractive index sensitivity to 714.28 nm/RIU in the range of 1.33–1.40 while maintaining 5 nm/°K temperature sensitivity. In contrast, a 34:66 ethanol-glycerol mixture exhibits a refractive index sensitivity of -453.72 nm/RIU in the range of refractive index 1.33–1.44 and temperature sensitivity of -5 nm/°K. These findings establish chloroform and its mixtures as highly promising candidates for efficient optical temperature sensing in both biomedical and industrial applications.
Title: Comparative study of the temperature-sensitive materials for D-shaped optical fiber-based temperature sensor
Description:
Optical fiber-based surface plasmon resonance (SPR) sensors provide exceptional sensitivity, a compact design, and the capability for remote monitoring, making them ideal for advanced detection systems.
Temperature-responsive liquids such as chloroform, chloroform-ethanol mixtures, and ethanol-glycerol mixtures hold significant potential in biomedical optical fiber sensors due to their ability to react to temperature changes.
These liquids exhibit significant refractive index (n) changes with temperature (T), quantified by the thermo-optic coefficient (dn/dT), enabling precise, non-invasive, and real-time temperature monitoring.
This study explores the incorporation of different temperature-sensitive analytes into a D-shaped double-channel optical fiber for a wide range of temperature sensing in a single sensing platform.
The double-channel sensor employs gold as the plasmonic material and channel 1 is filled with a fluid having a constant refractive index of 1.
33, while channel 2 is filled with temperature-sensitive liquids.
The refractive index of channel 2 is modeled as the base refractive index adjusted by the product of dn/dT and the temperature difference relative to a reference.
Sensitivity analyses span temperatures from 283.
15 °K (10°C) to 343.
15 °K (70°C), addressing biomedical and industrial sensing applications.
The findings indicate that chloroform and mixtures of chloroform with ethanol demonstrate exceptional sensitivity as temperature-sensitive analytes.
Chloroform achieves a maximum refractive index sensitivity of 429.
82 nm/RIU in the RI range of 1.
33–1.
45 and temperature sensitivity of 5 nm/°K.
A 50:50 chloroform-ethanol mixture enhances refractive index sensitivity to 714.
28 nm/RIU in the range of 1.
33–1.
40 while maintaining 5 nm/°K temperature sensitivity.
In contrast, a 34:66 ethanol-glycerol mixture exhibits a refractive index sensitivity of -453.
72 nm/RIU in the range of refractive index 1.
33–1.
44 and temperature sensitivity of -5 nm/°K.
These findings establish chloroform and its mixtures as highly promising candidates for efficient optical temperature sensing in both biomedical and industrial applications.

Related Results

Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
A preliminary study on wellbore flow interpretation of fiber optic vibration signals based on K-means clustering algorithm
A preliminary study on wellbore flow interpretation of fiber optic vibration signals based on K-means clustering algorithm
AbstractThe wellbore flow analysis of optical fiber vibration signal depends on distributed optical fiber logging. Distributed optical fiber logging technology identifies the fluid...
Enhancing Landslide Early Warning: Advances in Fiber Optic Sensor Sensitivity
Enhancing Landslide Early Warning: Advances in Fiber Optic Sensor Sensitivity
Fiber optic sensors offer a high-performance alternative because they provide a low-cost solution, resistance to electromagnetic interference, multiplexing capabilities, and high i...
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
The continuous improvements of optical design tools and manufacturing technologies of free-form optical elements, allow the creation of new complex-shaped lenses that improve the p...
Optical Reservoir Instrumentation System
Optical Reservoir Instrumentation System
I. Introduction Fiber optic sensors are opening up new capabilities for sensing a wide range of parameters, such as pressure, temperature, vibration, flow, acoust...
3D Printed Flexible Plastic Diaphragm for Optical Pressure Sensor Application
3D Printed Flexible Plastic Diaphragm for Optical Pressure Sensor Application
Introduction Due to ongoing growth in automotive market, and also in order to respond the rising customers’ demands on driving the safe, comfort and ...
Impedance and plasmonic based MEMS sensors for chemical and biological applications
Impedance and plasmonic based MEMS sensors for chemical and biological applications
[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI-COLUMBIA AT REQUEST OF AUTHOR.] The first project is implementing a biosensor for simultaneous detection of Salmonella serogroups. ...

Back to Top