Fragility Evaluation in Building-Piping Systems: Effect of Piping Interaction With Buildings
View through CrossRef
Many studies assessing the damage from 1971 San Fernando and 1994 North Ridge earthquakes reported that the failure of nonstructural components like piping systems was one of the significant reasons for shutdown of hospitals immediately after the earthquakes. This paper is focused on evaluating seismic fragility of a large-scale piping system in representative high-rise, midrise, and low-rise buildings using nonlinear time history analyses. The emphasis is on evaluating piping's interaction with building and its effect on piping fragility. The building models include the effects of nonlinearity in the performance of beams and columns. In a 20-story building that is detuned with the piping system, critical locations are on the top two floors for the linear frame building model. For the nonlinear building model, critical locations are on the bottom two floors. In an eight-story building that is nearly tuned with the piping system, the critical locations for both the linear frame and nonlinear models are the third and fourth floors. It is observed that building nonlinearity can reduce fragility due to reduction in the tuning between building and piping systems. In a two-story building, the nonlinear building frequencies are closer to the critical piping system frequencies than the linear building frequency; the nonlinear building is more fragile than the linear building for this case. However, it is observed that the linear building models give excessively conservative estimates of fragility than the nonlinear building models.
Title: Fragility Evaluation in Building-Piping Systems: Effect of Piping Interaction With Buildings
Description:
Many studies assessing the damage from 1971 San Fernando and 1994 North Ridge earthquakes reported that the failure of nonstructural components like piping systems was one of the significant reasons for shutdown of hospitals immediately after the earthquakes.
This paper is focused on evaluating seismic fragility of a large-scale piping system in representative high-rise, midrise, and low-rise buildings using nonlinear time history analyses.
The emphasis is on evaluating piping's interaction with building and its effect on piping fragility.
The building models include the effects of nonlinearity in the performance of beams and columns.
In a 20-story building that is detuned with the piping system, critical locations are on the top two floors for the linear frame building model.
For the nonlinear building model, critical locations are on the bottom two floors.
In an eight-story building that is nearly tuned with the piping system, the critical locations for both the linear frame and nonlinear models are the third and fourth floors.
It is observed that building nonlinearity can reduce fragility due to reduction in the tuning between building and piping systems.
In a two-story building, the nonlinear building frequencies are closer to the critical piping system frequencies than the linear building frequency; the nonlinear building is more fragile than the linear building for this case.
However, it is observed that the linear building models give excessively conservative estimates of fragility than the nonlinear building models.
Related Results
Architecture and adaptation
Architecture and adaptation
«The architectural work transcends the architect, goes beyond the moment in which its construction takes place, and therefore can be contemplated under the changing lights of histo...
De gevel – een intermediair element tussen buiten en binnen
De gevel – een intermediair element tussen buiten en binnen
This study is based on the fact that all people have a basic need for protection from other people (and animals) as well as from the elements (the exterior climate). People need a ...
Low Temperature Piping Support Challenges & Mitigation
Low Temperature Piping Support Challenges & Mitigation
Abstract
Piping systems having service temperatures lower than ambient present a challenge for the pipe support design. Pipe supports for these cold piping systems a...
Safety Restraint System for High-Pressure Oilfield Piping
Safety Restraint System for High-Pressure Oilfield Piping
Abstract
Conveying energized fluid through piping presents a significant hazard with the potential for explosion in the event of a component failure. A method is ...
Comparative assessment of environmental and post- occupancy evaluation of green buildings vs conventional buildings
Comparative assessment of environmental and post- occupancy evaluation of green buildings vs conventional buildings
Due to increasing office space demand and rising rental rates, stakeholders seek cost-effective alternatives that align with sustainability goals. Therefore, green building offers ...
Ensuring the Reliability of Offshore Gas Compression Systems
Ensuring the Reliability of Offshore Gas Compression Systems
Summary
Selection of offshore gas equipment is based on intended application, efficiency, reliability, and compatibility with platform structural requirements. Th...
Fragility Curves for Italian Urm Buildings Based on a Hybrid Method
Fragility Curves for Italian Urm Buildings Based on a Hybrid Method
Abstract
A hybrid seismic fragility model for territorial-scale seismic vulnerability assessment of masonry buildings is developed and presented in this paper. The method c...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract
The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...