Javascript must be enabled to continue!
Electrical conductivity anomalies study
View through CrossRef
Anomalous currents in a well-conducting body arise due to local electromagnetic induction inside the anomalous body, as well as due to conductive redistribution (and concentration) of currents induced in the host medium on a large territory equal to the external source size. The local induction generates the so-called anomaly of geomagnetic variations of the magnetic or inductive type. Its characteristic property is that the secondary anomalous field cannot be greater than the primary normal field of geomagnetic variations. However, in some places on the earth’s surface, the normalized anomalous fields are greater than 1. Analytical solution of the EM induction problem for circular cylinder yields the physical explanation of two types of anomalous geomagnetic fields. The first term (proportional to the normal electric field E0) describes the conductive anomaly type, the second term (proportional to the normal magnetic field B0) describes the inductive anomaly type. The conductive type usually is much greater than the inductive one. The normalized anomalous field of the conductive type is not limited to 1 or any other value. It is proportional to two functions: V(T) — the non-decreasing function of the period T (0≤V≤1, V=1 corresponds to DC) which describes the degree of filling of the conductor by anomalous currents (result of the skin effect inside the anomaly) and the normal impedance of inclosing cross-section — the decreasing function of the period. Product of these functions has a maximum at some period T0. The position T0 is closely related to the total lengthwise conductance G[S×m] of the anomalous body, that is, the scale of the anomaly. On the period T0, the anomalous fields and the induction vector become real C=Cu and the imaginary induction vector Cv passes through zero changing sign. Thus, the spectral properties of the geomagnetic response functions were studied for two-dimensional anomalies with a generalization to three-dimensional conductors with varying cross-section. 18 crustal electrical conductivity anomalies were considered and their integral lengthwise conductance G was obtained. At all anomalies, the G values turn out to be in a relatively narrow range G=(1—8)·108 S∙m; this has geophysical significance.
Institute of Geophysics of the National Academy of Sciences of Ukraine by S.I. Subbotin name
Title: Electrical conductivity anomalies study
Description:
Anomalous currents in a well-conducting body arise due to local electromagnetic induction inside the anomalous body, as well as due to conductive redistribution (and concentration) of currents induced in the host medium on a large territory equal to the external source size.
The local induction generates the so-called anomaly of geomagnetic variations of the magnetic or inductive type.
Its characteristic property is that the secondary anomalous field cannot be greater than the primary normal field of geomagnetic variations.
However, in some places on the earth’s surface, the normalized anomalous fields are greater than 1.
Analytical solution of the EM induction problem for circular cylinder yields the physical explanation of two types of anomalous geomagnetic fields.
The first term (proportional to the normal electric field E0) describes the conductive anomaly type, the second term (proportional to the normal magnetic field B0) describes the inductive anomaly type.
The conductive type usually is much greater than the inductive one.
The normalized anomalous field of the conductive type is not limited to 1 or any other value.
It is proportional to two functions: V(T) — the non-decreasing function of the period T (0≤V≤1, V=1 corresponds to DC) which describes the degree of filling of the conductor by anomalous currents (result of the skin effect inside the anomaly) and the normal impedance of inclosing cross-section — the decreasing function of the period.
Product of these functions has a maximum at some period T0.
The position T0 is closely related to the total lengthwise conductance G[S×m] of the anomalous body, that is, the scale of the anomaly.
On the period T0, the anomalous fields and the induction vector become real C=Cu and the imaginary induction vector Cv passes through zero changing sign.
Thus, the spectral properties of the geomagnetic response functions were studied for two-dimensional anomalies with a generalization to three-dimensional conductors with varying cross-section.
18 crustal electrical conductivity anomalies were considered and their integral lengthwise conductance G was obtained.
At all anomalies, the G values turn out to be in a relatively narrow range G=(1—8)·108 S∙m; this has geophysical significance.
Related Results
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Abstract
A cervical rib (CR), also known as a supernumerary or extra rib, is an additional rib that forms above the first rib, resulting from the overgrowth of the transverse proce...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
A NOVEL MONTE CARLO SIMULATION ON THE ELECTRICAL CONDUCTIVITY OF FRACTAL POROUS MEDIA
A NOVEL MONTE CARLO SIMULATION ON THE ELECTRICAL CONDUCTIVITY OF FRACTAL POROUS MEDIA
The electrical conductivity of porous media has received more and more attention in the fields of geophysics and petroleum engineering. In this study, a Monte Carlo method, combine...
A Semianalytical Solution of a Vertical Fractured Well With Varying Conductivity Under Non-Darcy-Flow Condition
A Semianalytical Solution of a Vertical Fractured Well With Varying Conductivity Under Non-Darcy-Flow Condition
Summary
Fracture distributions (simple or complex fractures), fracture-conductivity heterogeneity (uniform or varying conductivity along the fracture), and flow regi...
A Method to Improve Computational Efficiency of Productivity Evaluation with Rectangular Coalbed Methane Reservoir
A Method to Improve Computational Efficiency of Productivity Evaluation with Rectangular Coalbed Methane Reservoir
Computational efficiency is the key factor to be considered in the productivity evaluation of rectangular coalbed methane reservoir. There are three main factors affecting the calc...
Electrical conductivity measurement of CaO-Al2O3-CaF2 slags by van der Pauw-Ohta Method
Electrical conductivity measurement of CaO-Al2O3-CaF2 slags by van der Pauw-Ohta Method
Electro slag remelting (ESR) is one of the methods used to produce high-cleanliness steel. In the ESR method, the product steel electrode is immersed in flux, and the electrode is ...
Calculational Clarification of the Reduction Factors Against Ionic Conductivity of Solid Electrolyte in All-Solid-State Battery
Calculational Clarification of the Reduction Factors Against Ionic Conductivity of Solid Electrolyte in All-Solid-State Battery
All-solid-state batteries are desired to be used especially for electric vehicles due to the expected features for rapid charging, safety, and unnecessity of battery cooling system...
CONDUCTIVITY OF SOLID SOLUTIONS Pb0,86 xSmxSn1,14F4+x
CONDUCTIVITY OF SOLID SOLUTIONS Pb0,86 xSmxSn1,14F4+x
In the PbF2 – SmF3 – SnF2 system, heterovalent substitution solid solutions Pb0.86-xSmxSn1,14F4+x (0 < x ≤ 0.15) with the structure β-PbSnF4 are formed. The unit cell paramete...

