Javascript must be enabled to continue!
Influence of low temperature on bronchodilatation induced by terbutaline administered by metered dose or dry powder inhalers in asthmatics
View through CrossRef
Abstract— Low temperatures may affect dose delivery efficacy and clinical effectiveness of medication aerosols. In this study we examine the effect of cold ambient temperature on the bronchodilatation produced by terbutaline delivered from a chlorofluorocarbon pressurized metered dose inhaler (pMDl) compared to a multi‐dose dry powder inhaler (DPI). Fourteen stable asthmatics were studied on two consecutive days. On day 1, after measuring FEV1 at room temperature (22 °C), each patient was randomized to receive 500 μg of terbutaline delivered from pMDI or DPI stored for 24 h at 22 °C with FEV1 recorded 20 min post‐dose; then, patients were placed in a chamber at − 10 °C, and after obtaining FEV1, each patient received 500 μg of terbutaline delivered from pMDI or DPI (same formulation as previously administered) stored for 24 h at − 10 °C, and FEV1 was obtained 20 min post‐dose. On day 2, a similar protocol was followed but each patient received terbutaline as the alternative to the formulation administered on day 1. Pairwise comparisons of the FEV1 (% predicted) values obtained on day 1 and day 2 at 22 °C and − 10 °C (pre‐dose) showed no significant differences. Similar bronchodilatations were observed for terbutaline DPI administration at 22 °C and − 10 °C (24.85 ± 11.72 and 20.08 ± 6.27 % increase of FEV1; P>0.05). By contrast, the bronchodilatation obtained for terbutaline pMDI at 22 °C (21.07 ± 8.55% increase in FEV1) was not reproduced at − 10 °C (0.72 ± 2.84%; P < 0.05 from 22 °C). In five asthmatics a cumulative dose‐response curve for terbutaline pMDI was obtained. This part of the study showed that a higher dose of terbutaline pMDI was necessary at − 10 °C to obtain a bronchodilator response (10.04 ± 6.75% increase of FEV1 after 2 000 μg) that remained lower than the bronchodilatation for 500 μg terbutaline pMDI at − 10 °C. In conclusion, the clinical effectiveness of terbutaline delivered from chlorofluorocarbon pMDIs is compromised by cold storage while DPIs are not affected.
Title: Influence of low temperature on bronchodilatation induced by terbutaline administered by metered dose or dry powder inhalers in asthmatics
Description:
Abstract— Low temperatures may affect dose delivery efficacy and clinical effectiveness of medication aerosols.
In this study we examine the effect of cold ambient temperature on the bronchodilatation produced by terbutaline delivered from a chlorofluorocarbon pressurized metered dose inhaler (pMDl) compared to a multi‐dose dry powder inhaler (DPI).
Fourteen stable asthmatics were studied on two consecutive days.
On day 1, after measuring FEV1 at room temperature (22 °C), each patient was randomized to receive 500 μg of terbutaline delivered from pMDI or DPI stored for 24 h at 22 °C with FEV1 recorded 20 min post‐dose; then, patients were placed in a chamber at − 10 °C, and after obtaining FEV1, each patient received 500 μg of terbutaline delivered from pMDI or DPI (same formulation as previously administered) stored for 24 h at − 10 °C, and FEV1 was obtained 20 min post‐dose.
On day 2, a similar protocol was followed but each patient received terbutaline as the alternative to the formulation administered on day 1.
Pairwise comparisons of the FEV1 (% predicted) values obtained on day 1 and day 2 at 22 °C and − 10 °C (pre‐dose) showed no significant differences.
Similar bronchodilatations were observed for terbutaline DPI administration at 22 °C and − 10 °C (24.
85 ± 11.
72 and 20.
08 ± 6.
27 % increase of FEV1; P>0.
05).
By contrast, the bronchodilatation obtained for terbutaline pMDI at 22 °C (21.
07 ± 8.
55% increase in FEV1) was not reproduced at − 10 °C (0.
72 ± 2.
84%; P < 0.
05 from 22 °C).
In five asthmatics a cumulative dose‐response curve for terbutaline pMDI was obtained.
This part of the study showed that a higher dose of terbutaline pMDI was necessary at − 10 °C to obtain a bronchodilator response (10.
04 ± 6.
75% increase of FEV1 after 2 000 μg) that remained lower than the bronchodilatation for 500 μg terbutaline pMDI at − 10 °C.
In conclusion, the clinical effectiveness of terbutaline delivered from chlorofluorocarbon pMDIs is compromised by cold storage while DPIs are not affected.
Related Results
Metered-Dose Inhalers for Medical Cannabis Use
Metered-Dose Inhalers for Medical Cannabis Use
Limited evidence of the clinical effectiveness of metered-dose inhalers for medical cannabis is available from patients who were prior users of medical cannabis (primarily by smoki...
Does Theophylline Potentiate Inhaled β2‐Agonists?
Does Theophylline Potentiate Inhaled β2‐Agonists?
The influence of pretreatment with equipotent bronchodilating doses of intravenous theophyllamine and inhaled terbutaline on the effect of five terbutaline inhalations was investig...
Terbutaline and Ephedrine in Asthmatic Children
Terbutaline and Ephedrine in Asthmatic Children
The effects of terbutaline, ephedrine, and placebo on the cardiovascular and pulmonary systems have been compared in 24 asthmatic children. Ephedrine and terbutaline were both foun...
Stereoselective sulfation of terbutaline by the rat liver cytosol: evaluation of experimental approaches
Stereoselective sulfation of terbutaline by the rat liver cytosol: evaluation of experimental approaches
AbstractLittle is known about the stereochemistry of sulfation of chiral phenolic drugs. In this study we examined several in vitro approaches to this question, using (+)‐, (−)‐, o...
Selectivity of Bevantolol Hydrochloride, a β‐Adrenoceptor Antagonist, in Asthmatic Patients
Selectivity of Bevantolol Hydrochloride, a β‐Adrenoceptor Antagonist, in Asthmatic Patients
Bevantolol hydrochloride, a new β‐adrenoceptor antagonist, has been shown to be cardioselective in animals. To evaluate its selectivity in humans, a double‐blind, crossover study w...
Introducing a new national tool to monitor the carbon footprint of inhalers
Introducing a new national tool to monitor the carbon footprint of inhalers
Abstract
Introduction
The Welsh Government launched its National Health Service (NHS) Wales decarbonisation strategic delivery p...
Assessment of adherence to inhalers in asthmatics
Assessment of adherence to inhalers in asthmatics
Background:
Asthma is a chronic disorder which affects the quality of life and causes significant morbidity when uncontrolled. Good control of asthma has now become pos...
Impact of multiple-dose versus single-dose inhaler devices on COPD patients’ persistence with long-acting β2-agonists: a dispensing database analysis
Impact of multiple-dose versus single-dose inhaler devices on COPD patients’ persistence with long-acting β2-agonists: a dispensing database analysis
Abstract
Background:
With a growing availability of different devices and types of medication, additional evidence is required to assist clinicians ...

