Javascript must be enabled to continue!
Insulating Gas Mask with Hybrid Air Duct Design and Unevenly Loaded Regenerative Cartridge
View through CrossRef
According to stoichiometric estimates, less than half of the protective resource of an insulating mask with chemical oxygen redundancy is used by the moment of critical breakthrough of exhaled СО2 through the regenerative cartridge. One of the causes is the destruction of the porous structure of oxygen-containing product granules affected by exothermic heat emitted during the chemisorption of exhaled СО2 molecules. The second cause is the dead layer of the product remaining unused by the end of the protective action of the gas mask when air with 1.5 % carbon dioxide content starts leaving the regenerative cartridge. In order to eliminate these causes, mathematical and computer modeling of air regeneration in the gas mask for chemically bound oxygen with a hybrid (circular pendulum) air duct design and enlarged granules of potassium superoxide at the inlet to the regenerative cartridge have been performed.
It has been shown that the enlargement of granule size by 25 % reduces by more than one-third the rate of heat emission in them when binding exhaled СО2 molecules, which softens the cartridge's thermal regime and preserves the granules' porosity. The length of the part of the cartridge with enlarged granules is determined based on the condition of the equal rate of СО2 absorption at the inlet to the first and second (with non-enlarged granule size) parts of the cartridge.
The efficiency of the use of the breathing device’s protective resource is also increased by the reverse of airflow in the dead layer of oxygen-containing product. The length of the pendulum part of the regenerative cartridge that ensures the maximum (by 8.1 %) increase in the use of the product’s dead layer and prevents air filtration through the spent layers of oxygen-containing product has been determined.
STC Industry Safety CJSC
Title: Insulating Gas Mask with Hybrid Air Duct Design and Unevenly Loaded Regenerative Cartridge
Description:
According to stoichiometric estimates, less than half of the protective resource of an insulating mask with chemical oxygen redundancy is used by the moment of critical breakthrough of exhaled СО2 through the regenerative cartridge.
One of the causes is the destruction of the porous structure of oxygen-containing product granules affected by exothermic heat emitted during the chemisorption of exhaled СО2 molecules.
The second cause is the dead layer of the product remaining unused by the end of the protective action of the gas mask when air with 1.
5 % carbon dioxide content starts leaving the regenerative cartridge.
In order to eliminate these causes, mathematical and computer modeling of air regeneration in the gas mask for chemically bound oxygen with a hybrid (circular pendulum) air duct design and enlarged granules of potassium superoxide at the inlet to the regenerative cartridge have been performed.
It has been shown that the enlargement of granule size by 25 % reduces by more than one-third the rate of heat emission in them when binding exhaled СО2 molecules, which softens the cartridge's thermal regime and preserves the granules' porosity.
The length of the part of the cartridge with enlarged granules is determined based on the condition of the equal rate of СО2 absorption at the inlet to the first and second (with non-enlarged granule size) parts of the cartridge.
The efficiency of the use of the breathing device’s protective resource is also increased by the reverse of airflow in the dead layer of oxygen-containing product.
The length of the pendulum part of the regenerative cartridge that ensures the maximum (by 8.
1 %) increase in the use of the product’s dead layer and prevents air filtration through the spent layers of oxygen-containing product has been determined.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Presentation and Management of Cervical Thoracic Duct Cyst: A Systematic Review of the Literature
Presentation and Management of Cervical Thoracic Duct Cyst: A Systematic Review of the Literature
Abstract
Introduction
Thoracic duct cysts are an uncommon phenomenon, especially within the cervical region. Due to its limited reported cases, very little is known about its etiol...
Isolated cystic duct cyst in a child :A case report
Isolated cystic duct cyst in a child :A case report
Abstract
Background:
Dilatation of the common bile duct is a common biliary malformation in children. However, isolated cysts of the cystic duct are extremely rare and not ...
Optimal design of a ram air cooling duct housing the condenser of an airborne ORC WHR unit
Optimal design of a ram air cooling duct housing the condenser of an airborne ORC WHR unit
Thermal energy harvesting from aero engines using compact organic Rankine cycle (ORC) units can reduce aircraft fuel consumption and emissions. Heat exchangers (HX) are key compone...
Light Weight Aluminum Cartridge Case Design for IED’s Application - ANSYS
Light Weight Aluminum Cartridge Case Design for IED’s Application - ANSYS
This paper describes the design analysis of the aluminum cartridge case, its testing, Analytical Simulation (ANSYS) and evaluation against Improvised Explosive Devices (IEDs) appli...
Design of Duct Passages for an Air Turbine Starter Test Rig
Design of Duct Passages for an Air Turbine Starter Test Rig
Abstract
In a typical air turbine starter (ATS) engine testing application, compressed air is supplied to the turbine by means of an inlet duct usually with a 90 deg...
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Exposure to volatile organic compounds (VOC) in workplaces can cause acute effects such as irritation of the skin, the eyes, the mouth, and the nose. Some products may also cause c...
Salivary Mucocele Secondary to Parotid Duct Obstruction by Grass in a Dog
Salivary Mucocele Secondary to Parotid Duct Obstruction by Grass in a Dog
Background: Salivary mucocele results from the accumulation of saliva secondary to salivary gland or duct injury. Its etiology remains poorly understood, with limited reports on th...

