Test-Retest and Inter-Rater Reliability of the 20-Meter Ambulation Test in Patients with Parkinson's Disease
View through CrossRef
Objective: In patients with Parkinson’s disease, limited sit-to-stand, walk and turn contribute to decreased independence and quality of life. The 20-meter Ambulation Test (AT20) evaluates walking a total of 20 m, over a 10-m distance, back and forth between 2 chairs, starting and ending in a seated position. The aim of this study was to evaluate test-retest and inter-rater reliability of the AT20 in patients with Parkinson’s disease.Methods: Patients with idiopathic Parkinson’s disease performed the AT20 in 3 conditions: free speed, fast speed, and with large steps, twice 1 week apart. The total number of steps and the time to complete the task were recorded manually by 4 independent raters. The main outcome criteria were the test-retest and inter-rater intraclass correlation coefficients and coefficients of variation for speed, step length and cadence in the 3 conditions.Results: Twenty participants completed the 2 visits. Across all conditions, test-retest and inter-rater intraclass correlation coefficients for step length and speed were > 95%. Test-retest and inter-rater coefficients of variation were < 0.08.Conclusion: The AT20 is a reliable ambulation test in Parkinson’s disease, with excellent test-retest and inter-rater reliability for step length and speed in all 3 conditions: at free speed, fast speed, and with large steps. The AT20 might be useful to assess ambulation in parkinsonism in clinical practice.
LAY ABSTRACTIn patients with Parkinson’s disease, limited sit-tostand, walk and turn contribute to decreased autonomy and quality of life. The 20-meter Ambulation Test (AT20) evaluates walking for a total of 20 m, over a 10 m distance, back and forth between 2 chairs, starting and ending in a seated position. The aim of the current study was to evaluate test-retest and inter-rater reliability for speed, step length and cadence measurement using the AT20 in subjects with Parkinson’s disease. Twenty patients with idiopathic Parkinson’s disease performed the AT20 in 3 conditions: free speed, fast speed, and with large steps, twice 1 week apart. The total number of steps and the time to complete the task were recorded manually by 4 independent raters. The AT20 is a reliable ambulation test in Parkinson’s disease, with excellent reliability between tests and between raters in all 3 conditions: free speed, fast speed, and with large steps. The AT20 might be useful in clinical practice to assess ambulation disorders in patients with parkinsonism.
Title: Test-Retest and Inter-Rater Reliability of the 20-Meter Ambulation Test in Patients with Parkinson's Disease
Description:
Objective: In patients with Parkinson’s disease, limited sit-to-stand, walk and turn contribute to decreased independence and quality of life.
The 20-meter Ambulation Test (AT20) evaluates walking a total of 20 m, over a 10-m distance, back and forth between 2 chairs, starting and ending in a seated position.
The aim of this study was to evaluate test-retest and inter-rater reliability of the AT20 in patients with Parkinson’s disease.
Methods: Patients with idiopathic Parkinson’s disease performed the AT20 in 3 conditions: free speed, fast speed, and with large steps, twice 1 week apart.
The total number of steps and the time to complete the task were recorded manually by 4 independent raters.
The main outcome criteria were the test-retest and inter-rater intraclass correlation coefficients and coefficients of variation for speed, step length and cadence in the 3 conditions.
Results: Twenty participants completed the 2 visits.
Across all conditions, test-retest and inter-rater intraclass correlation coefficients for step length and speed were > 95%.
Test-retest and inter-rater coefficients of variation were < 0.
08.
Conclusion: The AT20 is a reliable ambulation test in Parkinson’s disease, with excellent test-retest and inter-rater reliability for step length and speed in all 3 conditions: at free speed, fast speed, and with large steps.
The AT20 might be useful to assess ambulation in parkinsonism in clinical practice.
LAY ABSTRACTIn patients with Parkinson’s disease, limited sit-tostand, walk and turn contribute to decreased autonomy and quality of life.
The 20-meter Ambulation Test (AT20) evaluates walking for a total of 20 m, over a 10 m distance, back and forth between 2 chairs, starting and ending in a seated position.
The aim of the current study was to evaluate test-retest and inter-rater reliability for speed, step length and cadence measurement using the AT20 in subjects with Parkinson’s disease.
Twenty patients with idiopathic Parkinson’s disease performed the AT20 in 3 conditions: free speed, fast speed, and with large steps, twice 1 week apart.
The total number of steps and the time to complete the task were recorded manually by 4 independent raters.
The AT20 is a reliable ambulation test in Parkinson’s disease, with excellent reliability between tests and between raters in all 3 conditions: free speed, fast speed, and with large steps.
The AT20 might be useful in clinical practice to assess ambulation disorders in patients with parkinsonism.
Related Results
Intra‐ and Inter‐Rater Reliability of Tongue Physical Function Assessments in Children
Intra‐ and Inter‐Rater Reliability of Tongue Physical Function Assessments in Children
ABSTRACT
Background
Tongue function is critical for essential activities such as feeding and sleep. In particular, tongue...
Reliability of visual and instrumental color matching
Reliability of visual and instrumental color matching
AbstractObjectiveThe aim of this investigation was to evaluate intra‐rater and inter‐rater reliability of visual and instrumental shade matching.Materials and MethodsForty individu...
Domination of Polynomial with Application
Domination of Polynomial with Application
In this paper, .We .initiate the study of domination. polynomial , consider G=(V,E) be a simple, finite, and directed graph without. isolated. vertex .We present a study of the Ira...
Clinical validation of a machine‐learning‐based handheld 3‐dimensional infrared wound imaging device in venous leg ulcers
Clinical validation of a machine‐learning‐based handheld 3‐dimensional infrared wound imaging device in venous leg ulcers
AbstractChronic venous insufficiency is a chronic disease of the venous system with a prevalence of 25% to 40% in females and 10% to 20% in males. Venous leg ulcers (VLUs) result f...
Intra-rater and inter-rater reliability of the landing error scoring system-real time (LESS-RT) in college level volleyball and basketball players
Intra-rater and inter-rater reliability of the landing error scoring system-real time (LESS-RT) in college level volleyball and basketball players
Abstract
Anterior Cruciate Ligament (ACL) injury is highly prevalent among volleyball and basketball players and has a significant impact on the athlete’s career....
Time to early ambulation and its predictors among admitted patients undergoing abdominal surgery in East Gojjam Zone Public Hospitals, Northwest Ethiopia
Time to early ambulation and its predictors among admitted patients undergoing abdominal surgery in East Gojjam Zone Public Hospitals, Northwest Ethiopia
Introduction: Early ambulation has demonstrated numerous benefits in the postoperative period. Despite the recognized advantages of early ambulation, there exists considerable vari...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Clinical validation of an artificial intelligence‐enabled wound imaging mobile application in diabetic foot ulcers
Clinical validation of an artificial intelligence‐enabled wound imaging mobile application in diabetic foot ulcers
AbstractThere is a lifetime risk of 15% to 25% of development of diabetic foot ulcers (DFUs) in patients with diabetes mellitus. DFUs need to be followed up on and assessed for dev...