Javascript must be enabled to continue!
Effects of Personal Protective Equipment on Spinal Column Loads From Underbody Blast Loading
View through CrossRef
Abstract
Combat-related spine injuries from improvised explosive devices are attributed to vertical loading transmitted from the seat to the pelvis to the torso and head-neck regions. The presence of personal protective equipment (PPE) adds to the weight of the torso, influencing the load transmission within the vertebral column. In this study, a detailed mid-size male finite element model from the Global Human Body Models Consortium was used to investigate the effect of PPE on spine kinematics, forces, and moments along the vertebral column. The model was positioned on a rigid seat, such that the posture represented an upright seated soldier. Once positioned, the model was updated with PPE. The models, with and without PPE were simulated under two high acceleration vertical loading pulses and the spine accelerations, forces and moments were investigated. The PPE increased the spinal loads, with reduced time to peak. The presence of PPE increased forces in the cervical and thoracic spines up to 14% and 9%, while it decreased the lumbar spine forces up to 7%. PPE increased cervical spine extension moment up to 104%, thoracic spine flexion moment up to 14%, and decreased the lumbar spine flexion moment up to 11%. The increase in thoracic spine compressive forces and flexion moments due to PPE suggest increased risk of injury in compression-flexion, such as anterior or burst fractures of the thoracic vertebrae with or without the distraction of posterior elements/ligaments. Whereas, the PPE may be effective in reducing the injury in lumbar spine, with reduced forces and moments. The pulse variation showed that the seat velocity along with the acceleration influence the spine kinematics and further parametric studies are needed to understand the effectiveness of PPE for varying seat velocities/accelerations. Spinal accelerations peaked earlier with PPE; however, their peak and morphologies were unchanged. This study delineates the kinetics of the spine injury during underbody blast loading and the role of PPE on potential injuries and injury mechanisms based on forces and moments.
American Society of Mechanical Engineers
Title: Effects of Personal Protective Equipment on Spinal Column Loads From Underbody Blast Loading
Description:
Abstract
Combat-related spine injuries from improvised explosive devices are attributed to vertical loading transmitted from the seat to the pelvis to the torso and head-neck regions.
The presence of personal protective equipment (PPE) adds to the weight of the torso, influencing the load transmission within the vertebral column.
In this study, a detailed mid-size male finite element model from the Global Human Body Models Consortium was used to investigate the effect of PPE on spine kinematics, forces, and moments along the vertebral column.
The model was positioned on a rigid seat, such that the posture represented an upright seated soldier.
Once positioned, the model was updated with PPE.
The models, with and without PPE were simulated under two high acceleration vertical loading pulses and the spine accelerations, forces and moments were investigated.
The PPE increased the spinal loads, with reduced time to peak.
The presence of PPE increased forces in the cervical and thoracic spines up to 14% and 9%, while it decreased the lumbar spine forces up to 7%.
PPE increased cervical spine extension moment up to 104%, thoracic spine flexion moment up to 14%, and decreased the lumbar spine flexion moment up to 11%.
The increase in thoracic spine compressive forces and flexion moments due to PPE suggest increased risk of injury in compression-flexion, such as anterior or burst fractures of the thoracic vertebrae with or without the distraction of posterior elements/ligaments.
Whereas, the PPE may be effective in reducing the injury in lumbar spine, with reduced forces and moments.
The pulse variation showed that the seat velocity along with the acceleration influence the spine kinematics and further parametric studies are needed to understand the effectiveness of PPE for varying seat velocities/accelerations.
Spinal accelerations peaked earlier with PPE; however, their peak and morphologies were unchanged.
This study delineates the kinetics of the spine injury during underbody blast loading and the role of PPE on potential injuries and injury mechanisms based on forces and moments.
Related Results
Numerical simulation of progressive collapse of structures under blast loads
Numerical simulation of progressive collapse of structures under blast loads
The growing need for blast-resistant designs in structural engineering is driven by the rising threat of terrorism, accidental explosions, and the significant risk of progressive c...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Damage response of ECC plates under different loading sequences of blast and fragment
Damage response of ECC plates under different loading sequences of blast and fragment
This study numerically investigated the damage response of ECC plates with different thicknesses subjected to blast and fragment loading under different sequential loading conditio...
Performance of the laminated glass systems under static and blast pressure loading
Performance of the laminated glass systems under static and blast pressure loading
[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] The increase of explosions threats toward civilian targets has raised concerns about a building's safety. Lam...
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
In this thesis, the effect of several important parameters on the behaviour and bearing capacity of multi-drum stone columns loaded by short-term static loads and earthquakes was i...
Lectin C gene analysis v1
Lectin C gene analysis v1
Mammalian Tissue Total RNA Purification Protocol by GeneJET RNA Purification Kit (Thermo Scientific, USA) Before starting: • Supplement the required amount of Lysis Buffer with β-...
Peak Particle Velocity for Blasting Rock Modeling
Peak Particle Velocity for Blasting Rock Modeling
ABSTRACT
Blasting mechanisms are a complex coupling of the rock mass properties and the explosive detonation performance as well as the blast design parameters. B...
The organization of spinal motor neurons in a monotreme is consistent with a six‐region schema of the mammalian spinal cord
The organization of spinal motor neurons in a monotreme is consistent with a six‐region schema of the mammalian spinal cord
AbstractThe motor neurons in the spinal cord of an echidna (Tachyglossus aculeatus) have been mapped in Nissl‐stained sections from spinal cord segments defined by spinal nerve ana...

