Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

AO distractor and manual traction reduction techniques repair in distal tibial fractures: a comparative study

View through CrossRef
Abstract Background: Minimally invasive plate osteosynthesis (MIPO) via percutaneous plate placement on the distal medial tibia can be performed with minimizes soft tissue injury and produces good clinical results. However, the difficulty with MIPO lies in how to achieve satisfactory fracture reduction and maintain that reduction via indirect reduction techniques to facilitate internal fixation.The purpose of this study was to compare the effects of AO distractor and manual traction reduction techniques combined with MIPO in the treatment of distal tibia fractures. Methods: Between January 2013 and December 2019, 58 patients with a distal tibia fracture were treated using MIPO. Patients were divided into two groups according to the indirect reduction method that was used: 26 patients were reduced with manual traction(group M), and 32 were reduced with an AO distractor (group A).Time until union and clinical outcomes including AOFAS ankle-rating score and ankle range of ankle motion at final follow-up were compared. Mean operative time, incision length, blood loss and postoperative complications were recorded via chart review. Radiographic results at final follow-up were assessed for tibial angulation and shortening by a blinded reader.Results: Mean operative time, incision length, and blood loss in group A were significantly lower than in group M(p=0.019, 0.018 and0.016, respectively).Radiographic evidence of bony union was seen in all cases, and mean time until union was equivalent between the two groups (p=0.384).Skin irritation was noted in one case(3.1%) in group A and three cases(11.5%)in group M, but the symptoms were not severe and the plate was removed after bony union. There was no statistically significant difference in postoperative complications between the two groups(p=0.461). Mean AOFAS score and range of ankle motion were equivalent between the two groups, as were varus deformity, valgus deformity, anterior angulation and posterior angulation. No patients had gross angular deformity. Mean tibial shortening was not significantly different between the two groups, and no patients had tibial shortening >10 mm.Conclusion: Both an AO distractor and manual traction reduction techniques prior to MIPO in the treatment of distal tibial fractures permit a high fracture healing rate and satisfying functional outcomes with few wound healing complications. An AO distractor is an excellent indirect reduction method that may improve operative efficiency and reduce the risk of soft tissue injury.
Title: AO distractor and manual traction reduction techniques repair in distal tibial fractures: a comparative study
Description:
Abstract Background: Minimally invasive plate osteosynthesis (MIPO) via percutaneous plate placement on the distal medial tibia can be performed with minimizes soft tissue injury and produces good clinical results.
However, the difficulty with MIPO lies in how to achieve satisfactory fracture reduction and maintain that reduction via indirect reduction techniques to facilitate internal fixation.
The purpose of this study was to compare the effects of AO distractor and manual traction reduction techniques combined with MIPO in the treatment of distal tibia fractures.
Methods: Between January 2013 and December 2019, 58 patients with a distal tibia fracture were treated using MIPO.
Patients were divided into two groups according to the indirect reduction method that was used: 26 patients were reduced with manual traction(group M), and 32 were reduced with an AO distractor (group A).
Time until union and clinical outcomes including AOFAS ankle-rating score and ankle range of ankle motion at final follow-up were compared.
Mean operative time, incision length, blood loss and postoperative complications were recorded via chart review.
Radiographic results at final follow-up were assessed for tibial angulation and shortening by a blinded reader.
Results: Mean operative time, incision length, and blood loss in group A were significantly lower than in group M(p=0.
019, 0.
018 and0.
016, respectively).
Radiographic evidence of bony union was seen in all cases, and mean time until union was equivalent between the two groups (p=0.
384).
Skin irritation was noted in one case(3.
1%) in group A and three cases(11.
5%)in group M, but the symptoms were not severe and the plate was removed after bony union.
There was no statistically significant difference in postoperative complications between the two groups(p=0.
461).
Mean AOFAS score and range of ankle motion were equivalent between the two groups, as were varus deformity, valgus deformity, anterior angulation and posterior angulation.
No patients had gross angular deformity.
Mean tibial shortening was not significantly different between the two groups, and no patients had tibial shortening >10 mm.
Conclusion: Both an AO distractor and manual traction reduction techniques prior to MIPO in the treatment of distal tibial fractures permit a high fracture healing rate and satisfying functional outcomes with few wound healing complications.
An AO distractor is an excellent indirect reduction method that may improve operative efficiency and reduce the risk of soft tissue injury.

Related Results

Neural Evidence for Feature-based Distractor Inhibition
Neural Evidence for Feature-based Distractor Inhibition
Interference from a salient distractor is typically reduced when the appearance of the distractor follows either spatial or feature-based regularities. While there is a growing bod...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
FRACTURES OF THE TIBIAL COLUMN (FCT), FRACTURES OF THE TIBIAL EMINENCE OR INTERCONDYLAR EMINENCE
FRACTURES OF THE TIBIAL COLUMN (FCT), FRACTURES OF THE TIBIAL EMINENCE OR INTERCONDYLAR EMINENCE
Introduction: Tibial spine fractures (TSCF), also called tibial eminence or intercondylar eminence fractures, are defined as bony or chondral avulsions of the tibial plateau at the...
Effect of cervical suspensory traction in the treatment of severe cervical kyphotic deformity
Effect of cervical suspensory traction in the treatment of severe cervical kyphotic deformity
ObjectiveThis study aimed to investigate a new noninvasive traction method on the treatment of severe cervical kyphotic deformity.MethodsThe clinical data of patients with severe c...
Learned oculomotor avoidance during strong target guidance
Learned oculomotor avoidance during strong target guidance
Visual attention is guided toward behaviorally-relevant objects by target ‘templates’ stored in visual memory. Visual attention also is guided away from nontarget distractors by le...
Dynamic Parallel Traction's Impact on Femoral Neck Fracture Biomechanics: A 3D Finite Element Study
Dynamic Parallel Traction's Impact on Femoral Neck Fracture Biomechanics: A 3D Finite Element Study
Abstract Objective: This study aims to investigate the impact of dynamic parallel traction on the biomechanical characteristics of femoral neck fractures, with the goal of ...
TIBIAL DIAPHYSEAL FRACTURE, PANORAMIC REVISION
TIBIAL DIAPHYSEAL FRACTURE, PANORAMIC REVISION
Introduction: Tibial fractures are quite common injuries. Since the tibia has a subcutaneous location, it is more likely to show exposed fractures. Exposed fractures of the tibial ...

Back to Top