Javascript must be enabled to continue!
A Lead‐Selective Membrane Electrode Based Upon a Phosphorylated Hexahomotrioxacalix[3]Arene
View through CrossRef
AbstractSolvent extraction of a mixture of PbII, MnII, FeIII, CoII, NiIIand CdIIin aqueous perchlorate medium by a phosphorylated hexahomotrioxacalix[3]arene (calix‐3) in dichloromethane shows a significant selectivity towards lead ions. The ligand can also be incorporated into a membrane to provide a new lead ion‐selective electrode (PbII‐ISE). A plasticized PVC membrane containing 30% PVC, 53.5%ortho‐nitrophenyloctylether (NPOE), 4.5% sodium tetraphenylborate (NaTPB) and 12% ionophore was directly coated on a graphite rod. This sensor gave a good Nernstian response of 29.7 ± 0.7 mV decade−1over a concentration range of 1 × 10−8– 1 × 10−4M of lead ions, independent of pH in the range 3‐7, with a detection limit of 0.4 × 10−8M. The dynamic response time of the electrode to achieve a steady potential was very fast and found to be less than 7 s. The selectivity relative to Ag+, NH4+, Li+, Na+, K+, Ca2+, Sr2+, Ba2+, Mn2+, Fe2+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+, Fe3+, La3+, Sm3+, Dy3+, Er3+, Y3+and Th4+was examined. The electrode exhibits adequate stability with good reproducibility (with a slope of 29.6 ± 1.5 mV for 8 weeks). The characteristics of the sensor are compared with those of a tetraphosphorylated calix[4]arene (calix‐4) based PbII‐ISE, reported recently. The electrode was successfully used as an indicator electrode for a potentiometric titration of a lead solution using a standard solution of EDTA. The applicability of the sensor for lead ion measurements in various synthetic samples was also investigated.
Title: A Lead‐Selective Membrane Electrode Based Upon a Phosphorylated Hexahomotrioxacalix[3]Arene
Description:
AbstractSolvent extraction of a mixture of PbII, MnII, FeIII, CoII, NiIIand CdIIin aqueous perchlorate medium by a phosphorylated hexahomotrioxacalix[3]arene (calix‐3) in dichloromethane shows a significant selectivity towards lead ions.
The ligand can also be incorporated into a membrane to provide a new lead ion‐selective electrode (PbII‐ISE).
A plasticized PVC membrane containing 30% PVC, 53.
5%ortho‐nitrophenyloctylether (NPOE), 4.
5% sodium tetraphenylborate (NaTPB) and 12% ionophore was directly coated on a graphite rod.
This sensor gave a good Nernstian response of 29.
7 ± 0.
7 mV decade−1over a concentration range of 1 × 10−8– 1 × 10−4M of lead ions, independent of pH in the range 3‐7, with a detection limit of 0.
4 × 10−8M.
The dynamic response time of the electrode to achieve a steady potential was very fast and found to be less than 7 s.
The selectivity relative to Ag+, NH4+, Li+, Na+, K+, Ca2+, Sr2+, Ba2+, Mn2+, Fe2+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+, Fe3+, La3+, Sm3+, Dy3+, Er3+, Y3+and Th4+was examined.
The electrode exhibits adequate stability with good reproducibility (with a slope of 29.
6 ± 1.
5 mV for 8 weeks).
The characteristics of the sensor are compared with those of a tetraphosphorylated calix[4]arene (calix‐4) based PbII‐ISE, reported recently.
The electrode was successfully used as an indicator electrode for a potentiometric titration of a lead solution using a standard solution of EDTA.
The applicability of the sensor for lead ion measurements in various synthetic samples was also investigated.
Related Results
Procedure for Western blot v1
Procedure for Western blot v1
Goal: This document has the objective of standardizing the protocol for Western blot. This technique allows the detection of specific proteins separated on polyacrylamide gel and t...
Proton Polymer Electrolytes in Fuel Cell
Proton Polymer Electrolytes in Fuel Cell
The electrolyte is one of the main parts of a fuel cell. That is divided into liquid and solid and it is used in both Alkaline and acidulous PH. But with due to kind of electrolyte...
Trace Mercury Ion Detection Sensor Employing SnO2/Rgo Nanocomposites Modified Electrode
Trace Mercury Ion Detection Sensor Employing SnO2/Rgo Nanocomposites Modified Electrode
Introduction
Heavy metal pollution seriously affects human health. Mercury is one of the most hazardous pollution, it has been accum...
Design principles for robust vesiculation in clathrin-mediated endocytosis
Design principles for robust vesiculation in clathrin-mediated endocytosis
AbstractA critical step in cellular trafficking pathways is the budding of membranes by protein coats, which recent experiments have demonstrated can be inhibited by elevated membr...
Applications of Supramolecular Polymers Generated from Pillar[n]arene-Based Molecules
Applications of Supramolecular Polymers Generated from Pillar[n]arene-Based Molecules
Supramolecular chemistry enables the manipulation of functional components on a molecular scale, facilitating a “bottom-up” approach to govern the sizes and structures of supramole...
Increased Expression of Phosphorylated c-Jun Amino-terminal Kinase and Phosphorylated c-Jun in Human Cerebral Aneurysms: Role of the c-Jun Amino-terminal Kinase/c-Jun Pathway in Apoptosis of Vascular Walls
Increased Expression of Phosphorylated c-Jun Amino-terminal Kinase and Phosphorylated c-Jun in Human Cerebral Aneurysms: Role of the c-Jun Amino-terminal Kinase/c-Jun Pathway in Apoptosis of Vascular Walls
Abstract
OBJECTIVE
Vascular remodeling via apoptotic mechanisms is an important factor in vascular diseases. c-Jun amino-termina...
ATN status in amnestic and non-amnestic Alzheimer’s disease and frontotemporal lobar degeneration
ATN status in amnestic and non-amnestic Alzheimer’s disease and frontotemporal lobar degeneration
AbstractUnder the ATN framework, cerebrospinal fluid analytes provide evidence of the presence or absence of Alzheimer’s disease pathological hallmarks: amyloid plaques (A), phosph...
Calix[8]arene‐mediated self‐assembly of tetrapeptide H‐Leu‐Leu‐Ile‐Leu‐OMe
Calix[8]arene‐mediated self‐assembly of tetrapeptide H‐Leu‐Leu‐Ile‐Leu‐OMe
AbstractConformational analysis of peptide 1, H‐Leu‐Leu‐Ile‐Leu‐OMe on complexing with macro cycle calix[8]arene has been carried out using 1H‐NMR and FTIR spectroscopic techniques...

