Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Development of a Stepping Force Analgesic Meter for a Rat Arthritic Model

View through CrossRef
Behavioural assessment of experimental pain is an essential method for analysing and measuring pain levels. Rodent models, which are widely used in behavioural tests, are often subject to external forces and stressful manipulations that cause variability of the parameters measured during the experiment. Therefore, these parameters may be inappropriate as indicators of pain. In this article, a stepping-force analgesimeter was designed to investigate the variations in the stepping force of rats in response to pain induction. The proposed apparatus incorporates new features, namely an infrared charge-coupled device (CCD) camera and a data acquisition system. The camera was able to capture the locomotion of the rats and synchronise the stepping force concurrently so that each step could be identified. Inter-day and intra-day precision and accuracy of each channel (there were a total of eight channels in the analgesimeter and each channel was connected to one load cell and one amplifier) were studied using different standard load weights. The validation studies for each channel also showed convincing results whereby intra-day and inter-day precision were less than 1% and accuracy was 99.36–100.36%. Consequently, an in vivo test was carried out using 16 rats (eight females and eight males). The rats were allowed to randomly walk across the sensor tunnel (the area that contained eight channels) and the stepping force and locomotion were recorded. A non-expert, but from a related research domain, was asked to differentiate the peaks of the front and hind paw, respectively. The results showed that of the total movement generated by the rats, 50.27 ± 3.90% in the case of the male rats and 62.20 ± 6.12% in that of the female rats had more than two peaks, a finding which does not substantiate the assumptions made in previous studies. This study also showed that there was a need to use the video display frame to distinguish between the front and hind paws in the case of 48.80 ± 4.01% of the male rats and 66.76 ± 5.35% of the female rats. Evidently the assumption held by current researchers regarding stepping force measurement is not realistic in terms of application, and as this study has shown, the use of a video display frame is essential for the identification of the front and hind paws through the peak signals.
Title: Development of a Stepping Force Analgesic Meter for a Rat Arthritic Model
Description:
Behavioural assessment of experimental pain is an essential method for analysing and measuring pain levels.
Rodent models, which are widely used in behavioural tests, are often subject to external forces and stressful manipulations that cause variability of the parameters measured during the experiment.
Therefore, these parameters may be inappropriate as indicators of pain.
In this article, a stepping-force analgesimeter was designed to investigate the variations in the stepping force of rats in response to pain induction.
The proposed apparatus incorporates new features, namely an infrared charge-coupled device (CCD) camera and a data acquisition system.
The camera was able to capture the locomotion of the rats and synchronise the stepping force concurrently so that each step could be identified.
Inter-day and intra-day precision and accuracy of each channel (there were a total of eight channels in the analgesimeter and each channel was connected to one load cell and one amplifier) were studied using different standard load weights.
The validation studies for each channel also showed convincing results whereby intra-day and inter-day precision were less than 1% and accuracy was 99.
36–100.
36%.
Consequently, an in vivo test was carried out using 16 rats (eight females and eight males).
The rats were allowed to randomly walk across the sensor tunnel (the area that contained eight channels) and the stepping force and locomotion were recorded.
A non-expert, but from a related research domain, was asked to differentiate the peaks of the front and hind paw, respectively.
The results showed that of the total movement generated by the rats, 50.
27 ± 3.
90% in the case of the male rats and 62.
20 ± 6.
12% in that of the female rats had more than two peaks, a finding which does not substantiate the assumptions made in previous studies.
This study also showed that there was a need to use the video display frame to distinguish between the front and hind paws in the case of 48.
80 ± 4.
01% of the male rats and 66.
76 ± 5.
35% of the female rats.
Evidently the assumption held by current researchers regarding stepping force measurement is not realistic in terms of application, and as this study has shown, the use of a video display frame is essential for the identification of the front and hind paws through the peak signals.

Related Results

PROCEEDINGS OF THE AUSTRALASIAN SOCIETY OF CLINICAL AND EXPERIMENTAL PHARMACOLOGISTS
PROCEEDINGS OF THE AUSTRALASIAN SOCIETY OF CLINICAL AND EXPERIMENTAL PHARMACOLOGISTS
1.Effect of chronic haloperidol treatment on D‐2 receptors labelled by (3H)‐spiperone in homogenates of rat corpus striatum. A. L. Gundlach, D. J. de Vries and P. M. Beart2.The eff...
Does Ability to do Proactive Stepping Reflect Ability to do Reactive Stepping?
Does Ability to do Proactive Stepping Reflect Ability to do Reactive Stepping?
Stepping is the strategy used in standing to prevent fall. Reactive stepping is made when perturbed to fall. Reactive stepping is less assessed in clinical setting, instead, proact...
PROCEEDINGS OF THE AUSTRALASIAN SOCIETY OF CLINICAL AND EXPERIMENTAL PHARMACOLOGISTS
PROCEEDINGS OF THE AUSTRALASIAN SOCIETY OF CLINICAL AND EXPERIMENTAL PHARMACOLOGISTS
14th Annual Meeting, December 1980, Canberra1. Effect of dexamethasone on pineal β‐adrenoceptors. C. A. Maxwell, A. Foldes, N. T. Hinks and R. M. Hoskinson2. A clinicopathological ...
Domestic water meter optimal replacement period to minimize water revenue loss
Domestic water meter optimal replacement period to minimize water revenue loss
Water meter under-registration results in apparent losses and lost revenue for municipalities. Municipalities should scientifically determine the optimal replacement periods for th...
PROCEEDINGS OF THE AUSTRALASIAN SOCIETY OF CLINICAL AND EXPERIMENTAL PHARMACOLOGISTS
PROCEEDINGS OF THE AUSTRALASIAN SOCIETY OF CLINICAL AND EXPERIMENTAL PHARMACOLOGISTS
1. The development of the prejunctional receptor hypothesis. M.W. McCulloch, M.J. Rand and D. F. Story2. Adrenoceptor‐ and cholinoceptor‐mediated modulation of transmitter release ...
Study of Analgesic Activity of Methanolic Extracts of Cuminum Cyminum (L.) and Centratherum Anthelminticum (L.) in Mice
Study of Analgesic Activity of Methanolic Extracts of Cuminum Cyminum (L.) and Centratherum Anthelminticum (L.) in Mice
Objective: This study was conducted to investigate and compare the analgesic activity of methanolic ex- tracts of seeds of Cuminum Cyminum (L) and Centratherum anthelminticum (L)in...
Effects of ω‐conotoxin GVIA on autonomic neuroeffector transmission in various tissues
Effects of ω‐conotoxin GVIA on autonomic neuroeffector transmission in various tissues
The effects of ω‐conotoxin GVIA (conotoxin), a potent inhibitor of neuronal N‐type Ca2+ channels, have been examined on responses to stimulation of noradrenergic, cholinergic and n...

Back to Top