APPLICABILITY OF A COMMERCIALLY AVAILABLE ACTIVE EXTREMITY DOSE-RATE METER TO EYE LENS DOSE MONITORING
View through CrossRef
Abstract
A commercially available active extremity dosemeter is a promising candidate for medical staff aid individual monitoring of the eye lens. We investigated the applicability of the newly developed active extremity dosemeter, which uses a low-energy photon probe, to eye lens dose monitoring by performing a complete characterization of the dosemeters. Performance tests revealed that the active extremity dosemeter would overestimate personal dose equivalent, Hp(3), when the probe is worn close to the lens of the eye of a medial worker without any improvement in the response. Introducing an appropriate filter into the probe for low-energy photon has proven to improve the response. The dosemeter then satisfies the criteria of the personal dosemeter for eye lens dosimetry and can be applicable to individual monitoring of eye lens dose. This article also discusses the applicability of the dosemeter to area monitoring for decision making regarding additional monitoring of the eye lens and the extremities.
Oxford University Press (OUP)
Title: APPLICABILITY OF A COMMERCIALLY AVAILABLE ACTIVE EXTREMITY DOSE-RATE METER TO EYE LENS DOSE MONITORING
Description:
Abstract
A commercially available active extremity dosemeter is a promising candidate for medical staff aid individual monitoring of the eye lens.
We investigated the applicability of the newly developed active extremity dosemeter, which uses a low-energy photon probe, to eye lens dose monitoring by performing a complete characterization of the dosemeters.
Performance tests revealed that the active extremity dosemeter would overestimate personal dose equivalent, Hp(3), when the probe is worn close to the lens of the eye of a medial worker without any improvement in the response.
Introducing an appropriate filter into the probe for low-energy photon has proven to improve the response.
The dosemeter then satisfies the criteria of the personal dosemeter for eye lens dosimetry and can be applicable to individual monitoring of eye lens dose.
This article also discusses the applicability of the dosemeter to area monitoring for decision making regarding additional monitoring of the eye lens and the extremities.
Related Results
Eye lens dose measurement in patients during brain arteriovenous malformation interventional neuro-radiology procedure
Eye lens dose measurement in patients during brain arteriovenous malformation interventional neuro-radiology procedure
Brain arteriovenous malformation (AVM) interventional neuroradiology (INR) is a complicated procedure which the patients may receive the high radiation dose exceeding the threshold...
Comparative Clinical Performance of Rigid versus Soft Hyper Dk Contact Lenses Used for Continuous Wear
Comparative Clinical Performance of Rigid versus Soft Hyper Dk Contact Lenses Used for Continuous Wear
ABSTRACT
Purpose.
The purpose of this study is to investigate the comparative clinical performance of two hyper Dk contac...
Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens
Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens
Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommoda...
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Introduction. The structural approach to studying the mechanism of accommodation and its age-related changes focuses on analyzing morphometric parameters (size, shape, and position...
Cataract, glaucoma, possible Marfan syndrome, and conception aspirations: January consultation #1
Cataract, glaucoma, possible Marfan syndrome, and conception aspirations: January consultation #1
A 36-year-old highly myopic woman was referred for management of both cataract and glaucoma. Her ocular history included retinal detachment repair in each eye, 9 years earlier in t...
Molecular Genetics of Cataract
Molecular Genetics of Cataract
Abstract
Cataract can be defined as any opacity or cloudiness of the crystalline lens. When there is significant variation of the refractive ind...
Isolated Upper Extremity Compartment Syndrome: A Case of Rhabdomyolysis-induced Myoglobinuria and Acute Kidney Injury after Opioid Overdose
Isolated Upper Extremity Compartment Syndrome: A Case of Rhabdomyolysis-induced Myoglobinuria and Acute Kidney Injury after Opioid Overdose
Introduction: The association between rhabdomyolysis secondary to traumatic crush injuries and the resultant acute kidney injury has been well described [1]. The pathway of opioid ...
Penggunaan Lensa Kontak untuk Astigmatisma Paska Keratoplasti
Penggunaan Lensa Kontak untuk Astigmatisma Paska Keratoplasti
Background: Fitting Contact Lenses for post penetrating keratoplasty patiens can be a great challenges to contact lens practitioner. Despite advances in surgical techniques for pen...