Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Air/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurised Water Reactor

View through CrossRef
Different scenarios of small break Loss of Coolant Accident (LOCA) for pressurised water reactors (PWR) lead to the reflux-condenser mode in which steam enters the hot leg from the reactor pressure vessel (RPV) and condenses in the steam generator. A part of the condensate flows back towards the RPV in counter current to the steam. During the reflux-condenser mode, a counter-current flow limitation (CCFL) must be prevented because this would limit the core cooling. The simulation of CCFL conditions, which is dominated by 3D effects, requires the use of a computational fluid dynamics (CFD) approach. These methods are not yet mature and have to be validated before they can be applied to nuclear reactor safety. Therefore, dedicated experimental data is needed with high resolution in space and time. In order to investigate the two-phase flow behaviour in a complex reactor-typical geometry and to supply suitable data for CFD code validation, the “hot leg model” was built at Forschungszentrum Dresden-Rossendorf (FZD). This setup is devoted to optical measurement techniques, therefore, a flat test-section design was chosen with a width of 50 mm. The test-section outlines represent the hot leg of a German Konvoi PWR at a scale of 1:3, which corresponds to a channel height of 250 mm in the straight part of the hot leg. The test-section is mounted between two separators, one simulating the reactor pressure vessel and the other is connected to the steam generator inlet chamber. This allows to perform co-current as well as counter-current flow experiments. Moreover, the hot leg model is built in the pressure vessel of the TOPFLOW facility of FZD, which is used to perform high-pressure experiments under pressure equilibrium with the inside atmosphere of the vessel. Therefore, the test section can be designed with thin materials and equipped with big size windows like in the hot leg model. The presented air/water experiments focus on the flow structure observed in the region of the riser and of the steam generator inlet chamber at room temperature and pressures up to 3 bars. The performed high-speed observations show the evolution of the stratified interface and the distribution of the two-phase mixture (droplet and bubbles). Counter-current flow limitation, or the onset of flooding, was found by analysing the water levels measured in the separators. A confrontation with the images indicates that the initiation of flooding coincides with the reversal of the flow in the horizontal part of the hot leg due to high air velocities. Afterwards, bigger waves are generated, which develop to slugs. Furthermore, the CCFL data was compared with similar experiments and empirical correlations available in the literature. The agreement of the CCFL curve is good and indicate that the data is relevant for CFD validation purposes. The zero penetration was found at lower values of the Wallis parameter than in most of the previous work, which can be attributed to the rectangular geometry of the hot leg model.
Title: Air/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurised Water Reactor
Description:
Different scenarios of small break Loss of Coolant Accident (LOCA) for pressurised water reactors (PWR) lead to the reflux-condenser mode in which steam enters the hot leg from the reactor pressure vessel (RPV) and condenses in the steam generator.
A part of the condensate flows back towards the RPV in counter current to the steam.
During the reflux-condenser mode, a counter-current flow limitation (CCFL) must be prevented because this would limit the core cooling.
The simulation of CCFL conditions, which is dominated by 3D effects, requires the use of a computational fluid dynamics (CFD) approach.
These methods are not yet mature and have to be validated before they can be applied to nuclear reactor safety.
Therefore, dedicated experimental data is needed with high resolution in space and time.
In order to investigate the two-phase flow behaviour in a complex reactor-typical geometry and to supply suitable data for CFD code validation, the “hot leg model” was built at Forschungszentrum Dresden-Rossendorf (FZD).
This setup is devoted to optical measurement techniques, therefore, a flat test-section design was chosen with a width of 50 mm.
The test-section outlines represent the hot leg of a German Konvoi PWR at a scale of 1:3, which corresponds to a channel height of 250 mm in the straight part of the hot leg.
The test-section is mounted between two separators, one simulating the reactor pressure vessel and the other is connected to the steam generator inlet chamber.
This allows to perform co-current as well as counter-current flow experiments.
Moreover, the hot leg model is built in the pressure vessel of the TOPFLOW facility of FZD, which is used to perform high-pressure experiments under pressure equilibrium with the inside atmosphere of the vessel.
Therefore, the test section can be designed with thin materials and equipped with big size windows like in the hot leg model.
The presented air/water experiments focus on the flow structure observed in the region of the riser and of the steam generator inlet chamber at room temperature and pressures up to 3 bars.
The performed high-speed observations show the evolution of the stratified interface and the distribution of the two-phase mixture (droplet and bubbles).
Counter-current flow limitation, or the onset of flooding, was found by analysing the water levels measured in the separators.
A confrontation with the images indicates that the initiation of flooding coincides with the reversal of the flow in the horizontal part of the hot leg due to high air velocities.
Afterwards, bigger waves are generated, which develop to slugs.
Furthermore, the CCFL data was compared with similar experiments and empirical correlations available in the literature.
The agreement of the CCFL curve is good and indicate that the data is relevant for CFD validation purposes.
The zero penetration was found at lower values of the Wallis parameter than in most of the previous work, which can be attributed to the rectangular geometry of the hot leg model.

Related Results

Muscle Metabolism during Exercise in Hemiparetic Patients
Muscle Metabolism during Exercise in Hemiparetic Patients
1. A group of eight male patients with moderate hemiparesis was studied at rest and during 40 min of exercise on four occasions. Both two-leg and one-leg exercise were performed an...
Air/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurized Water Reactor
Air/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurized Water Reactor
Different scenarios of small break loss of coolant accident for pressurized water reactors (PWRs) lead to the reflux-condenser mode in which steam enters the hot leg from the react...
ANALISIS PENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM
ANALISIS PENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM
ANALISISPENGATURAN POSISI CONTROL RODS PADA KONSEP REAKTOR DAYA EKSPERIMENTAL INDONESIA PASCA REACTOR SCRAM POST REACTOR SCRAM CONTROL RODS POSITION ADJUSTMENT ANALYSIS FOR THE IN...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Narasi Counter-Stereotype Etnis Batak dalam Film Ngeri-Ngeri Sedap (2022)
Narasi Counter-Stereotype Etnis Batak dalam Film Ngeri-Ngeri Sedap (2022)
AbstrakPenelitian ini bertujuan untuk mengetahui bagaimana narasi counter-stereotype direpresentasikan dalam film Ngeri-Ngeri Sedap. Penelitian ini menggunakan metode kualitatif de...
Investigation of Transient Flow and Heat Transfer for Passive Nuclear Reactor Direct Safety Injection
Investigation of Transient Flow and Heat Transfer for Passive Nuclear Reactor Direct Safety Injection
This paper describes a transient flow and heat transfer characteristics for a 1400MW passive pressurized-water reactor (PWR) direct vessel injection (DVI) system in different accid...
Bluetooth Operated Virus Destroyer Cum Room Heater
Bluetooth Operated Virus Destroyer Cum Room Heater
Abstract: The idea introduced here is expected to kill any infection drifting in the air by which air will be decontaminated persistently by killing the miniature creatures like mi...
Air convection in coarse blocky permafrost : a numerical modelling approach to improve the understanding of the ground thermal regime
Air convection in coarse blocky permafrost : a numerical modelling approach to improve the understanding of the ground thermal regime
Permafrost is a thermal phenomenon, defined as subsurface material with a temperature remaining below 0°C for at least two consecutive years. Permafrost occurs at high latitudes an...

Back to Top