Javascript must be enabled to continue!
Transcatheter Edge-to-Edge Repair of the Mitral Valve in Four Dogs
View through CrossRef
Mitral valve disease is a common heart disease in dogs. The aim of this study was to describe the cases of dogs who underwent mitral valve repair using a v-clamp device and to provide their long-term follow-up data on cardiac function after mitral valve repair. Four dogs with mitral valve regurgitation who experienced coughing and dyspnea underwent surgical mitral valve repair between December 2023 and June 2024. The patients were evaluated by transthoracic and transesophageal echocardiography. Echocardiography revealed mitral valve leaflet regurgitation. Mitral valve repair was performed under general anesthesia using a v-clamp device introduced through an introducer wire guide. Echocardiography was conducted at baseline and the 6-month follow-up. Blood analysis results after surgical repair were normal. Follow-up echocardiography revealed no complications related to the procedure, with all dogs demonstrating improved respiratory signs and quality of life after repair. No adverse reactions were reported after surgery. A v-clamp device was used to repair mitral valve regurgitation in four dogs. Mitral valve repair using a v-clamp device is another treatment option for mitral valve disease in dogs.
Title: Transcatheter Edge-to-Edge Repair of the Mitral Valve in Four Dogs
Description:
Mitral valve disease is a common heart disease in dogs.
The aim of this study was to describe the cases of dogs who underwent mitral valve repair using a v-clamp device and to provide their long-term follow-up data on cardiac function after mitral valve repair.
Four dogs with mitral valve regurgitation who experienced coughing and dyspnea underwent surgical mitral valve repair between December 2023 and June 2024.
The patients were evaluated by transthoracic and transesophageal echocardiography.
Echocardiography revealed mitral valve leaflet regurgitation.
Mitral valve repair was performed under general anesthesia using a v-clamp device introduced through an introducer wire guide.
Echocardiography was conducted at baseline and the 6-month follow-up.
Blood analysis results after surgical repair were normal.
Follow-up echocardiography revealed no complications related to the procedure, with all dogs demonstrating improved respiratory signs and quality of life after repair.
No adverse reactions were reported after surgery.
A v-clamp device was used to repair mitral valve regurgitation in four dogs.
Mitral valve repair using a v-clamp device is another treatment option for mitral valve disease in dogs.
Related Results
Transcatheter Edge-to-Edge Repair of the Mitral Valve in Four Dogs
Transcatheter Edge-to-Edge Repair of the Mitral Valve in Four Dogs
Mitral valve disease is a common heart disease in dogs. The aim of this study was to describe the cases of dogs who underwent mitral valve repair using a v-clamp device and to prov...
Transcatheter mitral valve-in-valve implantation: a 10-year single center experience
Transcatheter mitral valve-in-valve implantation: a 10-year single center experience
Abstract
Background
Transcatheter mitral valve-in-valve (TMVIV) appears a reasonable alternative to surgical redo mitral valve r...
Recurrence of Mitral Valve Regurgitation After Mitral Valve Repair in Degenerative Valve Disease
Recurrence of Mitral Valve Regurgitation After Mitral Valve Repair in Degenerative Valve Disease
Background—
Durability assessment of mitral valve repair for degenerative valve incompetence is actually limited to reoperation as the primary indicator, w...
Early results of mitral vavle repair of degenerative mitral valve regurgitation
Early results of mitral vavle repair of degenerative mitral valve regurgitation
Background: Mitral valve regurgitation due to degenerative valve disease is a common disease affecting about 2% of the population, mainly in developed countries [2],[6]. Medical t...
Update on surgical repair in functional mitral valve regurgitation.
Update on surgical repair in functional mitral valve regurgitation.
Background: Functional mitral regurgitation (FMR) is common in patients
with myocardial infarction or dilated cardiomyopathies, and portends a
poor prognosis despite guideline-dire...
Mitral valve surgery after a failed MitraClip procedure
Mitral valve surgery after a failed MitraClip procedure
Abstract
OBJECTIVES
Among patients undergoing transcatheter mitral valve repair with the MitraClip device, a relevant proportion...
Mitral leaflet separation index correlation with mitral stenosis severity, a reliable easy 2-d echocardiography technique
Mitral leaflet separation index correlation with mitral stenosis severity, a reliable easy 2-d echocardiography technique
Objective: To evaluate accuracy of mitral leaflet separation index for the determination of mitral stenosis severity in patients with rheumatic mitral stenosis.
Method: The prospec...
Mitral Valve Repair in Nursing Care
Mitral Valve Repair in Nursing Care
Background: Mitral valve disease, particularly mitral regurgitation and mitral stenosis, represents a significant cause of cardiovascular morbidity and mortality worldwide. Mitral ...

