Development of a Medical Phantom to Evaluate the Function of Low Dose 3D MDCT

View through CrossRef
Background/Objectives: Low dose radiation-based CT imaging is a technology that dramatically improves the information on borders between similar substances but with difference in density. The findings will serve as basic data in developing a CT phantom dedicated for X-ray phase differential imaging.Method/Statistical Analysis: To evaluate the benefits of a phantom for low dose 3D MDCT, SOMATOM Definition AS? (Siemens, Germany) CT scanner that produces 128 slices of images with one rotation was used. The auto-exposure condition (AEC) was applied as it is frequently used in clinical settings for high dose CT. After the image was acquired, a qualitative analysis was conducted to verify the practical use in a clinical setting.Findings: In order to evaluate the images acquired from the in-house produced medical phantom and the resolution in the image space, the phantom must be made of substances that have a similar actual atomic number as water. It is practical to produce the phantom for 3D CT by mixing a pure liquid and powder. The absorption, dispersion and phase differential images acquired through the low dose X-ray device were analyzed on a 5 point Likert scale. The absorption image scored 4.3 points for liquid form and 3.50 points for powder form. Both the dispersion image and the phase differential image scored 3.00 points for the liquid form and 4.50 points for the powder form, indicating that the liquid form produces better quality images in the absorption image, while the powder form produces better images in dispersion or phase differential images. The differences were statistically significant (p<0.05).Improvements/Applications: The findings show that for dispersion and phase differential images, compared to the absorption images, substances in powder form rather than liquid form are conducive to better images. These findings are expected to be of use in the field of medical imaging to produce images with high diagnostic value using low dose radiation.
Institute of Medico-legal Publications Private Limited
Title: Development of a Medical Phantom to Evaluate the Function of Low Dose 3D MDCT
Description:
Background/Objectives: Low dose radiation-based CT imaging is a technology that dramatically improves the information on borders between similar substances but with difference in density.
The findings will serve as basic data in developing a CT phantom dedicated for X-ray phase differential imaging.
Method/Statistical Analysis: To evaluate the benefits of a phantom for low dose 3D MDCT, SOMATOM Definition AS? (Siemens, Germany) CT scanner that produces 128 slices of images with one rotation was used.
The auto-exposure condition (AEC) was applied as it is frequently used in clinical settings for high dose CT.
After the image was acquired, a qualitative analysis was conducted to verify the practical use in a clinical setting.
Findings: In order to evaluate the images acquired from the in-house produced medical phantom and the resolution in the image space, the phantom must be made of substances that have a similar actual atomic number as water.
It is practical to produce the phantom for 3D CT by mixing a pure liquid and powder.
The absorption, dispersion and phase differential images acquired through the low dose X-ray device were analyzed on a 5 point Likert scale.
The absorption image scored 4.
3 points for liquid form and 3.
50 points for powder form.
Both the dispersion image and the phase differential image scored 3.
00 points for the liquid form and 4.
50 points for the powder form, indicating that the liquid form produces better quality images in the absorption image, while the powder form produces better images in dispersion or phase differential images.
The differences were statistically significant (p<0.
05).
Improvements/Applications: The findings show that for dispersion and phase differential images, compared to the absorption images, substances in powder form rather than liquid form are conducive to better images.
These findings are expected to be of use in the field of medical imaging to produce images with high diagnostic value using low dose radiation.

Related Results

CTdBem &ndash; A New Protocol for Ultra Low Radiation Dose MDCT
CTdBem &ndash; A New Protocol for Ultra Low Radiation Dose MDCT
This study describes a novel method of obtaining low-dose computed tomography (CT) scans followed by imaging postprocessing that provides diagnostic quality to such low-dose exams....
Body image and perception among adults with and without phantom limb pain
Body image and perception among adults with and without phantom limb pain
AbstractBackgroundFollowing lower‐limb amputation, phantom limb pain (i.e., pain perceived as coming from the amputated portion of the limb) is common. Phantom limb pain may be ass...
MDCT OF ABDOMINAL WALL LUMBAR HERNIAS
MDCT OF ABDOMINAL WALL LUMBAR HERNIAS
Purpose:To review the anatomical landmarks of the abdominal wall lumbar region and its normal appearance on multidetector computed tomography (MDCT) and to briefly describe the MDC...
Role of multi-detector computed tomography (MDCT) in management of post percutaneous nephrolithotomy (PCNL) bleeding
Role of multi-detector computed tomography (MDCT) in management of post percutaneous nephrolithotomy (PCNL) bleeding
Objective: To evaluate the role of multidetector computerized tomography (MDCT) angiography in post percutaneous nephrolithotomy (PCNL) bleed and compare findin...
MULTIDETECTOR CT IN EMERGENCY RADIOLOGY: ACUTE AND GENERALIZED NON-TRAUMATIC ABDOMINAL PAIN
MULTIDETECTOR CT IN EMERGENCY RADIOLOGY: ACUTE AND GENERALIZED NON-TRAUMATIC ABDOMINAL PAIN
Background: Acute generalized non-traumatic abdominal pain is one of the most common causes of emergency department visits and presents a significant diagnostic challenge due to it...
Imaging in Local Staging of Gastric Cancer: A Systematic Review
Imaging in Local Staging of Gastric Cancer: A Systematic Review
Purpose Endoscopic ultrasound (EUS) has been established as the diagnostic modality of choice in local (T) staging of gastric cancer. Multidetector row computed tomography (MDCT) a...
Abstract 6108: Cardiac 64-slice Multidetector Computerized Tomography in the Management of Prosthetic Heart Valve Obstruction
Abstract 6108: Cardiac 64-slice Multidetector Computerized Tomography in the Management of Prosthetic Heart Valve Obstruction
Differentiation of pannus (P) and thrombus (THR) in prosthetic heart valve obstruction (PHVO) is still a confusive state at the present cardiological practise. Transesophageal echo...

Back to Top