Javascript must be enabled to continue!
Pediatric normative Retinal nerve fiber layer thickness in south Indian population
View through CrossRef
To study the retinal nerve fiber layer (RNFL) thickness in pediatric age group and its correlation with age, gender, refractive error and axial length Prospective observational study of 200 eyes of 100 children aged between 5-18 years presenting to the ophthalmic department. All children underwent detailed ophthalmic evaluation and SD OCT examination for RNFL thickness, Standard RNFL assessment protocol was used. Mean RNFL thickness in micrometers along the whole circle circumference, four quadrants, 12’o clock hours were obtained. RNFL measurements included average/full circle thickness — RNFL-FC (360ºmeasure), temporal quadrant thickness, RNFL-T, superior quadrant thickness, RNFL-S, nasal quadrant thickness, RNFL-N, inferior quadrant thickness, RNFL-I. Mean age was 13.3 ± 2.4 years. The refractive error in spherical equivalent was -0.28 ± 0.91 dioptre (SE). The mean axial length was 23.1 ± 0.7mm. The mean global RNFL thickness (RNFL-FC) was 97.0 ± 8.8mm (range 79.4 -114.6). RNFL thickness was maximum in the inferior quadrant (RNFL-I) 126 ± 13.7mm followed in order by superior (RNFL-S) 126 ± 16.3mm, nasal (RNFL-N) 70.5 ± 12.3mm and temporal (RNFL-T) 63.4 ± 9.2mm, in both the sexes. For every increase in one diopter of spherical equivalent of refractive error the mean RNFL increased by 3.77 microns and there was a reduction in mean RNFL thickness by 4.86 micron for every 1mm increase in axial length. RNFL varied minimally with gender. Positive correlation was seen with refractive error while inverse or negative correlation was seen with axial length and age. RNFL measurements could serve as reference for further studies on pediatric glaucoma or other optic nerve head pathologies.
IP Innovative Publication Pvt Ltd
Title: Pediatric normative Retinal nerve fiber layer thickness in south Indian population
Description:
To study the retinal nerve fiber layer (RNFL) thickness in pediatric age group and its correlation with age, gender, refractive error and axial length Prospective observational study of 200 eyes of 100 children aged between 5-18 years presenting to the ophthalmic department.
All children underwent detailed ophthalmic evaluation and SD OCT examination for RNFL thickness, Standard RNFL assessment protocol was used.
Mean RNFL thickness in micrometers along the whole circle circumference, four quadrants, 12’o clock hours were obtained.
RNFL measurements included average/full circle thickness — RNFL-FC (360ºmeasure), temporal quadrant thickness, RNFL-T, superior quadrant thickness, RNFL-S, nasal quadrant thickness, RNFL-N, inferior quadrant thickness, RNFL-I.
Mean age was 13.
3 ± 2.
4 years.
The refractive error in spherical equivalent was -0.
28 ± 0.
91 dioptre (SE).
The mean axial length was 23.
1 ± 0.
7mm.
The mean global RNFL thickness (RNFL-FC) was 97.
0 ± 8.
8mm (range 79.
4 -114.
6).
RNFL thickness was maximum in the inferior quadrant (RNFL-I) 126 ± 13.
7mm followed in order by superior (RNFL-S) 126 ± 16.
3mm, nasal (RNFL-N) 70.
5 ± 12.
3mm and temporal (RNFL-T) 63.
4 ± 9.
2mm, in both the sexes.
For every increase in one diopter of spherical equivalent of refractive error the mean RNFL increased by 3.
77 microns and there was a reduction in mean RNFL thickness by 4.
86 micron for every 1mm increase in axial length.
RNFL varied minimally with gender.
Positive correlation was seen with refractive error while inverse or negative correlation was seen with axial length and age.
RNFL measurements could serve as reference for further studies on pediatric glaucoma or other optic nerve head pathologies.
Related Results
Retinal Oximetry
Retinal Oximetry
Abstract.Purpose:Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract
Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
BACKGROUND:
The geographic relationship between pediatric anesthesiologists and the pediatric population has potentially important clinical and policy implications. In ...
Assessment of Effects of Pan-Retinal Photocoagulation on Retinal Nerve Fibre Layer By Optical Coherence Tomography
Assessment of Effects of Pan-Retinal Photocoagulation on Retinal Nerve Fibre Layer By Optical Coherence Tomography
Objective: To assess the Retinal Nerve Fiber Layer by Optical Coherence Tomography in patients treated with pan-retinal photocoagulation at one-month and three-month post-treatment...
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
BACKGROUND:
A workforce analysis was conducted to predict whether the projected future supply of pediatric anesthesiologists is balanced with the requirements o...
Phrenic Nerve Block for Management of Post-Thoracic Outlet Decompression Cough: A Case Report and Literature Review
Phrenic Nerve Block for Management of Post-Thoracic Outlet Decompression Cough: A Case Report and Literature Review
Abstract
Introduction
Thoracic outlet syndrome is a group of disorders arising from compressive forces on the neurovascular bundle in that region due to different etiologies. This...
Anatomical and functional correlates of cystic macular edema in retinitis pigmentosa
Anatomical and functional correlates of cystic macular edema in retinitis pigmentosa
Cystoid macular edema (CME) is a major cause of central visual deterioration in retinitis pigmentosa. The exact reason for CME and its prognostic significance in this patient popul...
Retinal oximetry in patients with ischaemic retinal diseases
Retinal oximetry in patients with ischaemic retinal diseases
AbstractThe retinal oximeter is a new tool for non‐invasive measurement of retinal oxygen saturation in humans. Several studies have investigated the associations between retinal o...

