Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effect of frameless stereotaxy on the accuracy of C1–2 transarticular screw placement

View through CrossRef
Object. In recent studies some authors have indicated that 20% of patients have at least one ectatic vertebral artery (VA) that, based on previous criteria in which preoperative computerized tomography (CT) and standard intraoperative fluoroscopic techniques were used, may prevent the safe placement of C1–2 transarticular screws. The authors conducted this study to determine whether frameless stereotaxy would improve the accuracy of C1–2 transarticular screw placement in healthy patients, particularly those whom previous criteria would have excluded. Methods. The authors assessed the accuracy of frameless stereotaxy for C1–2 transarticular screw placement in 17 cadaveric cervical spines. Preoperatively obtained CT scans of the C-2 vertebra were registered on a stereotactic workstation. The dimensions of the C-2 pars articularis were measured on the workstation, and a 3.5-mm screw was stereotactically placed if the height and width of the pars interarticularis was greater than 4 mm. The specimens were evaluated with postoperative CT scanning and visual inspection. Screw placement was considered acceptable if the screw was contained within the C-2 pars interarticularis, traversed the C1–2 joint, and the screw tip was shown to be within the anterior cortex of the C-1 lateral mass. Transarticular screws were accurately placed in 16 cadaveric specimens, and only one specimen (5.9%) was excluded because of anomalous VA anatomy. In contrast, a total of four specimens (23.5%) showed significant narrowing of the C-2 pars interarticularis due to vascular anatomy that would have precluded atlantoaxial transarticular screw placement had previous nonimage-guided criteria been used. Conclusions. Frameless stereotaxy provides precise image guidance that improves the safety of C1–2 transarticular screw placement and potentially allows this procedure to be performed in patients previously excluded because of the inaccuracy of nonimage-guided techniques.
Title: Effect of frameless stereotaxy on the accuracy of C1–2 transarticular screw placement
Description:
Object.
In recent studies some authors have indicated that 20% of patients have at least one ectatic vertebral artery (VA) that, based on previous criteria in which preoperative computerized tomography (CT) and standard intraoperative fluoroscopic techniques were used, may prevent the safe placement of C1–2 transarticular screws.
The authors conducted this study to determine whether frameless stereotaxy would improve the accuracy of C1–2 transarticular screw placement in healthy patients, particularly those whom previous criteria would have excluded.
Methods.
The authors assessed the accuracy of frameless stereotaxy for C1–2 transarticular screw placement in 17 cadaveric cervical spines.
Preoperatively obtained CT scans of the C-2 vertebra were registered on a stereotactic workstation.
The dimensions of the C-2 pars articularis were measured on the workstation, and a 3.
5-mm screw was stereotactically placed if the height and width of the pars interarticularis was greater than 4 mm.
The specimens were evaluated with postoperative CT scanning and visual inspection.
Screw placement was considered acceptable if the screw was contained within the C-2 pars interarticularis, traversed the C1–2 joint, and the screw tip was shown to be within the anterior cortex of the C-1 lateral mass.
Transarticular screws were accurately placed in 16 cadaveric specimens, and only one specimen (5.
9%) was excluded because of anomalous VA anatomy.
In contrast, a total of four specimens (23.
5%) showed significant narrowing of the C-2 pars interarticularis due to vascular anatomy that would have precluded atlantoaxial transarticular screw placement had previous nonimage-guided criteria been used.
Conclusions.
Frameless stereotaxy provides precise image guidance that improves the safety of C1–2 transarticular screw placement and potentially allows this procedure to be performed in patients previously excluded because of the inaccuracy of nonimage-guided techniques.

Related Results

Study on Positioning Accuracy of Aerostatic Lead Screw
Study on Positioning Accuracy of Aerostatic Lead Screw
The aerostatic lead screw is a non-contact type lead screw in which the contact surface of a male screw and a female screw is supported by a pressurized air film. It is characteriz...
Optimal trajectory for the anterior occipital condyle screw
Optimal trajectory for the anterior occipital condyle screw
Objective This study aimed to assess the practicality and optimal approach for inserting an anterior occipital condyle screw, as well as to measure the screw pl...
Principles of Neuronavigation
Principles of Neuronavigation
Background and Aim: Numerous efforts have been made over the past century. Various innovation techniques are increasingly gaining attention and gradually establishing the foundatio...
Stifle joint luxation in the cat: treatment using transarticular external skeletal fixation
Stifle joint luxation in the cat: treatment using transarticular external skeletal fixation
Extra‐articular suturing techniques and transarticular external skeletal fixators were used to repair traumatic luxation of the stifle joint in four cats. Rupture of the cranial cr...
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Clinical studies reveal remarkable variation in screw patterns, or screw density in spinal instrumentation. Screw density may have a great impact on blood loss, operative time, rad...
Novel Technique for Measurement of Screw Bending in Bone Fixation Constructs
Novel Technique for Measurement of Screw Bending in Bone Fixation Constructs
The focus of the present research was to develop a reliable test method and apparatus to measure bending deflection of individual surgical screws during quasi-static loading of a p...
The largest secure corridor of the infra-acetabular screw — a 3-D axial perspective analysis
The largest secure corridor of the infra-acetabular screw — a 3-D axial perspective analysis
Abstract Background The infra-acetabular screw is placed from the pubis to the ischium and can be used as a special lag screw of the posterior column of the acetabulum. Thi...
The Largest Secure Corridor of the Infra-acetabular Screw—a 3-D Axial Perspective Analysis
The Largest Secure Corridor of the Infra-acetabular Screw—a 3-D Axial Perspective Analysis
Abstract Background The infra-acetabular screw is placed from the pubis to the ischium and can be used as a special lag screw of the posterior column of the acetabulum. Thi...

Back to Top