Abstract 13298: Density, Coverage and Usage of Automated External Defibrillators in Out-of-Hospital Cardiac Arrest Across Europe
View through CrossRef
Introduction:
Though deployment of Automated External Defibrillators (AEDs) is increasing rapidly, AEDs are often deployed in an un-strategic manner. Consequently, little is known about the association between AED density, AED coverage of out-of-hospital cardiac arrest (OHCA), and bystander defibrillation across different countries. This study aimed to investigate the differences in AED densities (AEDS/100,000 inhabitants/1,000 km2), the AED coverage of OHCAs, and bystander defibrillation across Europe.
Hypothesis:
AED density is directly associated with degree of bystander defibrillation across Europe.
Methods:
The study is a European Sudden Cardiac Arrest network towards Prevention, Education, New Effective Treatment (ESCAPE-NET) project. We included data from Ticino (Switzerland), Lombardy (Italy), and The Capital Region (Denmark) from 2019, covering over 3.7 million inhabitants. AED accessibility was defined as the AED being accessible 24/7 or not and AED coverage was defined as the OHCA being covered by an AED within 100, 250 and 500 meters. AED coverages were calculated the same way by all participants using a free software program (QGIS).
Results:
AED densities were: 87.3 for Ticino, 15.2 for Lombardy, and 139.4 for The Capital Region. The percentages of OHCAs covered by any AED and by 24/7 accessible AEDs are shown in Figure 1. The calculated AED density per 1% bystander defibrillation (for the percentage of OHCAs bystander defibrillated within 100, 250 and 500m of an AED) were 34.9, 17.5 and 15.6 for Ticino, 76.0, 50.7 and 38.0 for Lombardy and 19.4, 12.6 and 11.2 for The Capital Region.
Conclusion:
We found great variation in both AED coverage and 24/7 AED accessibility across regions, as well as marked differences in bystander defibrillation according to local AED density. Other factors like geographical differences in the regions, optimal AED placement and citizen responder programs for AED use might explain the observed differences.
Ovid Technologies (Wolters Kluwer Health)
Title: Abstract 13298: Density, Coverage and Usage of Automated External Defibrillators in Out-of-Hospital Cardiac Arrest Across Europe
Description:
Introduction:
Though deployment of Automated External Defibrillators (AEDs) is increasing rapidly, AEDs are often deployed in an un-strategic manner.
Consequently, little is known about the association between AED density, AED coverage of out-of-hospital cardiac arrest (OHCA), and bystander defibrillation across different countries.
This study aimed to investigate the differences in AED densities (AEDS/100,000 inhabitants/1,000 km2), the AED coverage of OHCAs, and bystander defibrillation across Europe.
Hypothesis:
AED density is directly associated with degree of bystander defibrillation across Europe.
Methods:
The study is a European Sudden Cardiac Arrest network towards Prevention, Education, New Effective Treatment (ESCAPE-NET) project.
We included data from Ticino (Switzerland), Lombardy (Italy), and The Capital Region (Denmark) from 2019, covering over 3.
7 million inhabitants.
AED accessibility was defined as the AED being accessible 24/7 or not and AED coverage was defined as the OHCA being covered by an AED within 100, 250 and 500 meters.
AED coverages were calculated the same way by all participants using a free software program (QGIS).
Results:
AED densities were: 87.
3 for Ticino, 15.
2 for Lombardy, and 139.
4 for The Capital Region.
The percentages of OHCAs covered by any AED and by 24/7 accessible AEDs are shown in Figure 1.
The calculated AED density per 1% bystander defibrillation (for the percentage of OHCAs bystander defibrillated within 100, 250 and 500m of an AED) were 34.
9, 17.
5 and 15.
6 for Ticino, 76.
0, 50.
7 and 38.
0 for Lombardy and 19.
4, 12.
6 and 11.
2 for The Capital Region.
Conclusion:
We found great variation in both AED coverage and 24/7 AED accessibility across regions, as well as marked differences in bystander defibrillation according to local AED density.
Other factors like geographical differences in the regions, optimal AED placement and citizen responder programs for AED use might explain the observed differences.
Related Results
Macroeconomic and Social Precursors of Suicide Rates in the Philippines: A Quantitative Analysis (Preprint)
Macroeconomic and Social Precursors of Suicide Rates in the Philippines: A Quantitative Analysis (Preprint)
BACKGROUND
Suicide is a complex, serious and multifaceted public health issue that poses significant challenges to societies worldwide. In fact, it represen...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract
Introduction
Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Linking White‐Tailed Deer Density, Nutrition, and Vegetation in a Stochastic Environment
Linking White‐Tailed Deer Density, Nutrition, and Vegetation in a Stochastic Environment
ABSTRACT
Density‐dependent behavior underpins white‐tailed deer (
Odocoileus virginianus
) theory and...
Quality of Life and Psychological Status of Patients With Implantable Cardioverter Defibrillators
Quality of Life and Psychological Status of Patients With Implantable Cardioverter Defibrillators
• Background Implantable cardioverter defibrillators reduce mortality in patients at high risk for sudden cardiac death and in patients with heart failure. Patients with defibrilla...
History of the Development of Automated External Defibrillators
History of the Development of Automated External Defibrillators
This chapter is structured as a historical overview of the history of the development of defibrillators and the most prominent personalities who contributed to the development of t...
Availability and use of Automated External Defibrillators in Karachi, Pakistan: a cross-sectional study
Availability and use of Automated External Defibrillators in Karachi, Pakistan: a cross-sectional study
Objective: To assess the availability and use of automated external defibrillators in various public and private establishments, and to assess knowledge, attitude and practices rel...
Most Significant Factors Affecting the Survival of Patients with Out-of-hospital Cardiac Arrest
Most Significant Factors Affecting the Survival of Patients with Out-of-hospital Cardiac Arrest
Introduction: Cardiac arrest, the sudden loss of heart function, often strikes without warning. Immediate medical intervention is not only critical, but it is also a lifeline for t...
PELATIHAN BASIC LIFE SUPPORT KORBAN HENTI JANTUNG DI LUAR RUMAH SAKIT DI KELURAHAN MARGA RAHAYU KOTA LUBUKLINGGAU
PELATIHAN BASIC LIFE SUPPORT KORBAN HENTI JANTUNG DI LUAR RUMAH SAKIT DI KELURAHAN MARGA RAHAYU KOTA LUBUKLINGGAU
ABSTRAKKasus henti jantung bisa terjadi dimana saja dan kapan saja. Berdasarkan data statistik, sebagian besar serangan jantung terjadi di luar rumah sakit. Akan tetapi pengetahuan...