The use of a low-cost monitoring dataset for sewer model autocalibration

View through CrossRef
The management of urban wastewater systems and the associated modelling of these systems has become indispensable in today's world. In order for these models to represent reality as accurately as possible, a reliable calibration is essential. Water level data is used as a standard, but due to expensive sensors and harsh conditions in the sewer, data can only be collected at a few key points of the system. One novel solution, that has experienced an upswing in recent years, is collecting data using low-cost temperature sensors. Two sensors are needed; one is placed in the stream; the other is placed at the crest of the weir. In the case of dry weather, the sensor measures the air phase, whereas, in the case of Combined Sewer Overflow (CSO), the discharged storm and wastewater is measured. The start and end of a CSO event can be determined via the merging of measured temperature values in both points of the overflow structure. Due to this method, the duration of CSO events in a sewer system can be detected.In this work, the potential benefits of this novel method for model calibration are assessed. Therefore, autocalibration runs with water level data and fictional temperature data were carried out via OSTRICH for a SWMM model located in Berlin. Furthermore, calibration runs with a different number of measuring sites were performed, to evaluate the amount of necessary measuring sites for a reliable calibration. In order to be able to compare the different approaches, a calibration period of 19 events was first required for the respective datatype. Next, a validation period which consisted of 18 events was carried out and evaluated by the R² of three water level measuring sites for both approaches to ensure comparability. It was revealed that the calibration with duration data based on temperature sensors was able to achieve results as good as the conventional approach using water level data. Due to low spatial distribution of the measuring sites in the model, it could not be finally answered if more measuring sites would yield to even better results. However, already with one measuring site, promising calibration outcomes could be achieved and thus, offers an alternative for water utilities and practitioners.
Title: The use of a low-cost monitoring dataset for sewer model autocalibration
Description:
The management of urban wastewater systems and the associated modelling of these systems has become indispensable in today's world.
In order for these models to represent reality as accurately as possible, a reliable calibration is essential.
Water level data is used as a standard, but due to expensive sensors and harsh conditions in the sewer, data can only be collected at a few key points of the system.
One novel solution, that has experienced an upswing in recent years, is collecting data using low-cost temperature sensors.
Two sensors are needed; one is placed in the stream; the other is placed at the crest of the weir.
In the case of dry weather, the sensor measures the air phase, whereas, in the case of Combined Sewer Overflow (CSO), the discharged storm and wastewater is measured.
The start and end of a CSO event can be determined via the merging of measured temperature values in both points of the overflow structure.
Due to this method, the duration of CSO events in a sewer system can be detected.
In this work, the potential benefits of this novel method for model calibration are assessed.
Therefore, autocalibration runs with water level data and fictional temperature data were carried out via OSTRICH for a SWMM model located in Berlin.
Furthermore, calibration runs with a different number of measuring sites were performed, to evaluate the amount of necessary measuring sites for a reliable calibration.
In order to be able to compare the different approaches, a calibration period of 19 events was first required for the respective datatype.
Next, a validation period which consisted of 18 events was carried out and evaluated by the R² of three water level measuring sites for both approaches to ensure comparability.
It was revealed that the calibration with duration data based on temperature sensors was able to achieve results as good as the conventional approach using water level data.
Due to low spatial distribution of the measuring sites in the model, it could not be finally answered if more measuring sites would yield to even better results.
However, already with one measuring site, promising calibration outcomes could be achieved and thus, offers an alternative for water utilities and practitioners.

Related Results

Economical Design of Sewer Line in Flat Terrain: A Case Study of Rajapur Sewerage System
Economical Design of Sewer Line in Flat Terrain: A Case Study of Rajapur Sewerage System
Design of sewer line in flat terrain is a great challenge due to high excavation depth involved in laying a sewer line required for maintaining minimum velocity, slope and clear co...
In situ concrete sewer performance: comparison of Portland cement, calcium sulfoaluminate cement, and calcium aluminate cement
In situ concrete sewer performance: comparison of Portland cement, calcium sulfoaluminate cement, and calcium aluminate cement
Abstract This paper provides a better understanding of the performance of calcium sulfoaluminate cement (CSA) in comparison with calcium aluminate cement (CAC) and Portland...
Satellite-based rainfall datasets and autocalibration techniques’ effects on SWAT+ flow prediction
Satellite-based rainfall datasets and autocalibration techniques’ effects on SWAT+ flow prediction
Accurate flow prediction is a primary goal of hydrological modeling studies, which can be affected by the use of varying rainfall datasets, autocalibration methods, and performance...
CONDITION PREDICTION OF SANITARY SEWERAGE PIPELINE SYSTEMS USING MULTINOMIAL LOGISTIC REGRESSION
CONDITION PREDICTION OF SANITARY SEWERAGE PIPELINE SYSTEMS USING MULTINOMIAL LOGISTIC REGRESSION
It is important for the sanitary sewerage pipeline system to be in a good condition for providing safe conveyance of the wastewater from households, businesses, and industries to t...
EFFICIENCY OF CLEANING SEWER PIPES
EFFICIENCY OF CLEANING SEWER PIPES
As a result of human activity, waste and products that are not suitable for further use are formed, which are mainly disposed of by draining them through networks of urban sewer pi...
Localisation Task in Sewer Networks
Localisation Task in Sewer Networks
Paper deals with the inverse / localisation task in sewer networks. An inverse problem is defined as the process of determining the causal factors from a set of observations. Apply...
Vulnerability Assessment of Sewer Networks
Vulnerability Assessment of Sewer Networks
Abstract Urban storm water management faces significant challenges due to climate change, especially in cities with aging combined sewer systems. Many of these networks, wh...

Back to Top