Javascript must be enabled to continue!
AO distractor and manual traction reduction techniques repair in distal tibial fractures: a comparative study
View through CrossRef
Abstract
Background: Minimally invasive plate osteosynthesis (MIPO) via percutaneous plate placement on the distal medial tibia can be performed with minimizes soft tissue injury and produces good clinical results. However, the difficulty with MIPO lies in how to achieve satisfactory fracture reduction and maintain that reduction via indirect reduction techniques to facilitate internal fixation.The purpose of this study was to compare the effects of AO distractor and manual traction reduction techniques combined with MIPO in the treatment of distal tibia fractures. Methods: Between January 2013 and December 2019, 58 patients with a distal tibia fracture were treated using MIPO. Patients were divided into two groups according to the indirect reduction method that was used: 26 patients were reduced with manual traction(group M), and 32 were reduced with an AO distractor (group A).Time until union and clinical outcomes including AOFAS ankle-rating score and ankle range of ankle motion at final follow-up were compared. Mean operative time, incision length, blood loss and postoperative complications were recorded via chart review. Radiographic results at final follow-up were assessed for tibial angulation and shortening by a blinded reader.Results: Mean operative time, incision length, and blood loss in group A were significantly lower than in group M(p=0.019, 0.018 and0.016, respectively).Radiographic evidence of bony union was seen in all cases, and mean time until union was equivalent between the two groups (p=0.384).Skin irritation was noted in one case(3.1%) in group A and three cases(11.5%)in group M, but the symptoms were not severe and the plate was removed after bony union. There was no statistically significant difference in postoperative complications between the two groups(p=0.461). Mean AOFAS score and range of ankle motion were equivalent between the two groups, as were varus deformity, valgus deformity, anterior angulation and posterior angulation. No patients had gross angular deformity. Mean tibial shortening was not significantly different between the two groups, and no patients had tibial shortening >10 mm.Conclusion: Both an AO distractor and manual traction reduction techniques prior to MIPO in the treatment of distal tibial fractures permit a high fracture healing rate and satisfying functional outcomes with few wound healing complications. An AO distractor is an excellent indirect reduction method that may improve operative efficiency and reduce the risk of soft tissue injury.
Title: AO distractor and manual traction reduction techniques repair in distal tibial fractures: a comparative study
Description:
Abstract
Background: Minimally invasive plate osteosynthesis (MIPO) via percutaneous plate placement on the distal medial tibia can be performed with minimizes soft tissue injury and produces good clinical results.
However, the difficulty with MIPO lies in how to achieve satisfactory fracture reduction and maintain that reduction via indirect reduction techniques to facilitate internal fixation.
The purpose of this study was to compare the effects of AO distractor and manual traction reduction techniques combined with MIPO in the treatment of distal tibia fractures.
Methods: Between January 2013 and December 2019, 58 patients with a distal tibia fracture were treated using MIPO.
Patients were divided into two groups according to the indirect reduction method that was used: 26 patients were reduced with manual traction(group M), and 32 were reduced with an AO distractor (group A).
Time until union and clinical outcomes including AOFAS ankle-rating score and ankle range of ankle motion at final follow-up were compared.
Mean operative time, incision length, blood loss and postoperative complications were recorded via chart review.
Radiographic results at final follow-up were assessed for tibial angulation and shortening by a blinded reader.
Results: Mean operative time, incision length, and blood loss in group A were significantly lower than in group M(p=0.
019, 0.
018 and0.
016, respectively).
Radiographic evidence of bony union was seen in all cases, and mean time until union was equivalent between the two groups (p=0.
384).
Skin irritation was noted in one case(3.
1%) in group A and three cases(11.
5%)in group M, but the symptoms were not severe and the plate was removed after bony union.
There was no statistically significant difference in postoperative complications between the two groups(p=0.
461).
Mean AOFAS score and range of ankle motion were equivalent between the two groups, as were varus deformity, valgus deformity, anterior angulation and posterior angulation.
No patients had gross angular deformity.
Mean tibial shortening was not significantly different between the two groups, and no patients had tibial shortening >10 mm.
Conclusion: Both an AO distractor and manual traction reduction techniques prior to MIPO in the treatment of distal tibial fractures permit a high fracture healing rate and satisfying functional outcomes with few wound healing complications.
An AO distractor is an excellent indirect reduction method that may improve operative efficiency and reduce the risk of soft tissue injury.
Related Results
Neural Evidence for Feature-based Distractor Inhibition
Neural Evidence for Feature-based Distractor Inhibition
Interference from a salient distractor is typically reduced when the appearance of the distractor follows either spatial or feature-based regularities. While there is a growing bod...
Proximal Tibial Epiphysiodesis in a Growing Dog
Proximal Tibial Epiphysiodesis in a Growing Dog
Background: It is believed that the inclined tibial plateau angle to be a major cause of cranial cruciate ligament (CCL) rupture, and the treatment of this disease is the tibial p...
Concomitant Medial Meniscal Root Repair with Extrusion Repair (Centralization Technique)
Concomitant Medial Meniscal Root Repair with Extrusion Repair (Centralization Technique)
Background:
Meniscal extrusion is a phenomenon in which a degenerative posterior horn tear, radial tear, or root tear results in displacement of the body of the meniscu...
FRACTURES OF THE TIBIAL COLUMN (FCT), FRACTURES OF THE TIBIAL EMINENCE OR INTERCONDYLAR EMINENCE
FRACTURES OF THE TIBIAL COLUMN (FCT), FRACTURES OF THE TIBIAL EMINENCE OR INTERCONDYLAR EMINENCE
Introduction: Tibial spine fractures (TSCF), also called tibial eminence or intercondylar eminence fractures, are defined as bony or chondral avulsions of the tibial plateau at the...
Clinical and Functional Outcome of Distal Tibial Fractures Treated with Minimally Invasive Percutaneous Plate Osteosynthesis Technique using Anatomical Distal Tibial Plate: A Case Series
Clinical and Functional Outcome of Distal Tibial Fractures Treated with Minimally Invasive Percutaneous Plate Osteosynthesis Technique using Anatomical Distal Tibial Plate: A Case Series
Introduction: Distal tibial fractures are difficult to manage due to their complex anatomy, subcutaneous location, and poor vascularity. Conventional open plating often causes soft...
A Rare Case of Combined Tibial Plateau Fracture with Tibial Tuberosity Avulsion Injury: Case Report Showry Abraham Salikity , Kalyan Deepak Sreenvas , Muni Srikanth Iytha , Vineet Thomas Abraham ,
A Rare Case of Combined Tibial Plateau Fracture with Tibial Tuberosity Avulsion Injury: Case Report Showry Abraham Salikity , Kalyan Deepak Sreenvas , Muni Srikanth Iytha , Vineet Thomas Abraham ,
Introduction: Avulsion fracture of the tibial tuberosity is a rare orthopedic injury, predominantly affecting adolescents but seldom seen in the adult population. Lateral tibial pl...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...

